Simple method for estimating regurgitant volume with use of a single radius for measuring proximal isovelocity surface area: An in vitro study of simulated mitral regurgitation

被引:5
|
作者
Tokushima, T
Reid, CL
Hata, A
Gardin, JM
机构
[1] Saga Med Sch, Div Cardiol, Saga, Japan
[2] Univ Calif Irvine, Div Cardiol, Irvine, CA USA
[3] Univ Calif Irvine, Div Cardiol, Irvine, CA USA
[4] Tokyo Med & Dent Univ, Dept Internal Med, Tokyo, Japan
关键词
D O I
10.1067/mje.2001.108198
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The proximal isovelocity surface area (PISA) color Doppler method with use of a hemielliptic formula is reported to be accurate for quantitating regurgitant volume (RV). However, this formula ideally requires the measurement of 2 or 3 radii and therefore is not widely used clinically. The purpose of this in vitro study was to derive a simple PISA formula for estimating RV with use of a single radius axial to the valve orifice and to compare it with the clinically used single-radius hemispherical formula (2 x pi x R-2 x AV x TVI/Vp), where AV is the apparent color Doppler aliasing velocity, R is the PISA. color Doppler aliasing radius, TVI is time-velocity integral of the jet by continuous wave Doppler, and Vp is the peak velocity of the jet by continuous wave Doppler. Pulsatile flow studies were performed across a convex curvilinear surface, which more closely approximates the shape of the mitral valve than does a planar surface. Pulse rates (60 to 80 bpm), peak now velocities (4.0 to 6.0 m/s), and regurgitant orifice areas (0.2 to 1.0 cm(2))were varied to simulate mitral regurgitation. The AVs were varied from 11 to 39 cm/s, and a single PISA aliasing radius was measured at each AV. Excellent linear correlations were obtained between the PISA radius and the actual RV measured with use of a beaker (r = 0.94 to 0.97, P < .0001). A series of simplified formulas was derived from the regression line of the PISA radius versus the RV. For example, with an AV of 21 cm/s, RV was estimated by a simplified PISA formula (where RV [mL] = 10 x R [mm] - 30) with are accuracy of 3.3 +/- 6.3 mL versus -20.3 +/- 8.7 mt for the standard single-radius PISA method (P < .0001). By using the standard single-radius hemispherical PISA formula, RV was underestimated if the radius was <20 mm. By using simplified regression equations, the PISA radius accurately estimated RV at a PISA radius <20 mm. Clinical studies are necessary to validate this concept.
引用
收藏
页码:104 / 113
页数:10
相关论文
共 50 条
  • [41] Comparison of orifice area by transthoracic three-dimensional Doppler echocardiography versus proximal isovelocity surface area (PISA) method for assessment of mitral regurgitation
    Iwakura, K
    Ito, H
    Kawano, S
    Okamura, A
    Kurotobi, T
    Date, M
    Inoue, K
    Fujii, K
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (11): : 1630 - 1637
  • [42] CHANGES IN EFFECTIVE REGURGITANT ORIFICE THROUGHOUT SYSTOLE IN PATIENTS WITH MITRAL-VALVE PROLAPSE - A CLINICAL-STUDY USING THE PROXIMAL ISOVELOCITY SURFACE-AREA METHOD
    ENRIQUEZSARANO, M
    SINAK, LJ
    TAJIK, AJ
    BAILEY, KR
    SEWARD, JB
    CIRCULATION, 1995, 92 (10) : 2951 - 2958
  • [43] Leaning Too Much on the Power of Proximal Isovelocity Surface Area? Don't Forget the Volumetric Method for Quantifying Functional Mitral Regurgitation
    Hu, Ray
    Chen, Tiffany
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2021, 10 (11):
  • [44] Direct Measurement of Proximal Isovelocity Surface Area by Real-Time Three-Dimensional Color Doppler for Quantitation of Aortic Regurgitant Volume: An In Vitro Validation
    Pirat, Bahar
    Little, Stephen H.
    Igo, Stephen R.
    McCulloch, Marti
    Nose, Yukihiko
    Hartley, Craig J.
    Zoghbi, William A.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (03) : 306 - 313
  • [45] In vitro validation of real-time three-dimensional color Doppler echocardiography for direct measurement of proximal isovelocity surface area in mitral regurgitation
    Little, Stephen H.
    Igo, Stephen R.
    Pirat, Bahar
    McCulloch, Marti
    Hartley, Craig J.
    Nose, Yukihiko
    Zoghbi, William A.
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (10): : 1440 - 1447
  • [46] Using multidirectional velocity mapping to improve accuracy of the proximal isovelocity surface area method of quantifying atrioventricular valve regurgitation: An in vitro magnetic resonance imaging study
    Whitehead, Kevin K.
    Harris, Matthew A.
    Gillespie, Matthew J.
    Fogel, Mark A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A164 - A164
  • [48] QUANTITATIVE ASSESSMENT OF MITRAL REGURGITATION IN PATIENTS WITH MULTIPLE REGURGITANT JETS USING PROXIMAL ISOVELOCITY SURFACE AREA: HEAD TO HEAD COMPARISON BETWEEN TWO-VERSUS THREE-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    Hyodo, Eiichi
    Iwata, Shinichi
    Tugcu, Aylin
    Di Tullio, Marco R.
    Muro, Takashi
    Yoshiyama, Minoru
    Homma, Shunichi
    Gillam, Linda D.
    Hahn, Rebecca T.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E761 - E761
  • [49] Evaluation of mitral regurgitation severity by proximal isovelocity surface area (PISA) method using cardiac magnetic resonance imaging 3D velocity vectors
    Lessick, J.
    Gorodisky, L.
    Porat, M.
    EUROPEAN HEART JOURNAL, 2014, 35 : 121 - 121
  • [50] DOPPLER COLOR FLOW PROXIMAL ISOVELOCITY SURFACE-AREA METHOD FOR ESTIMATING VOLUME FLOW-RATE - EFFECTS OF ORIFICE SHAPE AND MACHINE FACTORS
    UTSUNOMIYA, T
    OGAWA, T
    DOSHI, R
    PATEL, D
    QUAN, M
    HENRY, WL
    GARDIN, JM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (05) : 1103 - 1111