Simple method for estimating regurgitant volume with use of a single radius for measuring proximal isovelocity surface area: An in vitro study of simulated mitral regurgitation

被引:5
|
作者
Tokushima, T
Reid, CL
Hata, A
Gardin, JM
机构
[1] Saga Med Sch, Div Cardiol, Saga, Japan
[2] Univ Calif Irvine, Div Cardiol, Irvine, CA USA
[3] Univ Calif Irvine, Div Cardiol, Irvine, CA USA
[4] Tokyo Med & Dent Univ, Dept Internal Med, Tokyo, Japan
关键词
D O I
10.1067/mje.2001.108198
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The proximal isovelocity surface area (PISA) color Doppler method with use of a hemielliptic formula is reported to be accurate for quantitating regurgitant volume (RV). However, this formula ideally requires the measurement of 2 or 3 radii and therefore is not widely used clinically. The purpose of this in vitro study was to derive a simple PISA formula for estimating RV with use of a single radius axial to the valve orifice and to compare it with the clinically used single-radius hemispherical formula (2 x pi x R-2 x AV x TVI/Vp), where AV is the apparent color Doppler aliasing velocity, R is the PISA. color Doppler aliasing radius, TVI is time-velocity integral of the jet by continuous wave Doppler, and Vp is the peak velocity of the jet by continuous wave Doppler. Pulsatile flow studies were performed across a convex curvilinear surface, which more closely approximates the shape of the mitral valve than does a planar surface. Pulse rates (60 to 80 bpm), peak now velocities (4.0 to 6.0 m/s), and regurgitant orifice areas (0.2 to 1.0 cm(2))were varied to simulate mitral regurgitation. The AVs were varied from 11 to 39 cm/s, and a single PISA aliasing radius was measured at each AV. Excellent linear correlations were obtained between the PISA radius and the actual RV measured with use of a beaker (r = 0.94 to 0.97, P < .0001). A series of simplified formulas was derived from the regression line of the PISA radius versus the RV. For example, with an AV of 21 cm/s, RV was estimated by a simplified PISA formula (where RV [mL] = 10 x R [mm] - 30) with are accuracy of 3.3 +/- 6.3 mL versus -20.3 +/- 8.7 mt for the standard single-radius PISA method (P < .0001). By using the standard single-radius hemispherical PISA formula, RV was underestimated if the radius was <20 mm. By using simplified regression equations, the PISA radius accurately estimated RV at a PISA radius <20 mm. Clinical studies are necessary to validate this concept.
引用
收藏
页码:104 / 113
页数:10
相关论文
共 50 条
  • [31] Three-dimensional color Doppler echocardiography for direct measurement of mitral regurgitation proximal isovelocity surface area:: An in vitro validation
    Little, SH
    Igo, SR
    Pirat, B
    McCulloch, ML
    Hartley, CJ
    Nosé, Y
    Zoghbi, WA
    CIRCULATION, 2005, 112 (17) : U601 - U602
  • [33] Usefulness of the proximal isovelocity surface area method for quantification of the severity of aortic regurgitation in patients with eccentric regurgitant jets: Comparison with cardiac magnetic resonance
    Pouleur, Anne-Catherine M.
    de Waroux, Jean-Benoit le Polain
    Pasquet, Agnes
    Gerber, Bernhard
    Vanoverschelde, Jean-Louis J.
    CIRCULATION, 2006, 114 (18) : 759 - 759
  • [34] CAN PROXIMAL ISOVELOCITY SURFACE-AREA METHOD CALCULATE STENOTIC MITRAL-VALVE AREA IN PATIENTS WITH ASSOCIATED AORTIC REGURGITATION
    IKAWA, H
    HABU, H
    HIRANO, Y
    NAITOU, T
    SASAKI, T
    KATORI, R
    CIRCULATION, 1993, 88 (04) : 450 - 450
  • [35] Hemielliptic proximal isovelocity surface area method modified for clinical application - More accurate quantification of mitral regurgitation in Doppler echocardiography
    Fujii, H
    Kibira, S
    Izumi, C
    Saito, T
    Ryabikov, A
    Miura, M
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2001, 65 (09): : 820 - 826
  • [36] Direct Measurement of Proximal Isovelocity Surface Area by Single-Beat Three-Dimensional Color Doppler Echocardiography in Mitral Regurgitation: A Validation Study
    Alberto de Agustin, Jose
    Marcos-Alberca, Pedro
    Fernandez-Golfin, Covadonga
    Goncalves, Alexandra
    Feltes, Gisela
    Javier Nunez-Gil, Ivan
    Almeria, Carlos
    Luis Rodrigo, Jose
    Perez de Isla, Leopoldo
    Macaya, Carlos
    Zamorano, Jose
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (08) : 815 - 823
  • [37] Direct measurement of proximal isovelocity surface area by single-beat three-dimensional color doppler echocardiography in mitral regurgitation
    Viliani, D.
    De Agustin Loeches, J. A.
    Mejia, H.
    Marcos, P.
    Gomez De Diego, J. J.
    Luaces, M.
    Rodrigo, J. L.
    Garcia-Fernandez, M. A.
    Macaya, C.
    De Isla, L. Perez
    EUROPEAN HEART JOURNAL, 2014, 35 : 123 - 123
  • [38] DOPPLER COLOR FLOW PROXIMAL ISOVELOCITY SURFACE-AREA (PISA) - AN ALTERNATIVE METHOD FOR ESTIMATING VOLUME FLOW ACROSS NARROWED ORIFICES, REGURGITANT VALVES, AND INTRACARDIAC SHUNT LESIONS
    GARDIN, JM
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1992, 9 (01): : 39 - 42
  • [39] ACCURACY OF REGURGITANT VOLUME CALCULATION USING COLOR DOPPLER ZERO-BASE-LINE SHIFT PROXIMAL ISOVELOCITY SURFACE-AREA METHOD
    UTSUNOMIYA, T
    DOSHI, R
    PATEL, D
    MEHTA, K
    NGUYEN, D
    GARDIN, JM
    CIRCULATION, 1990, 82 (04) : 553 - 553
  • [40] A semiautomated objective technique for applying the proximal isovelocity surface area method to quantitate mitral regurgitation: Clinical studies with the digital flow map
    Mele, D
    Schwammenthal, E
    Torp, H
    Nesta, F
    Pedini, I
    Vandervoort, P
    Alboni, P
    Levine, RA
    AMERICAN HEART JOURNAL, 2001, 141 (04) : 653 - 660