Real-Time Electrochemical Detection of Uric Acid, Dopamine and Ascorbic Acid by Heme Directly Modified Carbon Electrode

被引:8
|
作者
Feng, Xiao-Zhen [1 ,2 ]
Su, Xiaorui [2 ]
Ferranco, Annaleizle [3 ]
Chen, Zhencheng [2 ]
Han, Guo-Cheng [2 ]
Jiang, Zhiliang [1 ]
Kraatz, Heinz-Bernhard [3 ]
机构
[1] Guangxi Norma Univ, Key Lab Ecol Rare & Endangered Species & Environm, Minist Educ, Guangxi Key Lab Environm Pollut Control Theory &, Guilin 541004, Peoples R China
[2] Guilin Univ Elect Technol, Sch Life & Environm Sci, Guilin 541004, Peoples R China
[3] Univ Toronto Scarborough, Dept Phys & Environm Sci, Toronto, ON M1C 1A4, Canada
基金
中国国家自然科学基金;
关键词
Biomolecules; Simultaneous Detection; Electrocatalytic Response; Carbon Electrode; Heme; GRAPHENE QUANTUM DOTS; VOLTAMMETRIC DETERMINATION; BIOSENSING PLATFORM; PASTE ELECTRODE; SENSOR; NANOPARTICLES; NANOTUBE; NANOCOMPOSITES; EPINEPHRINE; TRYPTOPHAN;
D O I
10.1166/jbn.2020.2879
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Several simple electrochemical sensors were designed for three analytes, uric acid (UA), dopamine (DA) and ascorbic acid (AA) detection via electrolytic deposition of three functional materials heme, Fc(Cys)(2) and Fc-ECG onto glassy carbon electrodes (GCEs) without other medium. Characterization of the modified GCEs was conducted using SEM, TEM and DPV methods. Results showed that the heme/GCE demonstrated notable electro-catalytic capabilities, towards DA, AA, and UA oxidation in a solution of phosphate buffer. The current signals of DPV technique for three analytes shown up three defined oxidated peaks, the peak potential differences was 192 mV for AA and DA, and 142 mV for DA and UA. Under optimal conditions, it can be obtained linear responses for AA, DA and UA in the following concentration ranges: 10 to 50, 5 to 20, and 2.5 to 20 mu mol. L-1, and the limits of detection was calculated as 0.76, 0.50 and 0.63 mu mol. L-1, respectively. The results demonstrated that the heme directly modified GCE was a well-suited electrochemical sensor for determining UA, DA and AA in actual samples.
引用
收藏
页码:29 / 39
页数:11
相关论文
共 50 条
  • [21] Electrochemical detection of uric acid and ascorbic acid: Application in serum
    Choukairi, M.
    Bouchta, D.
    Bounab, L.
    Ben Atyah, M.
    Elkhamlichi, R.
    Chaouket, F.
    Raissouni, I.
    Rodriguez, I. N.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 758 : 117 - 124
  • [22] The influence of uric and ascorbic acid on the electrochemical detection of dopamine using graphene-modified electrodes
    Pruneanu, Stela
    Biris, Alexandru R.
    Pogacean, Florina
    Socaci, Crina
    Coros, Maria
    Rosu, Marcela Corina
    Watanabe, Fumiya
    Biris, Alexandru S.
    ELECTROCHIMICA ACTA, 2015, 154 : 197 - 204
  • [23] Response of SWCNTs/KPG5-modified carbon electrode on dopamine, uric acid and ascorbic acid
    Rofiansyah, Ardi
    Tominaga, Masato
    Kurniawan, Fredy
    INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING RESEARCH AND APPLICATION, 2019, 494
  • [24] Carbon nanofiber modified with reduced graphite oxide for detection of ascorbic acid, dopamine, and uric acid
    Aryal, Krishna Prasad
    Jeong, Hae Kyung
    CHEMICAL PHYSICS LETTERS, 2020, 739
  • [25] Simultaneous determination of dopamine, ascorbic acid, and uric acid using helical carbon nanotubes modified electrode
    Cui, Rongjing
    Wang, Xueying
    Zhang, Genhua
    Wang, Chen
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 1139 - 1143
  • [26] Poly(thionine)-modified GC electrode for simultaneous detection of dopamine and uric acid in the presence of ascorbic acid
    Yuan, Yong
    Ahammad, A. J. Saleh
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    1883, Korean Chemical Society, Seoul, 135-703, South Korea (29) : 1883 - 1884
  • [27] Simultaneous electrochemical determination of dopamine, ascorbic acid and uric acid using poly(acid chrome blue K) modified glassy carbon electrode
    Zhang, Rui
    Jin, Gen-Di
    Chen, Da
    Hu, Xiao-Ya
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (01): : 174 - 181
  • [28] Poly(thionine)-modified GC Electrode for Simultaneous Detection of Dopamine and Uric Acid in the Presence of Ascorbic Acid
    Yuan, Yong
    Ahammad, A. J. Saleh
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2008, 29 (10) : 1883 - 1884
  • [29] Simultaneous Electrochemical Detection of Dopamine and Ascorbic Acid Using an Iron Oxide/Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Peik-See, Teo
    Pandikumar, Alagarsamy
    Nay-Ming, Huang
    Hong-Ngee, Lim
    Sulaiman, Yusran
    SENSORS, 2014, 14 (08): : 15227 - 15243
  • [30] A Poly(trypan blue)-Modified Anodized Glassy Carbon Electrode for the Sensitive Detection of Dopamine in the Presence of Uric Acid and Ascorbic Acid
    Li, Xiao-Bo
    Rahman, Md. Mahbubur
    Ge, Chuang-Ye
    Xu, Guang-Ri
    Lee, Jae-Joon
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (02) : B34 - B39