Mixing performance of T, Y, and oriented Y-micromixers with spatially arranged outlet channel: evaluation with Villermaux/Dushman test reaction

被引:26
作者
Rahimi, Masoud [1 ]
Azimi, Neda [1 ]
Parsamogadam, Mohammad Amin [1 ]
Rahimi, Alireza [2 ]
Masahy, Mohammad Moein [3 ]
机构
[1] Razi Univ, Dept Chem Engn, CFD Res Ctr, Kermanshah, Iran
[2] Sharif Univ Technol, Dept Chem & Petr Engn, Tehran, Iran
[3] Ind Management Ctr Appl Sci & Technol, Kermanshah, Iran
来源
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS | 2017年 / 23卷 / 08期
关键词
TUBULAR SONOREACTOR; CHEMICAL-REACTIONS; REACTION SYSTEM; MICROCHANNELS; EFFICIENCY; ULTRASOUND; IODIDE; MICROPARTICLES; ENHANCEMENT; GEOMETRY;
D O I
10.1007/s00542-016-3118-6
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study aims to investigate the micromixing performance of three basic types of spatial shaped micromixers. New configurations of T, Y, and oriented Y-spatial mixers were designed with change in the angles of the confluence and the outlet channel to achieve the efficient micromixing. These micromixers offer advantages that are not attainable with the typical types of these mixers. Experimental tests were carried out in the laminar flow regime and the mixing efficiency was evaluated using Villermaux/Dushman test reaction. The geometries of the channels were cylindrical with the length of 30 mm and the diameter of 800 mu m. The experimental results show that the angle of outlet channel has a significant effect on the pressure drop and segregation index. Generally, the results reveal that at various feed flow rates the spatial shape of channels can lead to considerable improvement in micromixing performance. In all T, Y, and oriented Y-mixers, significant enhancement by increasing the confluence angle was also seen because the fluid elements were stretched and folded in the two inlet fluid interfaces. Furthermore, the micromixing time for the more efficient geometry of three shapes of microchannels was determined based on the incorporation model, which it was in the range of 0.001-0.1 s.
引用
收藏
页码:3117 / 3130
页数:14
相关论文
共 4 条
  • [1] Comparison of mixing performances of T, Y and arrow-shaped micromixers using Villermaux-Dushman protocol at low Reynolds number
    Okwundu, Onyeka S.
    Fuseini, Mohammed
    El-Shazly, Ahmed H.
    Elkady, Marwa F.
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2020, 85 (03) : 381 - 394
  • [2] Mixing Performance Evaluation for Commercially Available Micromixers Using Villermaux-Dushman Reaction Scheme with the Interaction by Exchange with the Mean Model
    Reckamp, Joseph M.
    Bindels, Ashira
    Duffield, Sophie
    Liu, Yangmu Chloe
    Bradford, Eric
    Ricci, Eric
    Susanne, Flavien
    Rutter, Andrew
    ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2017, 21 (06) : 816 - 820
  • [3] Mixing performance in T-shape microchannel at high flow rate for Villermaux-Dushman reaction
    Lv, Peng
    Zhang, Liangjing
    Srinivasakannan, C.
    Li, Shiwei
    He, Yuan
    Chen, Kaihua
    Yin, Shaohua
    MICROCHEMICAL JOURNAL, 2020, 155
  • [4] Investigation of mixing performance in a semi-active T-micromixer actuated by magnetic nanoparticles: Characterization via Villermaux-Dushman reaction
    Azimi, Neda
    Rahimi, Masoud
    Hosseini, Fardin
    Jafari, Omid
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2023, 101 (02) : 1055 - 1067