A Low-Intrusion Load and Efficiency Evaluation Method for In-Service Motors Using Vibration Tests With an Accelerometer

被引:19
作者
Zhang, He [1 ,2 ]
Zanchetta, Pericle [1 ]
Bradley, Keith J. [1 ]
Gerada, Chris
机构
[1] Univ Nottingham, Power Elect Machines & Control Grp, Nottingham NG7 2RD, England
[2] WRc Plc, Swindon SN5 8YF, Wilts, England
关键词
Energy and efficiency measurement; induction machines; industrial power system; vibration; ELECTRIC MOTORS;
D O I
10.1109/TIA.2010.2049550
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents a novel low-intrusion load and efficiency evaluation method for in-service induction motors based on vibration measurements. This method enhances the traditional vibration analysis by providing motor load and efficiency information in addition to the mechanical health information. The application is in multimotor plants, where individual motor monitoring is too expensive to implement yet where motor operating conditions need to be known to work at improved plant efficiency. The vibration signature of the machine, measured by an accelerometer and processed by fast Fourier transform (FFT) is used to extract frequencies defining shaft speed and the supply frequency. This data, in conjunction with the basic motor performance data, enables the determination of the actual load and indirectly, the efficiency which the motor is operating at. For motors supplied form a variable-speed drive (VSD), the loss segregation method is used to yield the motor losses indirectly and thus, the efficiency.
引用
收藏
页码:1341 / 1349
页数:9
相关论文
共 17 条
[1]  
Adamis MauriceL., 2001, ROTATING MACHINERY V
[2]   Assessment of nonintrusive motor efficiency estimators [J].
Agamloh, EB ;
Wallace, AK ;
von Jouanne, A ;
Anderson, KJ ;
Rooks, JA .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (01) :127-133
[3]  
Alger P., 1995, INDUCTION MACHINES T
[4]   Efficiency of electric motors under practical conditions [J].
Auinger, H .
POWER ENGINEERING JOURNAL, 2001, 15 (03) :163-167
[5]   International standards for the induction motor efficiency evaluation: A critical analysis of the stray-load loss determination [J].
Boglietti, A ;
Cavagnino, A ;
Lazzari, M ;
Pastorelli, M .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (05) :1294-1301
[6]  
Boyes W., 2002, INSTRUMENTATION REFE
[7]  
CAO W, 2006, IAS, V1, P441
[8]   An accurate low-cost method for determining electric motors' efficiency for the purpose of plant energy management [J].
El-Ibiary, Y .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (04) :1205-1210
[9]   AN FFT-BASED NOVEL-APPROACH TO NONINVASIVE SPEED MEASUREMENT IN INDUCTION-MOTOR DRIVES [J].
FERRAH, A ;
BRADLEY, KJ ;
ASHER, GM .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1992, 41 (06) :797-802
[10]   Practical approach for determining motor efficiency in the field using calculated and measured values [J].
Holmquist, JR ;
Rooks, JA ;
Richter, ME .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (01) :242-248