Optoacoustic imaging using thin polymer etalon

被引:77
作者
Ashkenazi, S [1 ]
Hou, Y [1 ]
Buma, T [1 ]
O'Donnell, M [1 ]
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
关键词
D O I
10.1063/1.1896085
中图分类号
O59 [应用物理学];
学科分类号
摘要
Optical detection of ultrasound is a promising technique for high frequency imaging arrays. Detection resolution approaches the optical resolution, which can be on the order of the optical wavelength. We describe here an optical technique for ultrasound detection based on a thin (10 mu m) Fabry-Perot etalon optimized for high resolution imaging. The signal to noise ratio (SNR) approaches that of an ideal piezoelectric transducer over a 100 MHz bandwidth. Array functionality is demonstrated by scanning a probe beam along a line. Thermoelastic excitation was applied to generate acoustic waves in a test phantom containing a single "pointlike" source. An image of the source was reconstructed using signals acquired from the etalon detector array. (C) 2005 American Institute of Physics.
引用
收藏
页码:1 / 3
页数:3
相关论文
共 20 条
  • [1] Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection
    Beard, PC
    Pérennès, F
    Mills, TN
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (06) : 1575 - 1582
  • [2] Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications
    Cannata, JM
    Ritter, TA
    Chen, WH
    Silverman, RH
    Shung, KK
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (11) : 1548 - 1557
  • [3] Accurate corneal thickness measurement using ultrasound
    Cao, PJ
    Chen, WH
    Karkhanis, N
    Shung, KK
    [J]. MEDICAL IMAGE 2002: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2002, 4687 : 430 - 437
  • [4] Crain K., 1995, Surface Mount Technology, V9, P50
  • [5] A new ultrasound instrument for in vivo microimaging of mice
    Foster, FS
    Zhang, MY
    Zhou, YQ
    Liu, G
    Mehi, J
    Cherin, E
    Harasiewicz, KA
    Starkoski, BG
    Zan, L
    Knapik, DA
    Adamson, SL
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (09) : 1165 - 1172
  • [6] Goertz DE, 2002, CANCER RES, V62, P6371
  • [7] High frequency ultrasound imaging with optical arrays
    Hamilton, JD
    O'Donnell, M
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (01) : 216 - 235
  • [8] High frequency optoacoustic arrays using etalon detection
    Hamilton, JD
    Buma, T
    Spisar, M
    O'Donnell, M
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (01) : 160 - 169
  • [9] HUTT DA, 2000, EL MAN TECHN S 2000, P191
  • [10] Two-dimensional photoacoustic imaging by use of Fourier-transform image reconstruction and a detector with an anisotropic response
    Köstli, KP
    Beard, PC
    [J]. APPLIED OPTICS, 2003, 42 (10) : 1899 - 1908