High-fidelity Human Patient Simulators Compared with Human Actors in an Unannounced Mass-Casualty Exercise

被引:15
作者
Schulz, Christian M. [1 ]
Skrzypczak, Matthias [1 ]
Raith, Stefan [2 ]
Hinzmann, Dominik [1 ]
Krautheim, Veronika [1 ]
Heuser, Fabian [1 ]
Mayer, Valentin [1 ]
Kreuzer, Christoph [1 ]
Himsl, Meike [1 ]
Holl, Michael [1 ]
Lipp, Christina [1 ]
Kochs, Eberhard F. [1 ]
Wagner, Klaus J. [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Anesthesiol, Ismaninger Str 22, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Clin Plast Surg & Hand Surg, Munich, Germany
关键词
disaster medicine; mass-casualty incident; patient simulation; triage;
D O I
10.1017/S1049023X14000223
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
High-fidelity simulators (HFSs) have been shown to prompt critical actions at a level equal to that of trained human actors (HAs) and increase perceived realism in intrahospital mass-casualty incident (MCI) exercises. For unannounced prehospital MCI exercises, however, no data are available about the feasibility of incorporating HFSs. This case report describes the integration of HFSs in such an unannounced prehospital MCI drill with HAs and provides data about the differences concerning triage, treatment, and transport of HFSs and HAs with identical injury patterns. For this purpose, 75 actors and four high-fidelity simulators were subdivided into nine groups defined by a specific injury pattern. Four HFSs and six HAs comprised a group suffering from traumatic brain injury and blunt abdominal trauma. Triage results, times for transport, and number of diagnostic and therapeutic tasks were recorded. Means were compared by t test or one-way ANOVA. Triage times and results did not differ between actors and simulators. The number of diagnostic (1.25, SD = 0.5 in simulators vs 3.5, SD = 1.05 in HAs; P =.010) and therapeutic tasks (2.0, SD = 1.6 in simulators vs 4.8, SD = 0.4 in HAs; P =.019) were significantly lower in simulators. Due to difficulties in treating and evacuating the casualties from the site of the accident in a timely manner, all simulators died. Possible causal factors and strategies are discussed, with the aim of increasing the utility of simulators in emergency medicine training.
引用
收藏
页码:176 / 182
页数:7
相关论文
共 12 条
[1]   European survey on training objectives in disaster medicine [J].
Delooz, Herman ;
Debacker, Michel ;
Moens, Guido ;
Johannik, Kristien .
EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2007, 14 (01) :25-31
[2]   Review of mannequin-based high-fidelity simulation in emergency medicine [J].
Fritz, Peter Z. ;
Gray, Tim ;
Flanagan, Brendan .
EMERGENCY MEDICINE AUSTRALASIA, 2008, 20 (01) :1-9
[3]   Simulation in a Disaster Drill: Comparison of High-fidelity Simulators versus Trained Actors [J].
Gillett, Brian ;
Peckler, Brad ;
Sinert, Richard ;
Onkst, Cherie ;
Nabors, Spencer ;
Issley, Steven ;
Maguire, Christopher ;
Galwankarm, Sagar ;
Arquilla, Bonnie .
ACADEMIC EMERGENCY MEDICINE, 2008, 15 (11) :1144-1151
[4]  
Mayer V, 2013, MINERVA ANESTESIOL, V79, P264
[5]   A structured literature review on the use of high fidelity patient simulators for teaching in emergency medicine [J].
McFetrich, J. .
EMERGENCY MEDICINE JOURNAL, 2006, 23 (07) :509-511
[6]   Simulation in resuscitation training [J].
Perkins, Gavin D. .
RESUSCITATION, 2007, 73 (02) :202-211
[7]  
Schulz C, 2011, NOTFALL RETTUNGSMED, V14, P673, DOI 10.1007/s10049-011-1409-0
[8]   A tool for immediate and automated assessment of resuscitation skills for a full-scale simulator [J].
Schulz C.M. ;
Mayer V. ;
Kreuzer M. ;
Kochs E.F. ;
Schneider G. .
BMC Research Notes, 4 (1)
[9]  
SEFRIN P, 2003, DTSCH ARZTEBL, V100, pA2058
[10]   Simulation in Emergency Medicine Training [J].
Ten Eyck, Raymond P. .
PEDIATRIC EMERGENCY CARE, 2011, 27 (04) :333-344