On the investigation of energy saving aspects of commercial lifts

被引:6
作者
Papanikolaou, N. [1 ]
Loupis, M. [2 ]
Spiropoulos, N. [3 ]
Mitronikas, E. [4 ]
Tatakis, E. [4 ]
Christodoulou, C. [1 ]
Zarikas, V. [2 ]
Tsiftsis, T. [2 ]
机构
[1] Democritus Univ Thrace, Elect Machines Lab, V Sofias 12, Xanthi 67100, Greece
[2] TEI Cent Greece, Dept Elect Engn, Lamia Campus, Lamia 35100, Greece
[3] KLEEMANN HELLAS SA, Ind Area Kilkis, R&D Dept, Kilkis 61100, Greece
[4] Univ Patras, Lab Electromech Energy Convers, Patras 26504, Greece
关键词
Energy saving; Elevators; Regenerative braking; SYSTEM; REGENERATION;
D O I
10.1007/s12053-016-9495-y
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper investigates energy efficiency issues in modern lifts, based on the VDI 4707 guidelines, in the context of "KLEEMANN-LESS" research project, funded by national resources and the EU. The above analysis is applied to various lift types manufactured by the Greek multinational company IeLEEMAN HELLAS. The obtained results indicate the relationship between critical technical parameters, such as the elevator driving system type and the standby energy consumption, according to the aforementioned standard. Furthermore, in the current work, new techniques for energy savings are proposed, employing realistic scenarios, which significantly enhance energy efficiency. Experimental work shows that an energy saving of up to 40% can be achieved. The outputs of the current work are not limited to lift models manufactured by KLEEMAN HELLAS, but concern the majority of lift manufacturers as well.
引用
收藏
页码:945 / 956
页数:12
相关论文
共 50 条
[1]   On the investigation of energy saving aspects of commercial lifts [J].
Ν. Papanikolaou ;
M. Loupis ;
Ν. Spiropoulos ;
Ε. Mitronikas ;
Ε. Τatakis ;
C. Christodoulou ;
V. Zarikas ;
T. Τsiftsis .
Energy Efficiency, 2017, 10 :945-956
[2]   A system for energy saving in commercial and organizational buildings [J].
Abdi, H. (hamid.abdi@deakin.edu.au), 2013, Springer Science and Business Media Deutschland GmbH (22) :1083-1091
[3]   Energy saving for fluorescent lighting in commercial buildings [J].
Ahmad, S ;
Lee, SR ;
Dehbonei, H ;
Nayar, C .
Conference Record of the 2005 IEEE Industry Applications Conference, Vols 1-4, 2005, :2965-2971
[4]   Theoretical and experimental aspects of saving energy in fans [J].
Dizadji, N. ;
Mahmoudkhani, A. M. ;
Nouri, N. .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2012, 9 (04) :729-736
[5]   Theoretical and experimental aspects of saving energy in fans [J].
N. Dizadji ;
A. M. Mahmoudkhani ;
N. Nouri .
International Journal of Environmental Science and Technology, 2012, 9 :729-736
[6]   An investigation on the energy-saving effect of a hybrid electric-power steering system for commercial vehicles [J].
Park, Ji In ;
Jeon, Kawngki ;
Yi, Kyongsu .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2019, 233 (06) :1623-1648
[7]   Aspects of Energy Saving of Oil-Producing Enterprises [J].
Midor, Katarzyna ;
Ivanova, Tatyana N. ;
Molenda, Michal ;
Bialy, Witold ;
Zakharov, Oleg V. .
ENERGIES, 2022, 15 (01)
[8]   Analysis of energy saving potential in commercial buildings of Hong Kong [J].
Yang Jia ;
Chan Kwok-tai ;
Wu Xiang-sheng ;
Yang Xiao-feng .
JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2006, 13 :60-64
[9]   A Cost Effective Energy Saving of Fluorescent Lighting in Commercial Buildings [J].
Lee, Seong-Ryong ;
Nayar, Chemmangot V. .
JOURNAL OF POWER ELECTRONICS, 2012, 12 (01) :215-222
[10]   Investigation and implementation of environmental protection and energy saving [J].
Du, Yi ;
Chen, Qingxin ;
Chen, Jianwei .
RENEWABLE AND SUSTAINABLE ENERGY, PTS 1-7, 2012, 347-353 :3271-+