NIKA: A millimeter-wave kinetic inductance camera

被引:107
作者
Monfardini, A. [1 ,2 ]
Swenson, L. J. [1 ,2 ]
Bideaud, A. [1 ,2 ]
Desert, F. X. [6 ]
Yates, S. J. C. [4 ]
Benoit, A. [1 ,2 ]
Baryshev, A. M. [3 ]
Baselmans, J. J. A. [4 ]
Doyle, S. [7 ]
Klein, B. [8 ]
Roesch, M. [9 ]
Tucker, C. [7 ]
Ade, P. [7 ]
Calvo, M.
Camus, P. [1 ,2 ]
Giordano, C. [5 ]
Guesten, R. [8 ]
Hoffmann, C. [1 ,2 ]
Leclercq, S. [9 ]
Mauskopf, P. [7 ]
Schuster, K. F. [9 ]
机构
[1] CNRS, Inst Neel, F-38042 Grenoble, France
[2] Univ Grenoble 1, F-38042 Grenoble, France
[3] Univ Groningen, SRON Netherlands Inst Space Res, NL-9700 AV Groningen, Netherlands
[4] Univ Groningen, Netherlands Inst Space Res SRON, NL-3584 CA Utrecht, Netherlands
[5] Univ Roma La Sapienza, Dipartimento Fis, I-00185 Rome, Italy
[6] Observ Grenoble, Astrophys Lab, F-38041 Grenoble, France
[7] Cardiff Univ, Cardiff Sch Phys & Astron, Cardiff CF24 3AA, S Glam, Wales
[8] Max Planck Inst Radioastron, D-53121 Bonn, Germany
[9] Inst RadioAstron Millimetr, F-38406 St Martin Dheres, France
关键词
instrumentation: detectors; submillimeter: general; LARGE ARRAYS; MULTIPLEXER; RESONATORS; BOLOMETER;
D O I
10.1051/0004-6361/201014727
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Context. Current generation millimeter wavelength detectors suffer from scaling limits imposed by complex cryogenic readout electronics. These instruments typically employ multiplexing ratios well below a hundred. To achieve multiplexing ratios greater than a thousand, it is imperative to investigate technologies that intrinsically incorporate strong multiplexing. One possible solution is the kinetic inductance detector (KID). To assess the potential of this nascent technology, a prototype instrument optimized for the 2 mm atmospheric window was constructed. Known as the Neel IRAM KID Array (NIKA), it has recently been tested at the Institute for Millimetric Radio Astronomy (IRAM) 30-m telescope at Pico Veleta, Spain. Aims. There were four principle research objectives: to determine the practicality of developing a giant array instrument based on KIDs, to measure current in-situ pixel sensitivities, to identify limiting noise sources, and to image both calibration and scientifically-relevant astronomical sources. Methods. The detectors consisted of arrays of high-quality superconducting resonators electromagnetically coupled to a transmission line and operated at similar to 100 mK. The impedance of the resonators was modulated by incident radiation; two separate arrays were tested to evaluate the efficiency of two unique optical-coupling strategies. The first array consisted of lumped element kinetic inductance detectors (LEKIDs), which have a fully planar design properly shaped to enable direct absorbtion. The second array consisted of antenna-coupled KIDs with individual sapphire microlenses aligned with planar slot antennas. Both detectors utilized a single transmission line along with suitable room-temperature digital electronics for continuous readout. Results. NIKA was successfully tested in October 2009, performing in line with expectations. The measurement resulted in the imaging of a number of sources, including planets, quasars, and galaxies. The images for Mars, radio star MWC349, quasar 3C345, and galaxy M87 are presented. From these results, the optical NEP was calculated to be around 1x10(-15) W/Hz(1/2). A factor of 10 improvement is expected to be readily feasible by improvements in the detector materials and reduction of performance-degrading spurious radiation.
引用
收藏
页数:6
相关论文
共 20 条
  • [1] A time domain multiplexer for large arrays of high impedance low temperature bolometers
    Benoit, A.
    Yates, S. J. C.
    Gremion, E.
    Camus, P.
    Durand, T.
    Hoffmann, C.
    Leclercq, S.
    Monfardini, A.
    Cavanna, A.
    Etienne, B.
    Gennser, U.
    Jin, Y.
    [J]. JOURNAL OF LOW TEMPERATURE PHYSICS, 2008, 151 (3-4) : 940 - 945
  • [2] BENOIT A, 2008, P SOC PHOTO OPT INS, V7020, pNIL82
  • [3] Observation of quantum oscillations between a Josephson phase qubit and a microscopic resonator using fast readout
    Cooper, KB
    Steffen, M
    McDermott, R
    Simmonds, RW
    Oh, S
    Hite, DA
    Pappas, DP
    Martinis, JM
    [J]. PHYSICAL REVIEW LETTERS, 2004, 93 (18) : 180401 - 1
  • [4] A broadband superconducting detector suitable for use in large arrays
    Day, PK
    LeDuc, HG
    Mazin, BA
    Vayonakis, A
    Zmuidzinas, J
    [J]. NATURE, 2003, 425 (6960) : 817 - 821
  • [5] Optimisation of Lumped Element Kinetic Inductance Detectors for use in ground based mm and sub-mm arrays
    Doyle, Simon
    Mauskopf, Philip
    Zhang, Jin
    Withington, Stafford
    Goldie, David
    Glowacka, Dorota
    Monfardini, Alessandro
    Swenson, Loren
    Roesch, Markus
    [J]. LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 : 156 - +
  • [6] Noise properties of superconducting coplanar waveguide microwave resonators
    Gao, Jiansong
    Zmuidzinas, Jonas
    Mazin, Benjamin A.
    LeDuc, Henry G.
    Day, Peter K.
    [J]. APPLIED PHYSICS LETTERS, 2007, 90 (10)
  • [7] Experimental evidence for a surface distribution of two-level systems in superconducting lithographed microwave resonators
    Gao, Jiansong
    Daal, Miguel
    Vayonakis, Anastasios
    Kumar, Shwetank
    Zmuidzinas, Jonas
    Sadoulet, Bernard
    Mazin, Benjamin A.
    Day, Peter K.
    Leduc, Henry G.
    [J]. APPLIED PHYSICS LETTERS, 2008, 92 (15)
  • [8] A fully lithographed voltage-biased superconducting spiderweb bolometer
    Gildemeister, JM
    Lee, AT
    Richards, PL
    [J]. APPLIED PHYSICS LETTERS, 1999, 74 (06) : 868 - 870
  • [9] NONLINEAR MICROWAVE PROPERTIES OF SUPERCONDUCTING NB MICROSTRIP RESONATORS
    GOLOSOVSKY, MA
    SNORTLAND, HJ
    BEASLEY, MR
    [J]. PHYSICAL REVIEW B, 1995, 51 (10): : 6462 - 6469
  • [10] Synthesizing arbitrary quantum states in a superconducting resonator
    Hofheinz, Max
    Wang, H.
    Ansmann, M.
    Bialczak, Radoslaw C.
    Lucero, Erik
    Neeley, M.
    O'Connell, A. D.
    Sank, D.
    Wenner, J.
    Martinis, John M.
    Cleland, A. N.
    [J]. NATURE, 2009, 459 (7246) : 546 - 549