Structural health continuous monitoring of buildings - A modal parameters identification system

被引:0
作者
Muttillo, Mirco [1 ]
Di Battista, Luca [2 ]
de Rubeis, Tullio [1 ]
Nardi, Iole [3 ]
机构
[1] Univ Aquila, Dept Ind & Informat Engn & Econ DIIIE, Laquila, Italy
[2] Univ Aquila, Dept Informat Engn Comp Sci & Math DISIM, Laquila, Italy
[3] ENEA Casaccia Res Ctr, Energy Efficiency Unit, Dept DUEE, Santa Maria Di Galeria, Italy
来源
2019 4TH INTERNATIONAL CONFERENCE ON SMART AND SUSTAINABLE TECHNOLOGIES (SPLITECH) | 2019年
关键词
Structural health monitoring (SHM); modal parameters; stochastic subspace identification (SSI); data acquisition system; health diagnosis; DAMAGE DETECTION; VIBRATION;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Monitoring systems play a key role in maintaining the buildings' structural health. Although in the last decades the structural monitoring has experienced a considerable growth, the monitoring systems still require remarkable installation efforts and significant costs. Due to these disadvantages, the spread of such systems was scarce, and the duration of experimental phases was often short. The aim of this work is the design of a Structural Health Monitoring (SHM) system to continuously monitor and check the structural behavior throughout the buildings' lifespan. The system, made up of a customized datalogger and slave devices, allows the continuous monitoring of structures' acceleration thanks to its ease of installation and low cost. The proposed system is mainly based on a microcontroller that: i) communicates with the nodes via RS485 bus, ii) synchronizes the acquisition samples, iii) acquires the data measured by the nodes. The system was tested on a cantilever aluminum structure, through three different experimental campaigns and the measured data, collected in an internal memory of the datalogger, were post-processed via Matlab algorithm. The results allowed to evaluate the modal parameters (frequencies, damping and modal shapes) of the analyzed structure and its health.
引用
收藏
页码:135 / 138
页数:4
相关论文
共 21 条
[1]   Effects of testing, analysis, damage, and environment on modal parameters [J].
Alampalli, S .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2000, 14 (01) :63-74
[2]  
Brincker R., 2006, P 24 IMAC ST LOUIS M, P279
[3]   Vibration of a cracked cantilever beam [J].
Chondros, TG ;
Dimarogonas, AD .
JOURNAL OF VIBRATION AND ACOUSTICS-TRANSACTIONS OF THE ASME, 1998, 120 (03) :742-746
[4]   Long-term monitoring and data analysis of the Tamar Bridge [J].
Cross, E. J. ;
Koo, K. Y. ;
Brownjohn, J. M. W. ;
Worden, K. .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2013, 35 (1-2) :16-34
[5]   A first approach to universal daylight and occupancy control system for any lamps: Simulated case in an academic classroom [J].
de Rubeis, Tullio ;
Muttillo, Mirco ;
Pantoli, Leonardo ;
Nardi, Iole ;
Leone, Ivan ;
Stornelli, Vincenzo ;
Ambrosini, Dario .
ENERGY AND BUILDINGS, 2017, 152 :24-39
[6]   On robust regression analysis as a means of exploring environmental and operational conditions for SHM data [J].
Dervilis, N. ;
Worden, K. ;
Cross, E. J. .
JOURNAL OF SOUND AND VIBRATION, 2015, 347 :279-296
[7]   Dual band harvester architecture for autonomous remote sensors [J].
Di Marco, P. ;
Stornelli, V. ;
Ferri, G. ;
Pantoli, L. ;
Leoni, A. .
SENSORS AND ACTUATORS A-PHYSICAL, 2016, 247 :598-603
[8]   Subspace-based damage detection under changes in the ambient excitation statistics [J].
Doehler, Michael ;
Mevel, Laurent ;
Hille, Falk .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2014, 45 (01) :207-224
[9]   Crack detection by modal analysis in 3D beams based on FEM [J].
El-Kafrawy, Aly .
INTERNATIONAL JOURNAL OF MECHANICS AND MATERIALS IN DESIGN, 2011, 7 (04) :265-282
[10]  
Gabriele T, 2015, 2015 18TH AISEM ANNUAL CONFERENCE