Reference values of respiratory impedance with impulse oscillometry in healthy Chinese adults

被引:16
|
作者
Liang, Xiao-Lin [1 ]
Gao, Yi [1 ]
Guan, Wei-Jie [1 ]
Du, Jing [2 ]
Chen, Li [3 ]
Han, Wen [4 ]
Liu, Jin-Ming [5 ]
Lu, Yong [6 ,7 ]
Peng, Yi [8 ]
Zhao, Bing-Rong [9 ]
Wang, Tao [10 ]
Zheng, Jin-Ping [1 ]
机构
[1] Guangzhou Med Univ, Guangzhou Inst Resp Hlth, State Key Lab Resp Dis, Affiliated Hosp 1,Natl Clin Res Ctr Resp Dis, Guangzhou, Peoples R China
[2] Sichuan Univ, West China Hosp, Dept Resp & Crit Care, Chengdu, Peoples R China
[3] Fujian Med Univ, Affiliated Hosp 1, Dept Resp Med, Fuzhou, Peoples R China
[4] Shanxi Med Univ, Hosp 3, Shanxi Bethune Hosp,Shanxi Acad Med Sci, Dept Resp & Crit Care Med,Tongji Shanxi Hosp, Taiyuan, Peoples R China
[5] Tongji Univ, Sch Med, Shanghai Pulm Hosp, Dept Pulm Funct Test, Shanghai, Peoples R China
[6] Capital Med Univ, Dept Resp & Crit Care Med, Beijing Inst Resp Med, Beijing, Peoples R China
[7] Capital Med Univ, Beijing Chao Yang Hosp, Beijing, Peoples R China
[8] Huazhong Univ Sci & Technol, Union Hosp Tongji Med Coll, Dept Resp Med, Wuhan, Peoples R China
[9] Cent South Univ, Xiangya Hosp, Branch Natl Clin Res Ctr Resp Dis, Natl Key Clin Specialty,Dept Resp Med, Changsha, Peoples R China
[10] Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Resp & Crit Care Med, Wuhan, Peoples R China
关键词
Reference values; respiratory impedance; impulse oscillometry (IO); forced oscillation technique (FOT); adult; PREDICTIVE EQUATIONS; PULMONARY-FUNCTION; ASTHMA CONTROL; CHILDREN; SYSTEM; RECOMMENDATIONS;
D O I
10.21037/jtd-20-3376
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Impulse oscillometry (IO) is a non-invasive pulmonary function test for measuring respiratory impedance. Available reference equations of IO indices for adults are limited. The aim of this study was to develop reference equations of IO indices for Chinese adults. Methods: In a multicentral, cross-sessional study of IO in Chinese adults, IO data from healthy subjects were collected from 19 general hospitals across China between 2016 and 2018. Oscillometry measurements were conducted in accordance with recommendations of the European Respiratory Society (ERS). Multiple linear regression was performed to develop sex-specific reference equations of IO indices. Results: IO measurements were performed in 1,318 subjects, of which 567 subjects were defined as healthy individuals with acceptable IO data and were included in the final analysis. Reference equations and limits of normal [lower limit of normal (LLN)/upper limit of normal (ULN)] of IO indices were developed separately for males and females. Height but not age was shown to be the most influential contributor to IO indices. The reference equations currently used in lung function laboratories predicted higher R5 and X5. Normal ranges of R5 and X5 recommended by the equipment manufacturer were clearly different from the ULN/ LLN derived from the reference equations. Conclusions: Reference equations of IO indices for Chinese adults from a wide region were provided in this study. It is necessary to update new IO reference equations and adopt ULN/LLN as normal ranges of IO indices. Trial Registration: This study was registered at www.clinicaltrials.gov as part of a larger study NCT03467880.
引用
收藏
页码:3680 / +
页数:20
相关论文
共 50 条
  • [1] Reference values of impulse oscillometry (IOS) for healthy Indian adults
    Moitra, Subhabrata
    Moitra, Saibal
    Ghosh, A. K.
    Sengupta, S.
    Das, P. K.
    Das, A.
    Mitra, R.
    Murgia, N.
    Usmani, O. S.
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2020, 24 (05) : 536 - 539
  • [2] Reference equations of the impulse oscillatory in healthy Thai adults
    Deesomchok, Athavudh
    Chaiwong, Warawut
    Liwsrisakun, Chalerm
    Namwongprom, Sirianong
    Pothirat, Chaicharn
    JOURNAL OF THORACIC DISEASE, 2022, 14 (05) : 1384 - +
  • [3] Reference values for respiratory system impedance by using impulse oscillometry in children aged 2-11 years
    Dencker, M
    Malmberg, LP
    Valind, S
    Thorsson, O
    Karlsson, MK
    Pelkonen, A
    Pohjanpalo, A
    Haahtela, T
    Turpeinen, M
    Wollmer, P
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2006, 26 (04) : 247 - 250
  • [4] Values of Impulse Oscillometry in Healthy Mexican Children and Adolescents
    Gochicoa-Rangel, Laura
    Torre-Bouscoulet, Luis
    Martinez-Briseno, David
    Rodriguez-Moreno, Luis
    Cantu-Gonzalez, Gabriela
    Vargas, Mario H.
    RESPIRATORY CARE, 2015, 60 (01) : 119 - 127
  • [5] Reference values of impulse oscillometry (IOS) for healthy Chinese children aged 4-17 years
    Wu, Jinhong
    Zhang, Hao
    Shi, Yongsheng
    Wang, Jinrong
    Han, Yuling
    Zhang, Qiaoling
    Wang, Ning
    Liu, Sha
    Zhang, Yuehua
    Zi, Huifen
    Wang, Fei
    Liu, Aihong
    Song, Yuxin
    Jia, ChunMei
    Feng, Yong
    Liu, Quanhua
    Wan, Liya
    Ji, Minghong
    Long, Zhen
    Huang, Jianfeng
    Liu, Li
    Sun, Yun
    Tang, Suping
    Dong, Xiaoyan
    Zhou, Xiaojian
    Jiang, Wenhui
    Shen, Li
    Jiang, Haohua
    RESPIRATORY RESEARCH, 2022, 23 (01)
  • [6] Reference Equations for Impulse Oscillometry System Parameters in Healthy Brazilian Children and Adolescents
    de Assumpcao, Maira S.
    Goncalves, Renata M.
    Martins, Renata
    Bobbio, Tatiana G.
    Schivinski, Camila I. S.
    RESPIRATORY CARE, 2016, 61 (08) : 1090 - 1099
  • [7] Validating Reference Equations for Impulse Oscillometry in Healthy Mexican Children
    Gochicoa-Rangel, Laura
    del Rio-Hidalgo, Rodrigo
    Hernandez-Ruiz, Juana
    Rodriguez-Moreno, Luis
    Martinez-Briseno, David
    Mora-Romero, Uri
    Cid-Juarez, Silvia
    Garcia-Sancho, Cecilia
    Torre-Bouscoulet, Luis
    RESPIRATORY CARE, 2017, 62 (09) : 1156 - 1165
  • [8] Impulse oscillometry reference values and bronchodilator response in three- to five-year old children living at high altitude
    Duenas-Meza, Elida
    Correa, Eliana
    Lopez, Eliana
    Carlos Morales, Juan
    Eduardo Aguirre-Franco, Carlos
    Fabian Morantes-Ariza, Carlos
    Eduardo Granados, Carlos
    Gonzalez-Garcia, Mauricio
    JOURNAL OF ASTHMA AND ALLERGY, 2019, 12 : 263 - 271
  • [9] Impulse oscillometry - Reference values in children 100 to 150 cm in height and 3 to 10 years of age
    Frei, J
    Jutla, J
    Kramer, G
    Hatzakis, GE
    Ducharme, FM
    Davis, GM
    CHEST, 2005, 128 (03) : 1266 - 1273
  • [10] Forty years of reference values for respiratory system impedance in adults: 1977-2017
    Kalchiem-Dekel, Or
    Hines, Stella E.
    RESPIRATORY MEDICINE, 2018, 136 : 37 - 47