Troubleshooting Implanted Cardioverter Defibrillator Sensing Problems I

被引:54
作者
Swerdlow, Charles D. [1 ]
Asirvatham, Samuel J. [2 ]
Ellenbogen, Kenneth A. [3 ]
Friedman, Paul A. [2 ]
机构
[1] Cedars Sinai Med Ctr, Cedars Sinai Heart Inst, Los Angeles, CA 90048 USA
[2] Mayo Clin, Div Cardiol, Rochester, MN USA
[3] Virginia Commonwealth Univ, Sch Med, Div Cardiol, Richmond, VA USA
关键词
sensing; shock; INAPPROPRIATE ICD DISCHARGE; VENTRICULAR-TACHYCARDIA; LEAD FAILURE; ELECTROMAGNETIC-INTERFERENCE; DEVICE INTERACTIONS; ASSIST DEVICES; QT SYNDROME; RARE CAUSE; FOLLOW-UP; SHOCKS;
D O I
10.1161/CIRCEP.114.002344
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
[No abstract available]
引用
收藏
页码:1237 / 1261
页数:25
相关论文
共 116 条
  • [1] Independent multicenter study of Riata and Riata ST implantable cardioverter-defibrillator leads
    Abdelhadi, Raed H.
    Saba, Samir F.
    Ellis, Christopher R.
    Mason, Pamela K.
    Kramer, Daniel B.
    Friedman, Paul A.
    Gura, Melanie T.
    DiMarco, John P.
    Mugglin, Andrew S.
    Reynolds, Matthew R.
    Bazaz, Raveen R.
    Retel, Linda Kat Linen
    Hayes, David L.
    Hauser, Robert G.
    [J]. HEART RHYTHM, 2013, 10 (03) : 361 - 365
  • [2] Inappropriate ICD discharge due to T-wave oversensing in a patient with the Brugada syndrome
    Alizadeh, A
    Haghjoo, M
    Arya, A
    Fazelifar, AF
    Alasti, M
    Bagherzadeh, AA
    Sadr-Ameli, MA
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 15 (01) : 65 - 68
  • [3] Apfelbaum J, 2011, ANESTHESIOLOGY, V114, P247
  • [4] Ventricular Oversensing after Replacement of an Implantable Cardioverter-Defibrillator
    Arias, Miguel A.
    Puchol, Alberto
    Castellanos, Eduardo
    Pachon, Marta
    Rodriguez-Padial, Luis
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (07): : 925 - 927
  • [5] Assadian Rad Mohammad, 2012, J Tehran Heart Cent, V7, P30
  • [6] Barakpour Hamid, 2009, Indian Pacing Electrophysiol J, V9, P71
  • [7] Simple Method to Eliminate Interference between Ventricular Assist Devices and Cardiac Rhythm Devices
    Baran, David A.
    Martin, Tony
    Blicharz, Donna
    Carr, Candace
    Zucker, Mark J.
    McBride, Lawrence
    Camacho, Margarita
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (09): : 1142 - 1145
  • [8] Effects of External Electrical and Magnetic Fields on Pacemakers and Defibrillators From Engineering Principles to Clinical Practice
    Beinart, Roy
    Nazarian, Saman
    [J]. CIRCULATION, 2013, 128 (25) : 2799 - 2809
  • [9] Clinical Predictors of Fidelis Lead Failure Report From the Canadian Heart Rhythm Society Device Committee
    Birnie, David H.
    Parkash, Ratika
    Exner, Derek V.
    Essebag, Vidal
    Healey, Jeffrey S.
    Verma, Atul
    Coutu, Benoit
    Kus, Teresa
    Mangat, Iqwal
    Ayala-Paredes, Felix
    Nery, Pablo
    Wells, George
    Krahn, Andrew D.
    [J]. CIRCULATION, 2012, 125 (10) : 1217 - 1225
  • [10] Overcoming Electromagnetic Interference by LVADs on ICD Function by Shielding the ICD Programmer Wand and Extension Cable
    Biviano, Angelo
    Mancini, Donna
    Naka, Yoshifumi
    Arellano, Jerry
    Garan, Hasan
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (07): : 945 - 948