Seismic behaviour of concrete-filled steel tubular columns with internal H-section steel under pure torsion and compression-torsion loads

被引:8
|
作者
Pi, Zheng-Bo [1 ]
Su, Meni [2 ]
Peng, Yuan-Yuan [3 ]
Wang, Yu-Hang [1 ,4 ]
Luo, Wei [5 ]
Lan, Yong-Sen [5 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing, Peoples R China
[2] Univ Manchester, Sch Mech Aerosp & Civil Engn, Manchester, Lancs, England
[3] Chongqing Univ, Dept Capital Construct & Planning, Chongqing, Peoples R China
[4] Chongqing Univ, Key Lab New Technol Construct Cities Mt Area, Minist Educ, Chongqing, Peoples R China
[5] CSIC HaiZhuang Wind Power Co Ltd, Chongqing, Peoples R China
关键词
Compressive torsional capacity; Concrete-filled steel tube columns; Energy dissipation capacity; Torsional behaviour; Torsional stiffness degradation; Shear capacity of steel; TUBE COLUMNS; TESTS;
D O I
10.1016/j.engstruct.2020.110761
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled steel tube (CFST) columns have been widely used in the construction industry because of their excellent compression capacity and torsion resistance. Regarding traditional CFST columns, the H-CFST column with an additional H-section steel member embedded in the core concrete provides improved fire and compression resistance. In this study, the seismic performance of nine H-CFST columns under cyclic torsional and compression-cyclic torsional loads was experimentally analysed. In the experiments, the failure mode, torque versus torsional angle hysteresis, torque versus torsional angle skeleton, torsional stiffness degradation, and energy dissipation capacity were determined. The hysteretic curves of the H-CFST columns under torsion were relatively plump in shape and exhibited no 'pinching' phenomenon, and the torsional stiffness of the H-CFST columns under unloading and reverse loading was approximately equal to the initial torsional stiffness. In addition, the applied compression had remarkable effects on the torsional capacity, torsional ductility, torsional stiffness, and hysteretic loop energy dissipation of the H-CFST columns. The shear capacities of the steel and concrete under normal stress or combined normal and shear stress were determined based on the latest theories and test results. Moreover, design method for the determination of the torsional capacity of H-CFST columns under compressive torsion is proposed based on the test results, and the theoretical contribution ratio of the H-section steel, steel tube, and concrete in the H-CFST columns to the torsional capacity was determined.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Study on seismic behavior of concrete filled steel tube columns under pure torsion and compression-torsion combined action
    Nie, Jianguo
    Wang, Yuhang
    Fan, Jiansheng
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2014, 47 (01): : 47 - 58
  • [2] Behavior of circular concrete-filled steel tubular columns under pure torsion
    Ding, Fa-xing
    Fu, Qiang
    Wen, Bing
    Zhou, Qi-shi
    Liu, Xue-mei
    STEEL AND COMPOSITE STRUCTURES, 2018, 26 (04): : 501 - 511
  • [3] Experimental study on seismic behavior of concrete filled steel tube columns under pure torsion and compression-torsion cyclic load
    Nie Jian-guo
    Wang Yu-hang
    Fan Jian-sheng
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 79 : 115 - 126
  • [4] Pseudo-static experimental study on concrete-filled steel tubular columns with internal H-section steel subjected to cyclic torsion-bending loads
    Yuan, Shuai
    Pi, Zhengbo
    Wang, Yuhang
    Journal of Railway Science and Engineering, 2024, 21 (09) : 3706 - 3718
  • [5] Size effect simulations on compression-torsion failure of concrete-filled steel tube columns
    Jin L.
    Wang Z.
    Li D.
    Lei Y.
    Zhu H.
    Du X.
    Zhongguo Kexue Jishu Kexue/Scientia Sinica Technologica, 2024, 54 (04): : 747 - 760
  • [6] Torsional behaviour of concrete-filled circular steel tubular members under coupled compression and torsion
    Jia, Zhi-Lu
    Shi, Yan-Li
    Xian, Wei
    Wang, Wen-Da
    STRUCTURES, 2021, 34 : 931 - 946
  • [7] Mechanical behaviors of concrete-filled rectangular steel tubular under pure torsion
    Ding, Fa-xing
    Sheng, Shi-jing
    Yu, Yu-jie
    Yu, Zhi-wu
    STEEL AND COMPOSITE STRUCTURES, 2019, 31 (03): : 291 - 301
  • [8] Experimental study on Tapered Concrete-Filled Double Skin Steel Tubular columns under torsion
    Deng, Ran
    Zhou, Xu-Hong
    Wang, Yu-Hang
    Bai, Jiu-Lin
    Deng, Xiao-Wei
    THIN-WALLED STRUCTURES, 2022, 177
  • [10] Investigation on special-shaped concrete-filled steel tubular column under pure torsion
    Han, Xinchen
    Yang, Yuanlong
    Zhou, Qipeng
    Chen, Yohchia Frank
    Xu, Wenbin
    ENGINEERING STRUCTURES, 2024, 313