Characterization of Yb-doped silica optical fiber as real-time dosimeter

被引:0
作者
Veronese, Ivan [1 ,2 ]
Chiodini, Norberto [3 ]
Cialdi, Simone [1 ,2 ]
D'Ippolito, Eduardo [1 ]
Fasoli, Mauro [3 ]
Gallo, Salvatore [1 ,2 ]
Mones, Eleonora [4 ]
Vedda, Anna [3 ]
Loi, Gianfranco [4 ]
机构
[1] Univ Milan, Dept Phys, Milan, Italy
[2] Natl Inst Nucl Phys INFN, Sect Milan, Milan, Italy
[3] Univ Milano Bicocca, Dipartimento Sci Mat, Milan, Italy
[4] Azienda Osped Maggiore Carita, Med Phys Dept, Novara, Italy
来源
HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XIX | 2017年 / 10392卷
关键词
Ytterbium; optical fiber; radioluminescence; Cerenkov; dosimetry; doped silica; radiotherapy; CERENKOV RADIATION; ELECTRON-BEAMS; FAILURE MODE; RADIOTHERAPY; SCINTILLATOR; SYSTEM; IONS;
D O I
10.1117/12.2272573
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The near-infrared radioluminescence and dosimetric properties of Yb-doped silica optical fibers, coupled with an optical detector prototype based on an avalanche photo-diode, were studied by irradiating the fibers with clinical beams generated by a Varian Trilogy accelerator. The performances of the system in standard and small field sizes have been also investigated comparing the output factor, percent depth dose and off axis ratio measurements of the prototypal dosimetric system with other commercial sensors. The results demonstrated that the drawback due to the stem effect in Yb-doped silica optical fibers can be managed in a simple but effective way by optical filtering. These features, together with the accuracy and precision achieved by Yb-doped fibers in relative dose assessments make the device promising for in-vivo dosimetry studies in radiation therapy.
引用
收藏
页数:7
相关论文
共 34 条
[1]  
Beddar A. S., 2007, RADIAT MEAS, V41, pS124, DOI DOI 10.1016/J.RADMEAS.2007.01.002
[2]   CERENKOV LIGHT GENERATED IN OPTICAL FIBERS AND OTHER LIGHT PIPES IRRADIATED BY ELECTRON-BEAMS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (04) :925-935
[3]  
Beddar Sam., 2016, Scintillation dosimetry, DOI DOI 10.1201/9781315372655
[4]  
Begnozzi L, 2014, RADIOPROTECTION, V49, P43, DOI [10.1051/radiopro/2013079, 10.1051/radiopro/20013079]
[5]   Dosimetric characterization of the Exradin W1 plastic scintillator detector through comparison with an in-house developed scintillator system [J].
Beierholm, A. R. ;
Behrens, C. F. ;
Andersen, C. E. .
RADIATION MEASUREMENTS, 2014, 69 :50-56
[6]   Characterization of the Exradin W1 scintillator for use in radiotherapy [J].
Carrasco, P. ;
Jornet, N. ;
Jordi, O. ;
Lizondo, M. ;
Latorre-Musoll, A. ;
Eudaldo, T. ;
Ruiz, A. ;
Ribas, M. .
MEDICAL PHYSICS, 2015, 42 (01) :297-304
[7]   A temporal method of avoiding the Cerenkov radiation generated in organic scintillator dosimeters by pulsed mega-voltage electron and photon beams [J].
Clift, MA ;
Johnston, PN ;
Webb, DV .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (08) :1421-1433
[8]   Small Field Dosimetry: What Have We Learnt? [J].
Das, Indra J. ;
Morales, Johnny ;
Francescon, Paolo .
MEDICAL PHYSICS: FOURTEENTH MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2016, 1747
[9]   Monte Carlo simulated corrections for beam commissioning measurements with circular and MLC shaped fields on the CyberKnife M6 System: a study including diode, microchamber, point scintillator, and synthetic microdiamond detectors [J].
Francescon, P. ;
Kilby, W. ;
Noll, J. M. ;
Masi, L. ;
Satariano, N. ;
Russo, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (03) :1076-1095
[10]   Variation of kQclin, Qmsrfclin, fmsr for the small-field dosimetric parameters percentage depth dose, tissue-maximum ratio, and off-axis ratio [J].
Francescon, Paolo ;
Beddar, Sam ;
Satariano, Ninfa ;
Das, Indra J. .
MEDICAL PHYSICS, 2014, 41 (10)