Evaluation of Electrospray Ionization Mass Spectrometry as a Tool for Characterization of Small Soluble Protein Aggregates

被引:28
作者
Wang, Guanbo [1 ]
Johnson, Alex J. [1 ]
Kaltashov, Igor A. [1 ]
机构
[1] Univ Massachusetts Amherst, Dept Chem, Amherst, MA 01003 USA
基金
美国国家科学基金会;
关键词
SIZE-EXCLUSION CHROMATOGRAPHY; CHARGE-STATE DISTRIBUTIONS; HUMAN-PLASMA; ESI MS; ANTITHROMBIN; CONFORMERS; POLYMERS; MODEL;
D O I
10.1021/ac203017x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Protein aggregation continues to attract significant interest in many areas of biology and medicine not only due to its pivotal role in the etiology of conformational diseases (such as Parkinson's and Alzheimer's) but also due to its importance in the biopharmaceutical sector, where aggregation of protein therapeutics exerts a deleterious effect on their efficacy and safety. Despite the tremendous success of electrospray ionization mass spectrometry (ESI MS) in a large number of studies of noncovalent protein interactions, application of this technique to study aggregation processes has been very limited so far, and lower resolution techniques, such as size exclusion chromatography (SEC) and analytical ultracentrifugation, remain the default tools in characterizing small soluble protein aggregates. In this work we used heat-stressed human antithrombin III (AT), a 58 kDa glycoprotein, to compare SEC and ESI MS as a means to probe composition of the complex mixture of soluble oligomeric species generated by heat-induced aggregation. SEC allows several oligomeric species to be observed and collected, followed by their identification with ESI MS. The same oligomeric species can be also directly observed in the ESI MS of the unfractionated sample of the heat-stressed AT. The abundance distribution of these small soluble aggregates in ESI MS and SEC cannot be compared directly, since the ESI signal is linked to the molar concentration of the analyte in solution, whereas the UV absorption detection in SEC reports weight concentration. However, once the appropriate corrections are made, the abundance of the small aggregates derived from ESI MS becomes remarkably close to that calculated based on SEC data, suggesting that ESI MS may be directly applied for semiquantitative characterization of soluble protein aggregates.
引用
收藏
页码:1718 / 1724
页数:7
相关论文
共 50 条
[21]   Characterization of Intact Protein Conjugates and Biopharmaceuticals Using Ion-Exchange Chromatography with Online Detection by Native Electrospray Ionization Mass Spectrometry and Top-Down Tandem Mass Spectrometry [J].
Muneeruddin, Khaja ;
Nazzaro, Mark ;
Kaltashov, Igor A. .
ANALYTICAL CHEMISTRY, 2015, 87 (19) :10138-10145
[22]   On the Use of Electrospray Ionization and Desorption Electrospray Ionization Mass Spectrometry for Bulk and Surface Polymer Analysis [J].
Bonnaire, Nicolas ;
Dannoux, Adeline ;
Pernelle, Christine ;
Amekraz, Badia ;
Moulin, Christophe .
APPLIED SPECTROSCOPY, 2010, 64 (07) :810-818
[23]   Electrospray Ionization Mass Spectrometry Fingerprint of the Byrsonima Species [J].
Pereira, Vinicius V. ;
da Fonseca, Fabiana Aparecida ;
Bento, Cecilia S. O. ;
Oliveira, Patricia M. ;
Rocha, Lilian Lucia ;
Augusti, Rodinei ;
Mendonca Filho, Carlos Victor ;
Silva, Roqueline R. .
REVISTA VIRTUAL DE QUIMICA, 2015, 7 (06) :2539-2548
[24]   The application of electrospray ionization mass spectrometry to homogeneous catalysis [J].
Vikse, Krista L. ;
Ahmadi, Zohrab ;
McIndoe, J. Scott .
COORDINATION CHEMISTRY REVIEWS, 2014, 279 :96-114
[25]   Fragmentation studies of sartans by electrospray ionization mass spectrometry [J].
Peng, M. ;
Li, S. ;
Wu, J. ;
Guo, Y. ;
Cao, S. ;
Zhao, Y. .
JOURNAL OF MASS SPECTROMETRY, 2017, 52 (09) :591-596
[26]   Characterization of linear and cyclic polylactic acids and their solvolysis products by electrospray ionization mass spectrometry [J].
Osaka, Issey ;
Watanabe, Mikio ;
Takama, Masashi ;
Murakami, Masahiro ;
Arakawa, Ryuichi .
JOURNAL OF MASS SPECTROMETRY, 2006, 41 (10) :1369-1377
[27]   Electrospray and matrix-assisted laser desorption/ionization mass spectrometry for the characterization of polyesters [J].
Guittard, J ;
Tessier, M ;
Blais, JC ;
Bolbach, G ;
Rozes, L ;
Marechal, E ;
Tabet, JC .
JOURNAL OF MASS SPECTROMETRY, 1996, 31 (12) :1409-1421
[28]   Characterization of electrospray ionization mass spectrometry for N-diisopropyloxyphosphoryl dipeptide methyl esters [J].
Luo, SZ ;
Li, YM ;
Niu, YL ;
Chen, Y ;
Jiang, YY ;
Chen, J ;
Zhao, YF .
EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2005, 11 (01) :107-117
[29]   Direct observation of basic protein HEWL as an oxoanions receptor by electrospray ionization mass spectrometry [J].
Yang, LF ;
Yu, L ;
Liu, Y ;
Chen, Y ;
Hu, LM ;
Zhao, YF .
LETTERS IN PEPTIDE SCIENCE, 2003, 10 (02) :89-92
[30]   Direct observation of basic protein HEWL as an oxoanions receptor by electrospray ionization mass spectrometry [J].
Lifeng Yang ;
Lin Yu ;
Yan Liu ;
Yong Chen ;
Liming Hu ;
Yufen Zhao .
Letters in Peptide Science, 2003, 10 :89-92