EFFECT OF THERMAL RADIATION ON LOW TEMPERATURE MEASUREMENT FOR VARIOUS TYPES OF TEMPERATURE SENSOR INSTALLATIONS

被引:1
作者
Pavel, Urban [1 ]
Pavel, Hanzelka [1 ]
Tomas, Kralik [1 ]
Ivan, Vlcek [1 ]
Ales, Srnka [1 ]
机构
[1] CAS, Inst Sci Instruments, Vvi, Brno 61264, Czech Republic
来源
14TH CRYOGENICS 2017 IIR INTERNATIONAL CONFERENCE (CRYOGENICS 2017) | 2017年
关键词
Low Temperature; Temperature Sensor; Thermal Radiation; CONDUCTANCE;
D O I
10.18462/iir.cryo.2017.0105
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
We investigated an effect of thermal radiation (300 K) on precision of low temperature measurement of a sample holder (or sample) in an UHV SEM/SPM microscope working at range down to 20 K for various ways of temperature sensor mounting. We designed a special copper casing for installation of Lake Shore temperature sensors (Cernox (TM) and Si diodes) encapsulated in SD packages. The sensor body is attached direct to the casing using indium solder. The current leads pertaining to the sensor are thermally anchored but electrically insulated from the casing. Quality of sensors installation in the casing was tested for various ways of mounting on a cooled plate. Insufficient thermal anchoring of electrical wires and thermal shielding were imitated. Comparative measurement was also performed with sensors in SD package mounted without casing. The experiments proved that our special design of temperature sensors casing is adequate for intended application of temperature measurement of sample holder in UHV SEM/SPM microscope. In contrary, measurement precision of "unprotected" sensors was absolutely unsuitable.
引用
收藏
页码:498 / 501
页数:4
相关论文
共 7 条
[1]  
Ekin JackW., 2011, Experimental Techniques for low temperature measurements: Cryostat Design, Material Properties, and Superconductor Critical-Current Testing p41
[2]   Thermal boundary resistance of mechanical contacts between solids at sub-ambient temperatures [J].
Gmelin, E ;
Asen-Palmer, M ;
Reuther, M ;
Villar, R .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1999, 32 (06) :R19-R43
[3]   Current leads in vacuum space of cryogenic systems [J].
Hanzelka, P .
CRYOGENICS, 1999, 39 (11) :955-961
[4]  
Lake Shore Cryotronics Cryogenic Inc, TEMP SENS PACK MOUNT
[5]  
Lake Shore Cryotronics Inc, SENS PACK INST
[6]   THERMAL CONDUCTANCE OF PRESSED METALLIC CONTACTS AUGMENTED WITH INDIUM FOIL OR APIEZON GREASE AT LIQUID-HELIUM TEMPERATURES [J].
SALERNO, LJ ;
KITTEL, P ;
SPIVAK, AL .
CRYOGENICS, 1994, 34 (08) :649-654
[7]   Thermal conductance measurements of bolted copper joints for SuperCDMS [J].
Schmitt, R. L. ;
Tatkowski, G. ;
Ruschman, M. ;
Golwala, S. ;
Kellaris, N. ;
Daal, M. ;
Hall, J. ;
Hoppe, E. W. .
CRYOGENICS, 2015, 70 :41-46