Toward more intuitive brain-computer interfacing: classification of binary covert intentions using functional near-infrared spectroscopy

被引:48
作者
Hwang, Han-Jeong [1 ]
Choi, Han [2 ]
Kim, Jeong-Youn [2 ]
Chang, Won-Du [2 ]
Kim, Do-Won [2 ,3 ]
Kim, Kiwoong [4 ]
Jo, Sungho [5 ]
Im, Chang-Hwan [2 ]
机构
[1] Kumoh Natl Inst Technol, Dept Med IT Convergence Engn, 61 Daehak Ro, Gumi 730701, Gyeongbuk, South Korea
[2] Hanyang Univ, Dept Biomed Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
[3] Berlin Inst Technol, Machine Learning Grp, Marchstr 23, D-10587 Berlin, Germany
[4] Korea Res Inst Standard & Sci, 267 Gajeong Ro, Daejeon 34113, South Korea
[5] Korea Adv Inst Sci & Technol, Dept Comp Sci, Daejeon 34141, South Korea
基金
新加坡国家研究基金会;
关键词
brain-computer interface; functional near-infrared spectroscopy; binary communication; intuitive paradigm; covert intentions; neurological diseases; SINGLE-TRIAL CLASSIFICATION; MOTOR IMAGERY; COMMUNICATION; CORTEX; LIGHT;
D O I
10.1117/1.JBO.21.9.091303
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In traditional brain-computer interface (BCI) studies, binary communication systems have generally been implemented using two mental tasks arbitrarily assigned to "yes" or "no" intentions (e.g., mental arithmetic calculation for "yes"). A recent pilot study performed with one paralyzed patient showed the possibility of a more intuitive paradigm for binary BCI communications, in which the patient's internal yes/no intentions were directly decoded from functional near-infrared spectroscopy (fNIRS). We investigated whether such an "fNIRS-based direct intention decoding" paradigm can be reliably used for practical BCI communications. Eight healthy subjects participated in this study, and each participant was administered 70 disjunctive questions. Brain hemo-dynamic responses were recorded using a multichannel fNIRS device, while the participants were internally expressing "yes" or "no" intentions to each question. Different feature types, feature numbers, and time window sizes were tested to investigate optimal conditions for classifying the internal binary intentions. About 75% of the answers were correctly classified when the individual best feature set was employed (75.89% +/- 1.39 and 74.08% +/- 2.87 for oxygenated and deoxygenated hemoglobin responses, respectively), which was significantly higher than a random chance level (68.57% for p < 0.001). The kurtosis feature showed the highest mean classification accuracy among all feature types. The grand-averaged hemodynamic responses showed that wide brain regions are associated with the processing of binary implicit intentions. Our experimental results demonstrated that direct decoding of internal binary intention has the potential to be used for implementing more intuitive and user-friendly communication systems for patients with motor disabilities. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Multiclass classification of hemodynamic responses for performance improvement of functional near-infrared spectroscopy-based brain-computer interface
    Shin, Jaeyoung
    Jeong, Jichai
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (06)
  • [12] Classification of Overt and Covert Speech for Near-Infrared Spectroscopy-Based Brain Computer Interface
    Kamavuako, Ernest Nlandu
    Ayub Sheikh, Usman
    Gilani, Syed Omer
    Jamil, Mohsin
    Niazi, Imran Khan
    SENSORS, 2018, 18 (09)
  • [13] Analysis of Different Classification Techniques for Two-Class Functional Near-Infrared Spectroscopy-Based Brain-Computer Interface
    Naseer, Noman
    Qureshi, Nauman Khalid
    Noori, Farzan Majeed
    Hong, Keum-Shik
    COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2016, 2016
  • [14] Evaluation of various mental task combinations for near-infrared spectroscopy-based brain-computer interfaces
    Hwang, Han-Jeong
    Lim, Jeong-Hwan
    Kim, Do-Won
    Im, Chang-Hwan
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (07)
  • [15] Classification of brain hemodynamic signals arising from visual action observation tasks for brain-computer interfaces: A functional near-infrared spectroscopy study
    Abibullaev, Berdakh
    An, Jinung
    Jin, Sang-Hyeon
    Moon, Jeon Il
    MEASUREMENT, 2014, 49 : 320 - 328
  • [16] Temporal hemodynamic classification of two hands tapping using functional near-infrared spectroscopy
    Nguyen Thanh Hai
    Cuong, Ngo Q.
    Khoa, Truong Q. Dang
    Vo Van Toi
    FRONTIERS IN HUMAN NEUROSCIENCE, 2013, 7
  • [17] Vector Phase Analysis Approach for Sleep Stage Classification: A Functional Near-Infrared Spectroscopy-Based Passive Brain-Computer Interface
    Arif, Saad
    Khan, Muhammad Jawad
    Naseer, Noman
    Hong, Keum-Shik
    Sajid, Hasan
    Ayaz, Yasar
    FRONTIERS IN HUMAN NEUROSCIENCE, 2021, 15
  • [18] Online binary decision decoding using functional near-infrared spectroscopy for the development of brain–computer interface
    Noman Naseer
    Melissa Jiyoun Hong
    Keum-Shik Hong
    Experimental Brain Research, 2014, 232 : 555 - 564
  • [19] Physiological noise in near-infrared spectroscopy: Implications for optical brain computer interfacing
    Coyle, S
    Ward, T
    Markham, C
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 4540 - 4543
  • [20] Effectiveness of scalp-hemodynamics reduction to brain-computer interfaces by functional near-infrared spectroscopy
    Sato T.
    Nambu I.
    Wada Y.
    IEEJ Transactions on Electronics, Information and Systems, 2017, 137 (05) : 717 - 723