25-, 23-, and 20-gauge vitrectomy in epiretinal membrane surgery: a comparative study of 553 cases

被引:71
|
作者
Sandali, Otman [1 ]
El Sanharawi, Mohamed [1 ]
Lecuen, Nicolas [1 ]
Barale, Pierre-Olivier [1 ]
Bonnel, Sebastien [1 ]
Basli, Elena [1 ]
Borderie, Vincent [1 ]
Laroche, Laurent [1 ]
Monin, Claire [1 ]
机构
[1] Ctr Hosp Natl Ophtalmol XV XX, F-75571 Paris, France
关键词
20-gauge; 23-gauge; 25-gauge; Vitrectomy; Epiretinal membrane; Visual improvement; Complication; TRANSCONJUNCTIVAL SUTURELESS VITRECTOMY; PARS-PLANA VITRECTOMY; INTRAOCULAR-PRESSURE ELEVATION; POSTOPERATIVE COMPLICATIONS; CORNEAL TOPOGRAPHY; 23-GAUGE; 25-GAUGE; ENDOPHTHALMITIS; SYSTEM; OUTCOMES;
D O I
10.1007/s00417-011-1752-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare the safety and functional outcomes of 25-gauge and 23-gauge (G) micro-incision vitrectomy surgery (MIVS) instrumentation with the standard 20-G vitrectomy system in the treatment of epiretinal membranes (ERM). A retrospective comparative study of 553 consecutive cases with epiretinal membrane who underwent pars plana vitrectomy. Twenty-gauge, 25-gauge and 23-gauge vitrectomy was performed respectively in 347, 91, and 115 eyes. Surgery duration, visual acuity improvement, intraocular pressure variation, intraoperative and postoperative complications were analyzed. The mean surgical time in the 23-G group and in the 25-G group was shorter than in the 20-G group (P < 0.001). Visual improvement was higher 8 days postoperatively in the 25-G group than in the 20-G and 23-G groups (P = 0.035), but not at 6 weeks postoperatively (P = 0.186). In the 20-G group, the IOP increased significantly on the first day postoperatively (P < 0.001), while in the 23-G group, the IOP decreased on the first day postoperatively (P = 0.073). In the 25-G group, the IOP did not change significantly (P = 0.807). The incidence of complications was not statistically significant between the three groups. Retinal breaks were significantly related to the induction of posterior vitreous detachment, independent of the system gauge. In ERM surgery, 23-G and 25-G (MIVS) systems are as safe and effective as the 20-G system, and significantly reduce surgical time. Although the 25-G system provides an earlier visual improvement, the 23- and 25- gauge systems are comparable, and the selection will depend on the surgeon's preference.
引用
收藏
页码:1811 / 1819
页数:9
相关论文
共 50 条
  • [21] 27-gauge and 25-gauge vitrectomy day surgery for idiopathic epiretinal membrane
    Naruse, Saigen
    Shimada, Hiroyuki
    Mori, Ryusaburo
    BMC OPHTHALMOLOGY, 2017, 17
  • [22] SURGICALLY-INDUCED INFLAMMATION WITH 20-, 23-, AND 25-GAUGE VITRECTOMY SYSTEMS
    Inoue, Yuji
    Kadonosono, Kazuaki
    Yamakawa, Tadashi
    Uchio, Eiichi
    Watanabe, Yoichiro
    Yanagi, Yasuo
    Tamaki, Yasuhiro
    Araie, Makoto
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (04): : 477 - 480
  • [23] Mechanical Property Comparison of 23-, 25-, and 27-Gauge Vitrectors across Vitrectomy Systems
    Lai, James M.
    Patel, Veshesh
    Watane, Arjun
    Fils, Aaron J.
    Pakravan, Parastou
    Huang, Chun-Yuh
    Patel, Nimesh
    Sridhar, Jayanth
    Yannuzzi, Nicolas A.
    OPHTHALMOLOGY RETINA, 2022, 6 (11): : 1001 - 1008
  • [24] TRANSCONJUNCTIVAL NONVITRECTOMIZING VITREOUS SURGERY VERSUS 25-GAUGE VITRECTOMY IN PATIENTS WITH EPIRETINAL MEMBRANE A Prospective Randomized Study
    Reibaldi, Michele
    Longo, Antonio
    Avitabile, Teresio
    Bonfiglio, Vincenza
    Toro, Mario D.
    Russo, Andrea
    Viti, Francesca
    Nicolai, Michele
    Saitta, Andrea
    Giovannini, Alfonso
    Mariotti, Cesare
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2015, 35 (05): : 873 - 879
  • [25] Incidence of endophthalmitis after 20-gauge vs 23-gauge vs 25-gauge pars plana vitrectomy
    Ingrid U. Scott
    Harry W. Flynn
    Nur Acar
    Sundeep Dev
    Saad Shaikh
    Robert A. Mittra
    J. Fernando Arevalo
    Andres Kychenthal
    Allen Kunselman
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 377 - 380
  • [26] VITREOUS INCARCERATION IN SCLEROTOMIES AFTER VALVED 23-, 25-, OR 27-GAUGE AND NONVALVED 23-OR 25-GAUGE MACULAR SURGERY
    Tosi, Gian Marco
    Malandrini, Alex
    Cevenini, Gabriele
    Neri, Giovanni
    Marigliani, Davide
    Cerruto, Arianna
    Virgili, Gianni
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (10): : 1948 - 1955
  • [27] Comparative outcomes of pars plana vitrectomy in acute postoperative endophthalmitis with 25-gauge and 20-gauge techniques
    Altan, Tugrul
    Kapran, Ziya
    Eser, Ilker
    Acar, Nur
    Uenver, Yaprak Banu
    Yurttaser, Serap
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2009, 53 (05) : 506 - 511
  • [28] 23-gauge versus 20-gauge vitrectomy: analysis of 110 consecutive cases undergoing epiretinal membrane peeling and macular hole repair23-Gauge versus 20-Gauge Pars-Plana-Vitrektomie: Analyse von 110 Fällen mit epiretinaler Gliose und durchgreifendem Makulaforamen
    Martina C. Herwig
    Nicole Eter
    Spektrum der Augenheilkunde, 2012, 26 : 172 - 174
  • [29] Choroidal thickness and intraocular pressure after 25-gauge and 23-gauge vitrectomy for idiopathic epiretinal membrane
    Asuka Takeyama
    Yutaka Imamura
    Masaki Shibata
    Yuko Komiya
    Goji Tomita
    Masahiro Ishida
    Japanese Journal of Ophthalmology, 2020, 64 : 22 - 27
  • [30] Choroidal thickness and intraocular pressure after 25-gauge and 23-gauge vitrectomy for idiopathic epiretinal membrane
    Takeyama, Asuka
    Imamura, Yutaka
    Shibata, Masaki
    Komiya, Yuko
    Tomita, Goji
    Ishida, Masahiro
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2020, 64 (01) : 22 - 27