25-, 23-, and 20-gauge vitrectomy in epiretinal membrane surgery: a comparative study of 553 cases

被引:71
|
作者
Sandali, Otman [1 ]
El Sanharawi, Mohamed [1 ]
Lecuen, Nicolas [1 ]
Barale, Pierre-Olivier [1 ]
Bonnel, Sebastien [1 ]
Basli, Elena [1 ]
Borderie, Vincent [1 ]
Laroche, Laurent [1 ]
Monin, Claire [1 ]
机构
[1] Ctr Hosp Natl Ophtalmol XV XX, F-75571 Paris, France
关键词
20-gauge; 23-gauge; 25-gauge; Vitrectomy; Epiretinal membrane; Visual improvement; Complication; TRANSCONJUNCTIVAL SUTURELESS VITRECTOMY; PARS-PLANA VITRECTOMY; INTRAOCULAR-PRESSURE ELEVATION; POSTOPERATIVE COMPLICATIONS; CORNEAL TOPOGRAPHY; 23-GAUGE; 25-GAUGE; ENDOPHTHALMITIS; SYSTEM; OUTCOMES;
D O I
10.1007/s00417-011-1752-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare the safety and functional outcomes of 25-gauge and 23-gauge (G) micro-incision vitrectomy surgery (MIVS) instrumentation with the standard 20-G vitrectomy system in the treatment of epiretinal membranes (ERM). A retrospective comparative study of 553 consecutive cases with epiretinal membrane who underwent pars plana vitrectomy. Twenty-gauge, 25-gauge and 23-gauge vitrectomy was performed respectively in 347, 91, and 115 eyes. Surgery duration, visual acuity improvement, intraocular pressure variation, intraoperative and postoperative complications were analyzed. The mean surgical time in the 23-G group and in the 25-G group was shorter than in the 20-G group (P < 0.001). Visual improvement was higher 8 days postoperatively in the 25-G group than in the 20-G and 23-G groups (P = 0.035), but not at 6 weeks postoperatively (P = 0.186). In the 20-G group, the IOP increased significantly on the first day postoperatively (P < 0.001), while in the 23-G group, the IOP decreased on the first day postoperatively (P = 0.073). In the 25-G group, the IOP did not change significantly (P = 0.807). The incidence of complications was not statistically significant between the three groups. Retinal breaks were significantly related to the induction of posterior vitreous detachment, independent of the system gauge. In ERM surgery, 23-G and 25-G (MIVS) systems are as safe and effective as the 20-G system, and significantly reduce surgical time. Although the 25-G system provides an earlier visual improvement, the 23- and 25- gauge systems are comparable, and the selection will depend on the surgeon's preference.
引用
收藏
页码:1811 / 1819
页数:9
相关论文
共 50 条
  • [1] 25-, 23-, and 20-gauge vitrectomy in epiretinal membrane surgery: a comparative study of 553 cases
    Otman Sandali
    Mohamed El Sanharawi
    Nicolas Lecuen
    Pierre-Olivier Barale
    Sebastien Bonnel
    Elena Basli
    Vincent Borderie
    Laurent Laroche
    Claire Monin
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 1811 - 1819
  • [2] 25-, 23-, or 20-gauge instrumentation for vitreous surgery?
    G A Williams
    Eye, 2008, 22 : 1263 - 1266
  • [3] TWENTY-THREE-GAUGE AND 20-GAUGE VITRECTOMY IN EPIRETINAL MEMBRANE SURGERY
    Haas, Anton
    Seidel, Gerald
    Steinbrugger, Iris
    Maier, Richard
    Gasser-Steiner, Vanessa
    Wedrich, Andreas
    Weger, Martin
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2010, 30 (01): : 112 - 116
  • [4] Intraoperative Retinal Break Formation in 23-/25-Gauge Vitrectomy versus 20-Gauge Vitrectomy
    Neuhann, Irmingard M.
    Hilgers, Ralf-Dieter
    Bartz-Schmidt, Karl-Ulrich
    OPHTHALMOLOGICA, 2013, 229 (01) : 50 - 53
  • [5] Comparison of 25, 23 and 20-gauge vitrectomy
    Spirn, Marc J.
    CURRENT OPINION IN OPHTHALMOLOGY, 2009, 20 (03) : 195 - 199
  • [6] 23-gauge versus 20-gauge vitrectomy: analysis of 110 consecutive cases undergoing epiretinal membrane peeling and macular hole repair
    Herwig, Martina C.
    Eter, Nicole
    SPEKTRUM DER AUGENHEILKUNDE, 2012, 26 (03) : 172 - 174
  • [7] COMPARISON OF SURGICAL OUTCOME OF 23-GAUGE AND 25-GAUGE MICROINCISION VITRECTOMY SURGERY FOR MANAGEMENT OF IDIOPATHIC EPIRETINAL MEMBRANE IN PSEUDOPHAKIC EYES
    Kim, Min
    Park, Yong Sik
    Lee, Dong Hyun
    Koh, Hyoung Jun
    Lee, Sung Chul
    Kim, Sung Soo
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2015, 35 (10): : 2115 - 2120
  • [8] Comparative study of 25- versus 20-gauge pars plana capsulotomy and vitrectomy in pediatric cataract surgery
    Anju Rastogi
    Manisha Mishra
    Yashpal Goel
    Prolima Thacker
    International Ophthalmology, 2018, 38 : 157 - 161
  • [9] Twenty five-gauge sutureless vitrectomy versus 20-gauge vitrectomy in epiretinal membrane surgery
    Sayed, Khulood Mohammed
    Naito, Takeshi
    Farouk, Mahmoud Mohamed
    Nagasawa, Toshihiko
    Katome, Takashi
    Abd El-Latif, Ismail Mousa
    Abdallah, Ahmad Mostafa
    Mohamed, Usama Ali
    Mitamura, Yoshinori
    JOURNAL OF MEDICAL INVESTIGATION, 2012, 59 (1-2) : 69 - 78
  • [10] Comparative analysis of 23-, 25-, and 27-gauge forceps stiffness and related displacement
    Pastore, Marco R.
    De Giacinto, Chiara
    Cirigliano, Gabriella
    Turco, Gianluca
    Borelli, Massimo
    Tognetto, Daniele
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (03) : 1313 - 1319