Biomechanical comparison of four different fixation methods in the management of Pauwels type III femoral neck fractures: Is there a clear winner?

被引:9
|
作者
Yildirim, Cem [1 ]
Demirel, Mehmet [2 ]
Karahan, Goekhan [1 ]
Cetinkaya, Engin [3 ]
Misir, Abduelhamit [4 ]
Yamak, Fatih [5 ]
Bozdag, Erguen [5 ]
机构
[1] Univ Hlth Sci, Basaksehir Cam & Sakura City Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[2] Istanbul Univ, Istanbul Sch Med, Dept Orthoped & Traumatol, Istanbul, Turkey
[3] Bahcesehir Univ, Medicalpark Goztepe Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[4] Medicana Int Istanbul Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[5] Istanbul Tech Univ, Fac Mech Engn Strength Mat & Biomech, Istanbul, Turkey
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2022年 / 53卷 / 10期
关键词
Pauwels type III femoral neck fractures; Cannulated screws; Medial buttress plate; Inverted triangle configuration; Distal unicortical; Distal bicortical screw placement; MEDIAL BUTTRESS PLATE; CANNULATED SCREW; INTRACAPSULAR FRACTURES; HIP SCREW;
D O I
10.1016/j.injury.2022.06.029
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Cannulated screws augmented with the medial buttress plate could confer greater biomechanical stability and higher union rates than the screw fixation alone for treating young patients with Pauwels type III femoral neck fractures (FNFs). No study has evaluated the effects of distal bicortical screw fixation and biomechanical properties of buttress plate augmentation under simultaneous vertical and rotational forces, physiologically acting on the hip joint. This study aimed to compare the biomechanical properties of four methods of three cannulated screw fixation under the combined axial and torsional loading in a synthetic femur model of type III FNF.Methods: Twenty-four third-generation composite femora were divided into four groups (6 femora in each group) based on the screw fixation configuration: inverted triangle configuration ( Group A ), Pauwels' configuration ( Group B ), inverted triangle configuration combined with medial buttress plate using distal unicortical ( Group C ), and distal bicortical screw placement ( Group D ). A Pauwels type III FNF was simulated on the sawbones. Each model was subjected to the combined axial and torsional cyclic loading and subsequently tested to failure.Result: Significant differences were determined in axial stiffness (AS) among the four groups ( p = 0.024), whereas there was no significant difference in torsional stiffness ( p = 0.147). The mean AS was higher in group D (639.5 +/- 86.2 N/mm) than in group A (430.6 +/- 94.8 N/mm), group B (426.2 +/- 41.9 N/mm), and group C (451.2 +/- 156.7 N/mm). Failure forces (FFs) were significantly different among four groups ( p = 0.007), while there was no considerable difference in failure moment values ( p = 0.555). The mean FF was significantly higher in group D (1307.1 +/- 96.4 N) than in group A (1076.9 +/- 371.2 N) and group B (1075.5 +/- 348.3 N) ( p = 0.014 and p = 0.018, respectively). There was no significant difference in the mean FF between groups D and C.Conclusion: Regardless of the medial plate use, multiple cannulated systems could provide similar biomechanical results regarding torsional stiffness and failure moments. Bicortical placement of the most distal screw in medial buttress plate application could improve axial stability but not significantly affect the rotational stability of the inverted triangle screw fixation system in managing type III FNFs.(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3124 / 3129
页数:6
相关论文
共 36 条
  • [21] Biomechanical effects of internal fixation with self-lock compression anti-rotation blade for Pauwels type III femoral neck fractures: a comparative finite element analysis
    Huang, Bo-Xuan
    Zhan, Si-Zheng
    Yang, Ming
    Zhang, Dian-Ying
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [22] Treatment of Pauwels type III femoral neck fracture with medial femoral neck support screw: a biomechanical and clinical study
    Gao, Zhichao
    Wang, Mei
    Shen, Baojie
    Chu, Xiaodong
    Ruan, Di
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [23] Biomechanical and clinical evaluation of interlocking hip screw in Pauwels III femoral neck fractures: A comparison with inverted triangle cannulated screws
    Zhang, Jian
    Jiang, Haozheng
    Dai, Wei
    Hersi, Salad Abdirahman
    Cheong, John Chun Tien Chui Wan
    Chu, Zhenchen
    Lou, Zhiyuan
    Zhang, Deqiang
    Liu, Changjian
    Tian, Kang
    Tang, Xin
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [24] Comparison of augmentation effects of medial buttress plate versus trochanteric lag screw in the cannulated screw fixation of Pauwels type III femoral neck fractures: A retrospective clinical study
    Shen, Longxiang
    Ye, Kai
    An, Zhiquan
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2023, 57 (05) : 250 - 257
  • [25] Biomechanical effects of internal fixation with self-lock compression anti-rotation blade for Pauwels type III femoral neck fractures: a comparative finite element analysis
    Bo-Xuan Huang
    Si-Zheng Zhan
    Ming Yang
    Dian-Ying Zhang
    BMC Musculoskeletal Disorders, 24
  • [26] Evaluating three internal fixation techniques for Pauwels III femoral neck fractures via finite element analysis
    Li, Ning
    Cheng, Kai-Yuan
    Fan, Jixing
    Li, Yu
    Yang, Minghui
    Zhu, Shiwen
    Jiang, Xieyuan
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [27] Internal fixation of undisplaced femoral neck fractures in the elderly: A retrospective comparison of fixation methods
    Lee, Yih-Shiunn
    Chen, Shih-Hao
    Tsuang, Yang-Hwei
    Huang, Hui-Ling
    Lo, Ting-Ying
    Huang, Chien-Rae
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (01): : 155 - 162
  • [28] Publication trends and hotspots in the research of Pauwels type III femoral neck fractures: A bibliometric and visualized analysis
    Chang, Xiaohu
    Jia, Peng
    Xu, Tao
    Tang, Xin
    ASIAN JOURNAL OF SURGERY, 2025, 48 (02) : 1171 - 1172
  • [29] Effect of three cannulated compression screws combined with an obstructing screw on the biomechanical performance of pauwels type III femoral neck fractures: a finite element analysis
    Er-dan Huang
    Huo-huo Xue
    Liang Chen
    Yang Feng
    Liang Zhao
    Zhi-Hui Zhong
    Ming Zheng
    BMC Musculoskeletal Disorders, 26 (1)
  • [30] Methods of fixation used in management of femoral neck fractures in adults: a systematic review
    Rahman, Amr Farouk Abdel
    Gouda, Ayman
    Ibrahim, Ramy
    CURRENT ORTHOPAEDIC PRACTICE, 2018, 29 (04): : 378 - 383