Mapping the thickness of retinal layers using Spectralis spectral domain optical coherence tomography in Indian eyes

被引:4
|
作者
Najeeb, Shaista [1 ]
Ganne, Pratyusha [1 ]
Damagatla, Manikanta [1 ]
Chaitanya, Ganne [2 ]
Krishnappa, Nagesha C. [3 ]
机构
[1] All India Inst Med Sci, Dept Ophthalmol, Guntur 522503, Andhra Pradesh, India
[2] Univ Texas Hlth Sci Ctr Houston, Dept Neurol, Houston, TX 77030 USA
[3] BW Lions Superspecial Eye Hosp, Dept Vitreo Retina, Bengaluru, Karnataka, India
关键词
Age; gender; macular layers; normative; optical coherence tomography; thickness; NERVE-FIBER LAYER; AXIAL LENGTH; MACULAR THICKNESS; AGE; SEX; OCT;
D O I
10.4103/ijo.IJO_81_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: This study aimed at establishing the normative data for the thickness of macular layers on Spectralis Spectral-domain optical coherence tomography (SD-OCT) in healthy Indian eyes and testing the effects of age, gender, central corneal thickness (CCT), and intraocular pressure (IOP) on such values. Methods: This cross-sectional study was done on 308 eyes of 159 healthy subjects. OCT scans were obtained using the posterior pole asymmetry scan protocol. From the thickness map, data were grouped into nine Early Treatment Diabetic Retinopathy Study (ETDRS) macular sectors. Correlation between retinal thickness and age/IOP/CCT was done using Pearson correlation. Correcting for age as a covariate, multivariate regression analysis was done to know which retinal layers showed significant differences in thickness between males and females. Results: The mean age was 46.06 +/- 13.06 years (range: 20-75 years). Significant central subfield (CSF) thickening with age was noted in retinal nerve fiber layer (RNFL), inner nuclear layer (IPL), inner nudear layer (INL), outer plexiform layer (OPL), and outer nuclear layer (ONL) (P < 0.04). The average thickness of the outer ring reduced with age in the ganglion cell layer (GCL)/IPL/INL (P = 0.001). Women had thinner inner and outer retinal thickness than men in all ETDRS rings (P < 0.001). There was no interocular asymmetry (P > 0.05) and no correlation between IOP/CCT and retinal layer thickness. Conclusion: In CSF, age-related thickening was noted in RNFL, IPL, INL, OPL, and ONL. The average inner ring thickness decreased with age in GCL and IPL and increased in the RPE layer. The average outer ring thickness decreased with age in GCL, IPL, and INL layers and increased in OPL. The average IR and OR thickness was significantly less in women compared to men in all sub-fields. There was no correlation between IOP/CCT and retinal layer thickness.
引用
收藏
页码:2990 / 2997
页数:8
相关论文
共 50 条
  • [1] Macular thickness and volume of myopic eyes measured using spectral-domain optical coherence tomography
    Hwang, Young Hoon
    Kim, Yong Yeon
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2012, 95 (05) : 492 - 498
  • [2] Retinal thickness of myopic eyes determined by spectralis optical coherence tomography
    Sato, Atsuko
    Fukui, Emi
    Ohta, Kouichi
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (12) : 1624 - 1628
  • [3] Reference Database of Inner Retinal Layer Thickness and Thickness Asymmetry in Healthy Thai Adults as Measured by the Spectralis Spectral-Domain Optical Coherence Tomography
    Choovuthayakorn, Janejit
    Chokesuwattanaskul, Susama
    Phinyo, Phichayut
    Hansapinyo, Linda
    Pathanapitoon, Kessara
    Chaikitmongkol, Voraporn
    Watanachai, Nawat
    Kunavisarut, Paradee
    Patikulsila, Direk
    OPHTHALMIC RESEARCH, 2022, 65 (06) : 668 - 677
  • [4] Evaluation of myopia on retinal nerve fiber layer thickness measured by Spectralis optical coherence tomography
    Zha, Yi
    Zhuang, Jinfei
    Lin, Da
    Feng, Wangqiang
    Zheng, Haihua
    Cai, Jianqiu
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (03) : 2716 - 2720
  • [5] Determinants of Macular Thickness Using Spectral Domain Optical Coherence Tomography in Healthy Eyes: The Singapore Chinese Eye Study
    Gupta, Preeti
    Sidhartha, Elizabeth
    Tham, Yih Chung
    Chua, Daniel Kai Peng
    Liao, Jiemin
    Cheng, Ching-Yu
    Aung, Tin
    Wong, Tien Yin
    Cheung, Carol Y.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (13) : 7968 - 7976
  • [6] Retinal nerve fibre layer thickness measured by Spectralis spectral-domain optical coherence tomography: The Beijing Eye Study
    Zhao, Liang
    Wang, Yaxing
    Chen, Chang X.
    Xu, Liang
    Jonas, Jost B.
    ACTA OPHTHALMOLOGICA, 2014, 92 (01) : E35 - E41
  • [7] Comparison of spectral-domain optical coherence tomography for intra-retinal layers thickness measurements between healthy and diabetic eyes among Chinese adults
    Li, Shu-ting
    Wang, Xiang-ning
    Du, Xin-hua
    Wu, Qiang
    PLOS ONE, 2017, 12 (05):
  • [8] Macular thickness measured by spectral-domain optical coherence tomography in healthy Thai eyes
    Choovuthayakorn, Janejit
    Watanachai, Nawat
    Chaikitmongkol, Voraporn
    Patikulsila, Direk
    Kunavisarut, Paradee
    Ittipunkul, Nimitr
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2012, 56 (06) : 569 - 576
  • [9] Profile and Determinants of Retinal Optical Intensity in Normal Eyes with Spectral Domain Optical Coherence Tomography
    Chen, Binyao
    Gao, Enting
    Chen, Haoyu
    Yang, Jianling
    Shi, Fei
    Zheng, Ce
    Zhu, Weifang
    Xiang, Dehui
    Chen, Xinjian
    Zhang, Mingzhi
    PLOS ONE, 2016, 11 (02):
  • [10] Effect of Age on Individual Retinal Layer Thickness in Normal Eyes as Measured With Spectral-Domain Optical Coherence Tomography
    Demirkaya, Nazli
    van Dijk, Hille W.
    van Schuppen, Sanne M.
    Abramoff, Michael D.
    Garvin, Mona K.
    Sonka, Milan
    Schlingemann, Reinier O.
    Verbraak, Frank D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (07) : 4934 - 4940