Retinal nerve fiber structure versus visual field function in patients with ischemic optic neuropathy - A test of a linear model

被引:83
作者
Hood, Donald C. [1 ,2 ]
Anderson, Susan [3 ]
Rouleau, Jacinthe [3 ]
Wenick, Adam S. [1 ,2 ]
Grover, Larissa K. [1 ]
Behrens, Myles M. [2 ]
Odel, Jeffrey G.
Lee, Andrew G. [3 ]
Kardon, Randy H. [3 ]
机构
[1] Columbia Univ, Dept Psychol, New York, NY 10027 USA
[2] Columbia Univ, Dept Ophthalmol, New York, NY 10027 USA
[3] Univ Iowa & Vet Adm, Dept Ophthalmol, Iowa City, IA USA
关键词
D O I
10.1016/j.ophtha.2007.06.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To test a linear model relating the regional loss in retinal nerve fiber (RNFL) thickness to the corresponding regional loss in sensitivity with data from patients with previous anterior ischemic optic neuropathy (AION). Design: Case-control study. Participants: Twenty-four individuals with AION and 20 with normal vision were tested. The time since the AION attack ranged from 5.2 months to more than 20.3 years (median, 2.95 years). Methods: Eyes were tested with standard automated perimetry (SAP) and with optical coherence tomography (OCT), both RNFL thickness scans. The average RNFL thickness of the inferior and superior disc sectors was plotted against the average total deviations (linear units) of the corresponding superior and inferior arcuate field regions, and a linear model was fitted. According to the model, the RNFL thickness R = s(0)T + b, (1), where T is the relative SAP sensitivity loss (on a linear scale; e.g., for -3 dB, T = 0.5), s(o) is the RNFL thickness attributable to axons in the healthy or normal state (T = 1.0), and b is the residual RNFL measured when all sensitivity and axons are lost. Main Outcome Measures: Optical coherence tomography RNFL thickness and SAP sensitivity. Results: The data from the AION patients resembled the data from glaucoma patients previously tested and were described by the linear model. For patients with SAP losses of more than -10 dB in the arcuate region, the RNFL thickness provided an estimate of residual RNFL thickness, b. The median value of b (45.5 mu m) was similar to the value for patients with glaucoma. It varied among individuals (range, 30.4-63.3 mu m), showing a very weak correlation with patient's age (r = 0.30) and the time since the AION episode (r = 0.26), but an excellent correlation (r(2) = 0.94; P<0.01) with the value of s(o), estimated from the unaffected eyes. Conclusions: The relationship between a structure (OCT RNFL thickness) and function (SAP sensitivity loss) is the same for patients with AION and glaucoma and can be approximated by a simple linear model. The model may provide a framework for identifying those patients with ganglion cell axons that are malfunctioning but are alive.
引用
收藏
页码:904 / 910
页数:7
相关论文
共 27 条
  • [1] THE EFFECT OF AGE ON THE NERVE-FIBER POPULATION OF THE HUMAN OPTIC-NERVE
    BALAZSI, AG
    ROOTMAN, J
    DRANCE, SM
    SCHULZER, M
    DOUGLAS, GR
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1984, 97 (06) : 760 - 766
  • [2] Structure-function relationships using confocal scanning laser ophthalmoscopy, optical coherence tomography, and scanning laser polarimetry
    Bowd, Christopher
    Zangwill, Linda M.
    Medeiros, Felipe A.
    Tavares, Ivan M.
    Hoffmann, Esther M.
    Bourne, Rupert R.
    Sample, Pamela A.
    Weinreb, Robert N.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (07) : 2889 - 2895
  • [3] Reliability of nerve fiber layer thickness measurements using optical coherence tomography in normal and glaucomatous eyes
    Carpineto, P
    Ciancaglini, M
    Zuppardi, E
    Falconio, G
    Doronzo, E
    Mastropasqua, L
    [J]. OPHTHALMOLOGY, 2003, 110 (01) : 190 - 195
  • [4] Retinal nerve fiber layer thickness measured with optical coherence tomography is related to visual function in glaucomatous eyes
    El Beltagi, TA
    Bowd, C
    Boden, C
    Amini, P
    Sample, PA
    Zangwill, LM
    Weinreb, RN
    [J]. OPHTHALMOLOGY, 2003, 110 (11) : 2185 - 2191
  • [5] Garway-Heath DF, 2004, GLAUCOMA DIAGNOSIS STRUCTURE AND FUNCTION, P135
  • [6] Garway-Heath DF, 2002, INVEST OPHTH VIS SCI, V43, P2213
  • [7] Mapping the visual field to the optic disc in normal tension glaucoma eyes
    Garway-Heath, DF
    Poinoosawmy, D
    Fitzke, FW
    Hitchings, RA
    [J]. OPHTHALMOLOGY, 2000, 107 (10) : 1809 - 1815
  • [8] Optical coherence tomography measurement of macular and nerve fiber layer thickness in normal and glaucomatous human eyes
    Guedes, V
    Schuman, JS
    Hertzmark, E
    Wollstein, G
    Correnti, A
    Mancini, R
    Lederer, D
    Voskanian, S
    Velazquez, L
    Pakter, HM
    Pedut-Kloizman, T
    Fujimoto, JG
    Mattox, C
    [J]. OPHTHALMOLOGY, 2003, 110 (01) : 177 - 189
  • [9] The relationship between nerve fiber layer and perimetry measurements
    Harwerth, Ronald S.
    Vilupuru, Abhiram S.
    Rangaswamy, Nalini V.
    Smith, Earl L., III
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (02) : 763 - 773
  • [10] Hood DC, 2002, ARCH OPHTHALMOL-CHIC, V120, P1672