Simulation of absorbed dose, in molecular therapy, by means of Monte Carlo method using free software GEANT4: GATE

被引:0
作者
Echevarria Torres, Waldo Jose [1 ]
Manso Nobrega, Weiner [2 ]
Gonzalez Gonzalez, Joaquin [3 ]
Fragoso Negrin, Jose Alejandro [4 ]
机构
[1] Univ Cent Las Villas, Santa Clara, Villa Clara, Cuba
[2] Inst Tecnol Aguascalientes, Aguascalientes, Aguascalientes, Mexico
[3] Inst Nacl Oncol & Radiobiol, Havana, La Habana, Cuba
[4] Inst Super Tecnol & Ciencias Aplicadas, Havana, La Habana, Cuba
来源
MEDISUR-REVISTA DE CIENCIAS MEDICAS DE CIENFUEGOS | 2022年 / 20卷 / 02期
关键词
radiotherapy; radiation dosage; absorption; radiation; simulation technique; Monte Carlo Method;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: there is still no optimal way to determine the dose absorbed by tumors; this lack of knowledge is the reason why the final dose of treatment is unpredictable. For this reason, patients may be receiving doses greater than the minimum required for their correct diagnosis. Objective: to create a source code for an application project of the GATE program in the simulation of absorbed dose in molecular radiotherapy, by Monte Carlo method, for a Giap phantom. Methods: the simulation was carried out by the Montecarlo method from modeling the Giap phantom, using the GATE simulation platform. The results obtained were compared with the information reflected in the bibliography on standardized best practices. Results: a source code implemented in GATE was prepared for the determination of the absorbed dose in molecular radiotherapy. Non-uniform distribution of doses was obtained in a medium with uniform activity and an approximate 2% uncertainty (in correspondence with the values reported in the literature), the results allow to affirm that the dose simulation through the GATE platform is reliable, of little computational expense and highly recommended. Conclusions: it is advisable to use the GATE platform for the simulation of the calculation of the absorbed dose because it is fast, of low computational cost and reliable.
引用
收藏
页码:222 / 231
页数:10
相关论文
共 50 条
[41]   Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method [J].
Entezam, Amir ;
Fielding, Andrew ;
Bradley, David ;
Fontanarosa, Davide .
PLOS ONE, 2023, 18 (02)
[42]   Dosimetric Analysis of Rhizophora-based Phantom Material in Radiation Therapy Applications Using Monte Carlo GATE Simulation [J].
Zuber, Siti Hajar ;
Hadi, Muhammad Fahmi Rizal Abdul ;
Samson, Damilola Oluwafemi ;
Jayamani, Jayapramila ;
Rabaiee, Nor Ain ;
Aziz, Mohd Zahri Abdul ;
Hashikin, Nurul Ab. Aziz ;
Ying, Chee Keat ;
Yusof, Mohd Fahmi Mohd ;
Hashim, Rokiah .
JOURNAL OF MEDICAL PHYSICS, 2023, 48 (04) :358-364
[43]   The effect of 111In radionuclide distance and auger electron energy on direct induction of DNA double-strand breaks: a Monte Carlo study using Geant4 toolkit [J].
Piroozfar, Behnaz ;
Raisali, Gholamreza ;
Alirezapour, Behrouz ;
Mirzaii, Mohammad .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2018, 94 (04) :385-393
[44]   Computational Simulation of Temperature Elevations in Tumors Using Monte Carlo Method and Comparison to Experimental Measurements in Laser Photothermal Therapy [J].
Manuchehrabadi, Navid ;
Chen, Yonghui ;
LeBrun, Alexander ;
Ma, Ronghui ;
Zhu, Liang .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (12)
[45]   ANALYSIS OF FREE MOLECULAR-FLOW IN A TUBE OF FINITE LENGTH USING THE TIME-TRANSIENT MONTE-CARLO METHOD [J].
SESE, M ;
KAWAMURA, Y .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1990, 23 (02) :137-143
[46]   INVESTIGATION OF A PRACTICAL PATIENT DOSE INDEX FOR ASSESSMENT OF PATIENT ORGAN DOSE FROM CONE-BEAM COMPUTED TOMOGRAPHY IN RADIATION THERAPY USING A MONTE CARLO SIMULATION [J].
Kamezawa, H. ;
Arimura, H. ;
Arakawa, H. ;
Kameda, N. .
RADIATION PROTECTION DOSIMETRY, 2018, 181 (04) :333-342
[47]   Effective dose estimation in cone-beam computed tomography for dental use by Monte-Carlo simulation optimizing calculation numbers using a step-and-shoot method [J].
Ozaki, Yoshihiro ;
Watanabe, Hiroshi ;
Kurabayashi, Tohru .
DENTOMAXILLOFACIAL RADIOLOGY, 2021, 50 (07)
[48]   Measurement-based Monte Carlo simulation of high definition dose evaluation for nasopharyngeal cancer patients treated by using intensity modulated radiation therapy [J].
Yeh, C. Y. ;
Tung, C. J. ;
Lee, C. C. ;
Lin, M. H. ;
Chao, T. C. .
RADIATION MEASUREMENTS, 2014, 71 :333-337
[49]   ANALYSIS OF FLOW PROPERTIES IN A COMPOSITE ROUND TUBE UNDER FREE MOLECULAR-FLOW USING THE TIME TRANSIENT MONTE-CARLO METHOD [J].
SESE, M ;
KAWAMURA, Y .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1990, 23 (06) :768-769
[50]   Dose profiles and x-ray energy optimization for microbeam radiation therapy by high-dose, high resolution dosimetry using Sm-doped fluoroaluminate glass plates and Monte Carlo transport simulation [J].
Chicilo, F. ;
Hanson, A. L. ;
Geisler, F. H. ;
Belev, G. ;
Edgar, A. ;
Ramaswami, K. O. ;
Chapman, D. ;
Kasap, S. O. .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (07)