Simulation of absorbed dose, in molecular therapy, by means of Monte Carlo method using free software GEANT4: GATE

被引:0
|
作者
Echevarria Torres, Waldo Jose [1 ]
Manso Nobrega, Weiner [2 ]
Gonzalez Gonzalez, Joaquin [3 ]
Fragoso Negrin, Jose Alejandro [4 ]
机构
[1] Univ Cent Las Villas, Santa Clara, Villa Clara, Cuba
[2] Inst Tecnol Aguascalientes, Aguascalientes, Aguascalientes, Mexico
[3] Inst Nacl Oncol & Radiobiol, Havana, La Habana, Cuba
[4] Inst Super Tecnol & Ciencias Aplicadas, Havana, La Habana, Cuba
来源
MEDISUR-REVISTA DE CIENCIAS MEDICAS DE CIENFUEGOS | 2022年 / 20卷 / 02期
关键词
radiotherapy; radiation dosage; absorption; radiation; simulation technique; Monte Carlo Method;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: there is still no optimal way to determine the dose absorbed by tumors; this lack of knowledge is the reason why the final dose of treatment is unpredictable. For this reason, patients may be receiving doses greater than the minimum required for their correct diagnosis. Objective: to create a source code for an application project of the GATE program in the simulation of absorbed dose in molecular radiotherapy, by Monte Carlo method, for a Giap phantom. Methods: the simulation was carried out by the Montecarlo method from modeling the Giap phantom, using the GATE simulation platform. The results obtained were compared with the information reflected in the bibliography on standardized best practices. Results: a source code implemented in GATE was prepared for the determination of the absorbed dose in molecular radiotherapy. Non-uniform distribution of doses was obtained in a medium with uniform activity and an approximate 2% uncertainty (in correspondence with the values reported in the literature), the results allow to affirm that the dose simulation through the GATE platform is reliable, of little computational expense and highly recommended. Conclusions: it is advisable to use the GATE platform for the simulation of the calculation of the absorbed dose because it is fast, of low computational cost and reliable.
引用
收藏
页码:222 / 231
页数:10
相关论文
共 49 条
  • [1] The accuracy of out of field dose calculations in commercial treatment planning system using GATE/GEANT4 Monte Carlo simulation
    Attalla, Ehab Marouf
    Sinousy, Dina Mohamed
    Ibrahim, Hassan Fathy
    Elhussiny, Fathi Ahmed
    Elmekawy, Ahmed Farouk
    RADIATION PHYSICS AND CHEMISTRY, 2023, 206
  • [2] Geant4 Monte Carlo simulation of absorbed dose and radiolysis yields enhancement from a gold nanoparticle under MeV proton irradiation
    Tran, H. N.
    Karamitros, M.
    Ivanchenko, V. N.
    Guatelli, S.
    McKinnon, S.
    Murakami, K.
    Sasaki, T.
    Okada, S.
    Bordage, M. C.
    Francis, Z.
    El Bitar, Z.
    Bernal, M. A.
    Shin, J. I.
    Lee, S. B.
    Barberet, Ph.
    Tran, T. T.
    Brown, J. M. C.
    Hao, T. V. Nhan
    Incerti, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 373 : 126 - 139
  • [3] Monte Carlo simulation of NovalisTx linear accelerator using GATE/Geant4 code for dosimetry analysis
    Fathi, Ahmed
    Khobbaizi, Youness
    Nabil, Sanaa
    Ardouz, Anas
    Hasnaoui, Abdellatif
    Sbiaai, Khalid
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 466 - 472
  • [4] Application of Geant4 Monte Carlo simulation in dose calculations for small radiosurgical fields
    Gholami, Somayeh
    Longo, Francesco
    Nedaie, Hassan Ali
    Berti, Alessio
    Mousavi, Mehdi
    Meigooni, Ali S.
    MEDICAL DOSIMETRY, 2018, 43 (03) : 214 - 223
  • [5] Study of Dose Enhancement Effects in the Vicinity of High Z Atoms with Geant4 Monte Carlo Simulation
    Huang, Ke
    Yan, Kaiguo
    Yu, Yan
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 1260 - 1264
  • [6] A Monte Carlo pencil beam scanning model for proton treatment plan simulation using GATE/GEANT4
    Grevillot, L.
    Bertrand, D.
    Dessy, F.
    Freud, N.
    Sarrut, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16): : 5203 - 5219
  • [7] Applications of the Monte Carlo method in nuclear physics using the GEANT4 toolkit
    Moralles, Mauricio
    Guimaraes, Carla C.
    Bonifacio, Daniel A. B.
    Okuno, Emico
    Murata, Helio M.
    Bottaro, Marcio
    Menezes, Mario O.
    Guimaraes, Valdir
    NUCLEAR PHYSICS 2008: XXXI WORKSHOP ON NUCLEAR PHYSICS IN BRAZIL, 2009, 1139 : 51 - +
  • [8] Monte Carlo simulation of laser beams interaction with the human eye using Geant4
    Diogo Tendeiro
    Gonçalo Lopes
    Pedro Vieira
    José Paulo Santos
    BioMedical Engineering OnLine, 13
  • [9] Monte Carlo simulation of laser beams interaction with the human eye using Geant4
    Tendeiro, Diogo
    Lopes, Goncalo
    Vieira, Pedro
    Santos, Jose Paulo
    BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [10] GMC: a GPU implementation of a Monte Carlo dose calculation based on Geant4
    Jahnke, Lennart
    Fleckenstein, Jens
    Wenz, Frederik
    Hesser, Juergen
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05): : 1217 - 1229