A Practical Approach to Using Quality Indicators in Continuous Quality Improvement Processes in a Medical Laboratory

被引:1
|
作者
David, Remona E. [1 ]
Dobreanu, Minodora [1 ,2 ]
机构
[1] George Emil Palade Univ Med Pharm Sci & Technol T, Dept Lab Med, 38 Gheorghe Marinescu St, Targu Mures 540139, Romania
[2] George Emil Palade Univ Med Pharm Sci & Technol T, Adv Ctr Med & Pharmaceut Res CCAMF, Targu Mures, Romania
关键词
quality indicator; FMEA; FRACAS; Six Sigma; RISK;
D O I
10.7754/Clin.Lab.2021.210339
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The obligation of implementing the terms "risk management" and "quality indicators" led us to understand and apply them in the best possible way. The purpose of our study was to establish a guide of selection and usage of quality indicators (QIs)/key performance indicators (KPIs) in a Romanian medical laboratory. Methods: The study group consisted of all analysis requests received by the Biochemistry Department of the laboratory between January 1st, 2015, and December 31st, 2018. The first stage of the study took place between January 1st, 2015, and December 31st, 2015, when the QIs/KPIs were selected for the pre-analytical process by risk management techniques and evaluation guide for the QIs/KPIs was developed. After their establishment, we checked, using data of the pre-analytical QIs of a previous stage, if the claims and the initially established limits were specific, objective, and attainable. In the second stage of the study the data were collected prospectively. Monthly values, percentages, and sigma values of selected QIs/KPIs were calculated. QI percentages were compared to the IFCC performance specifications and the limits established by the laboratory. Results: The frequency of total defects of samples was 3.45%, the Six Sigma value was 3.4 for the Biochemistry Department. The highest rates were observed for the lipemic (1.92%) and hemolyzed samples (1.06%) in the Biochemistry Department. Conclusions: Implementing risk management and QIs can increase the pre-analytic process performance by decreasing the risk level either through stepping up the measures of detection, or through reducing of the frequency of occurrence of nonconformities.
引用
收藏
页码:78 / 90
页数:13
相关论文
共 50 条
  • [21] Nationwide continuous quality improvement using clinical indicators: The Danish National Indicator Project
    Mainz, J
    Krog, BR
    Bjornshave, B
    Bartels, P
    INTERNATIONAL JOURNAL FOR QUALITY IN HEALTH CARE, 2004, 16 : I45 - I50
  • [22] Establishing a hospice using the continuous quality improvement (CQI) design approach
    Fabbi, P
    Foster, LL
    Herbick, J
    JOURNAL OF PALLIATIVE CARE, 1995, 11 (04) : 63 - 63
  • [23] Quality guidelines implementation using a continuous quality improvement programme
    Richards, Nick
    Ayala, Juan Antonio
    Cesare, Salvatore
    Di Benedetto, Attilio
    Gassia, Jean-Paul
    Merello, Jose Ignacio
    Rentero, Ramon
    Scatizzi, Laura
    Marcelli, Daniele
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 : 425 - 426
  • [24] Evaluation of continuous quality improvement in accreditation for medical education
    Nesibe Akdemir
    Linda N. Peterson
    Craig M. Campbell
    Fedde Scheele
    BMC Medical Education, 20
  • [25] Evaluation of continuous quality improvement in accreditation for medical education
    Akdemir, Nesibe
    Peterson, Linda N.
    Campbell, Craig M.
    Scheele, Fedde
    BMC MEDICAL EDUCATION, 2020, 20 (Suppl 1)
  • [26] Using Dashboards to Support Continuous Quality Improvement in Undergraduate and Graduate Medical Education
    Dufault, Carolyn L.
    Colson, Eve R.
    Dallaghan, Gary L. Beck
    Buchanan, April O.
    Aagaard, Eva M.
    Blaylock, Leslie
    Wroblewski, Matthew
    Osterberg, Lars
    Roman, Brenda J. B.
    Coplit, Lisa
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2025, 40 (01) : 171 - 176
  • [27] QUALITY ASSURANCE AND QUALITY CONTROL IN THE ANALYTICAL CHEMICAL LABORATORY. A PRACTICAL APPROACH
    Siepak, Jerzy
    ECOLOGICAL CHEMISTRY AND ENGINEERING A-CHEMIA I INZYNIERIA EKOLOGICZNA A, 2010, 17 (01): : 157 - 158
  • [28] A PRACTICAL APPROACH TO COMPANY-WIDE QUALITY IMPROVEMENT
    STERETT, WK
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1984, 46 : 568 - 568
  • [29] GUIDELINES FOR CONTINUOUS QUALITY IMPROVEMENT IN THE CARDIAC-CATHETERIZATION LABORATORY
    HEUPLER, FA
    ALHANI, AJ
    DEAR, WE
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 30 (03): : 191 - 200
  • [30] QUALITY INDICATORS: A TOOL FOR QUALITY MONITORING AND IMPROVEMENT
    Vuk, T.
    VOX SANGUINIS, 2012, 103 : 2 - 2