Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart

被引:171
作者
Kachelriess, M [1 ]
Kalender, WA [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
关键词
computed tomography (CT); spiral CT; heart; coronary vessels; calcium;
D O I
10.1118/1.598453
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Subsecond computed tomography (CT) scanning offers potential for improved heart imaging. We therefore developed and validated dedicated reconstruction algorithms for imaging the heart with subsecond spiral CT utilizing electrocardiogram (ECG) information. We modified spiral CT z-interpolation algorithms on a subsecond spiral CT scanner. Two new classes of algorithms were investigated: (a) 180 degrees CI (cardio interpolation), a piecewise linear interpolation between adjacent spiral data segments belonging to the same heart phase where segments are selected by correlation with the simultaneously recorded ECG signal and (b) 180 degrees CD (cardio delta), a partial scan reconstruction of 180 degrees + delta with delta< fan angle, resulting in reduced effective scan times of less than 0.5 s. Computer simulations as well as processing of clinical data collected with 0.75 s scan time were carried out to evaluate these new approaches. Both 180 degrees CI and 180 degrees CD provided significant improvements in image quality. Motion artifacts in the reconstructed images were largely reduced as compared to standard spiral reconstructions; in particular, coronary calcifications were delineated more sharply and multiplanar reformations showed improved contiguity. However, new artifacts in the image plane are introduced, mostly due to the combination of different data segments. ECG-oriented image reconstructions improve the quality of heart imaging with spiral CT significantly. Image quality and the display of coronary calcification appear adequate to assess coronary calcium measurements with conventional subsecond spiral CT. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)00712-3].
引用
收藏
页码:2417 / 2431
页数:15
相关论文
共 50 条
  • [21] Anisotropic structure property based image reconstruction method for limited-angle computed tomography
    Gong, Changcheng
    Zeng, Li
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2021, 29 (06) : 1079 - 1102
  • [22] Radiation dose management for pediatric cardiac computed tomography: a report from the Image Gently ‘Have-A-Heart’ campaign
    Cynthia K. Rigsby
    Sarah E. McKenney
    Kevin D. Hill
    Anjali Chelliah
    Andrew J. Einstein
    B. Kelly Han
    Joshua D. Robinson
    Christina L. Sammet
    Timothy C. Slesnick
    Donald P. Frush
    Pediatric Radiology, 2018, 48 : 5 - 20
  • [23] Radiation dose management for pediatric cardiac computed tomography: a report from the Image Gently 'Have-A-Heart' campaign
    Rigsby, Cynthia K.
    McKenney, Sarah E.
    Hill, Kevin D.
    Chelliah, Anjali
    Einstein, Andrew J.
    Han, B. Kelly
    Robinson, Joshua D.
    Sammet, Christina L.
    Slesnick, Timothy C.
    Frush, Donald P.
    PEDIATRIC RADIOLOGY, 2018, 48 (01) : 5 - 20
  • [24] Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time
    Shi-Zheng Zhang
    Xiu-Hua Hu
    Qiao-Wei Zhang
    Wen-Xin Huang
    European Radiology, 2005, 15 : 1105 - 1109
  • [25] Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation time
    Zhang, SZ
    Hu, XH
    Zhang, QW
    Huang, WX
    EUROPEAN RADIOLOGY, 2005, 15 (06) : 1105 - 1109
  • [26] Knowledge and Perception of Radiation Risk From Computed Tomography Scans Among Patients Attending an Emergency Department
    Alsubaie, Faisal H.
    Abujamea, Abdullah H.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [27] Adaptive statistical iterative reconstruction for volume-rendered computed tomography portovenography: improvement of image quality
    Matsuda, Izuru
    Hanaoka, Shohei
    Akahane, Masaaki
    Sato, Jiro
    Komatsu, Shuuhei
    Inoh, Shinichi
    Kiryu, Shigeru
    Yoshioka, Naoki
    Ino, Kenji
    Ohtomo, Kuni
    JAPANESE JOURNAL OF RADIOLOGY, 2010, 28 (09): : 700 - 706
  • [28] Three-Dimensional Reconstruction of Gangneung Mummy's Heart and Liver Based on the Computed Tomography Images
    Koh, Ensung
    Lee, Da Yeong
    Yoo, Dongsoo
    Kim, Myeung Ju
    Hong, Jong Ha
    Park, Sang Joon
    Kim, Jieun
    Lee, In Sun
    Shin, Dong Hoon
    ANCIENT ASIA-JOURNAL OF THE SOCIETY OF SOUTH ASIAN ARCHAEOLOGY, 2023, 14
  • [29] Noninvasive coronary artery imaging by multislice spiral computed tomography - A novel approach for a retrospectively ECG-gated reconstruction technique
    Sato, Y
    Kanmatsuse, K
    Inoue, F
    Horie, T
    Kato, M
    Kusama, J
    Yoshimura, A
    Imazeki, T
    Furuhashi, S
    Takahashi, M
    CIRCULATION JOURNAL, 2003, 67 (02) : 107 - 111
  • [30] Impact of deep learning-based image reconstruction on image quality compared with adaptive statistical iterative reconstruction-Veo in renal and adrenal computed tomography
    Bie, Yifan
    Yang, Shuo
    Li, Xingchao
    Zhao, Kun
    Zhang, Changlei
    Zhong, Hai
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (03) : 409 - 418