Contrast-Enhanced Ultrasound Imaging of Sentinel Lymph Nodes After Peritumoral Administration of Sonazoid in a Melanoma Tumor Animal Model

被引:40
作者
Goldberg, Barry B.
Merton, Daniel A. [1 ]
Liu, Ji-Bin
Forsberg, Flemming
Zhang, Kaijun
Thakur, Madhukar
Schulz, Stephanie [2 ]
Schanche, Robin [3 ]
Murphy, George F. [3 ]
Waldman, Scott A. [2 ]
机构
[1] Thomas Jefferson Univ Hosp, Dept Radiol, Div Diagnost Ultrasound, Philadelphia, PA 19107 USA
[2] Thomas Jefferson Univ Hosp, Dept Pharmacol & Expt Therapeut, Philadelphia, PA 19107 USA
[3] Brigham & Womens Hosp, Dept Pathol, Boston, MA 02115 USA
基金
美国国家卫生研究院;
关键词
characterization; contrast agent; detection; lymph node; malignancy; ultrasound; SWINE MODEL; GRAY-SCALE; BREAST; ULTRASONOGRAPHY; BIOPSY; LYMPHOSCINTIGRAPHY; METASTASES; LYMPHADENECTOMY; IDENTIFICATION; DISEASE;
D O I
10.7863/jum.2011.30.4.441
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-The purpose of this study was to compare lymphosonography (ie, contrast-enhanced ultrasound imaging [US] after interstitial injection of a US contrast agent) for the detection of sentinel lymph nodes (SLNs) in swine with naturally occurring melanoma tumors to lymphoscintigraphy using blue dye-guided surgical dissection as the reference standard. Also, we sought to determine if lymphosonography can be used to characterize SLNs. Methods-Sixty-three swine with 104 melanomas were evaluated. Contrast-specific US was performed after peritumoral injection (1 mL dose) of Sonazoid (GE Healthcare, Oslo, Norway). Lymphoscintigraphy was performed after peritumoral injections of technetium Tc 99m sulfur colloid. Peritumoral injection of 1% Lymphazurin (Ben Venue Labs, Inc, Bedford, OH) was used to guide SLN resection. The accuracy of SLN detection with the two imaging modalities was compared using the McNemar test. The SLNs were qualitatively and quantitatively characterized as benign or malignant based on the lymphosonography results with histopathology and RNA analyses used as the reference standards. Results-Blue dye-guided surgery identified 351 SLNs. Lymphosonography detected 293 SLNs and 11 false-positives, while lymphoscintigraphy detected 231 SLNs and 20 false-positives. The accuracy of SLN detection was 81.8% for lymphosonography, which was significantly higher than the 63.2% achieved with lymphoscintigraphy (P < .0001). The accuracy of lymphosonography for SLN characterization was 80%. When the size of the enhanced SLN was taken into consideration to characterize SLNs, the accuracy was 86%. Conclusions-Lymphosonography is statistically better than lymphoscintigraphy for the detection of SLNs in this animal model. The ability to use lymphosonography as a means to characterize SLNs as benign or malignant is limited.
引用
收藏
页码:441 / 453
页数:13
相关论文
共 50 条
  • [41] Ultrasound contrast-enhanced patterns of sentinel lymph nodes: predictive value for nodal status and metastatic burden in early breast cancer
    Zhu, Yangyang
    Jia, Yingying
    Pang, Wenjing
    Duan, Ying
    Chen, Kundi
    Nie, Fang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (01) : 160 - 170
  • [42] Preliminary study of real-time three-dimensional contrast-enhanced ultrasound of sentinel lymph nodes in breast cancer
    Hu, Ziyue
    Cheng, Xueqing
    Li, Juan
    Jiang, Jingzhen
    Jiang, Zirui
    Li, Hui
    Li, Tingting
    Zhang, Zhenqi
    Tan, Bo
    Lu, Man
    EUROPEAN RADIOLOGY, 2020, 30 (03) : 1426 - 1435
  • [43] Microbubble Contrast-Enhanced Ultrasound for Sentinel Lymph Node Detection: Ready for Prime Time?
    Yang, Wei Tse
    Goldberg, Barry B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (02) : 249 - 250
  • [44] Contrast-enhanced lymphatic US can improve the preoperative diagnostic performance for sentinel lymph nodes in early breast cancer
    Niu, Zihan
    Gao, Yuanjing
    Xiao, Mengsu
    Mao, Feng
    Zhou, Yidong
    Zhu, Qingli
    Jiang, Yuxin
    EUROPEAN RADIOLOGY, 2023, 33 (03) : 1593 - 1602
  • [45] Application of Contrast-Enhanced Ultrasound (CEUS) in Lymphomatous Lymph Nodes: A Comparison between PET/CT and Contrast-Enhanced CT
    Ma, Xuelei
    Ling, Wenwu
    Xia, Fan
    Zhang, Yifan
    Zhu, Chenjing
    He, Jialing
    CONTRAST MEDIA & MOLECULAR IMAGING, 2019,
  • [46] Tumor Perfusion and Neovascular Morphology Measurements using Dynamic Contrast-Enhanced Ultrasound Imaging
    Hoyt, Kenneth
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 197 - 200
  • [47] Upper gastrointestinal tract perforation assessed by contrast-enhanced ultrasonography after oral Sonazoid administration in a stomach leakage mouse model
    Jung, Kyuhwan
    Woo, Sook-Young
    Kim, A. Ran
    Kim, Honsoul
    ULTRASONOGRAPHY, 2023, 42 (02) : 297 - 306
  • [48] Development of Preclinical Ultrasound Imaging Techniques to Identify and Image Sentinel Lymph Nodes in a Cancerous Animal Model
    Bacou, Marion
    Rajasekaran, Vidya
    Thomson, Adrian
    Sjoestrand, Sandra
    Kaczmarek, Katarzyna
    Ochocka-Fox, Anna Maria
    Gerrard, Adam D.
    Moug, Susan
    Jansson, Tomas
    Mulvana, Helen
    Moran, Carmel M.
    Farrington, Susan M.
    CANCERS, 2022, 14 (03)
  • [49] Breast Cancer in Women: Evaluation of Benign and Malignant Axillary Lymph Nodes with Contrast-Enhanced Ultrasound
    Steppan, I.
    Reimer, D.
    Mueller-Holzner, E.
    Marth, C.
    Aigner, F.
    Frauscher, F.
    Frede, T.
    Zeimet, A. G.
    ULTRASCHALL IN DER MEDIZIN, 2010, 31 (01): : 63 - 67
  • [50] The value of contrast-enhanced ultrasound for sentinel lymph node identification and characterisation in pre-operative breast cancer patients: A prospective study
    Zhao, Jing
    Zhang, Jing
    Zhu, Qing-Li
    Jiang, Yu-Xin
    Sun, Qiang
    Zhou, Yi-Dong
    Wang, Miao-Qian
    Meng, Zhi-Lan
    Mao, Xin-Xin
    EUROPEAN RADIOLOGY, 2018, 28 (04) : 1654 - 1661