A method of reducing background fluctuation in tunable diode laser absorption spectroscopy

被引:13
作者
Yang, Rendi [1 ,2 ]
Dong, Xiaozhou [1 ]
Bi, Yunfeng [1 ]
Lv, Tieliang [1 ]
机构
[1] Shandong Univ Weihai, Sch Mech Elect & Informat Engn, 180 Wenhua West Rd, Weihai, Shandong, Peoples R China
[2] Yantai Univ, Sch Elect & Automot Engn, Yantai, Peoples R China
基金
中国国家自然科学基金;
关键词
Interference fringes; Dual tone modulation; Vibration reflector; Tunable diode laser absorption spectroscopy; WAVELENGTH-MODULATION SPECTROMETRY; INTERFERENCE-FRINGES; REDUCTION; SIGNALS; TDLAS; LIMITS; LEVEL; NOISE;
D O I
10.1016/j.optcom.2017.11.028
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical interference fringe is the main factor that leads to background fluctuation in gas concentration detection based on tunable diode laser absorption spectroscopy. The interference fringes are generated by multiple reflections or scatterings upon optical surfaces in optical path and make the background signal present an approximated sinusoidal oscillation. To reduce the fluctuation of the background, a method that combines dual tone modulation (DTM) with vibration reflector (VR) is proposed in this paper. The combination of DTM and VR can make the unwanted periodic interference fringes to be averaged out and the effectiveness of the method in reducing background fluctuation has been verified by simulation and real experiments in this paper. In the detection system based on the proposed method, the standard deviation ( STD) value of the background signal is decreased to 0.0924 parts per million (ppm), which is reduced by a factor of 16 compared with that of wavelength modulation spectroscopy. The STD value of 0.0924 ppm corresponds to the absorption of 4.328x10(-6) Hz(-1/2) ( with effective optical path length of 4 m and integral time of 0.1 s). Moreover, the proposed method presents a better stable performance in reducing background fluctuation in long time experiments. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:782 / 786
页数:5
相关论文
共 25 条
  • [1] ANALYSIS OF ERRORS CAUSED BY OPTICAL INTERFERENCE EFFECTS IN WAVELENGTH-DIVERSE CO2-LASER LONG-PATH SYSTEMS
    AHLBERG, H
    LUNDQVIST, S
    SHUMATE, MS
    PERSSON, U
    [J]. APPLIED OPTICS, 1985, 24 (22): : 3917 - 3923
  • [2] QUANTUM NOISE-LIMITED FM SPECTROSCOPY WITH A LEAD-SALT DIODE-LASER
    CARLISLE, CB
    COOPER, DE
    PREIER, H
    [J]. APPLIED OPTICS, 1989, 28 (13): : 2567 - 2576
  • [3] HARMONIC DETECTION WITH TUNABLE DIODE-LASERS - 2-TONE MODULATION
    CASSIDY, DT
    REID, J
    [J]. APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1982, 29 (04): : 279 - 285
  • [4] Laser spectroscopic oxygen sensor using diffuse reflector based optical cell and advanced signal processing
    Chen, J.
    Hangauer, A.
    Strzoda, R.
    Amann, M. -C.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2010, 100 (02): : 417 - 425
  • [5] Characterization of 2f-, 4f-, and 6f-background signals in wavelength modulation diode laser absorption spectrometry in graphite furnaces
    Gustafsson, J
    Chekalin, N
    Axner, O
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (01) : 123 - 141
  • [6] Ultra-compact TDLAS humidity measurement cell with advanced signal processing
    Hartmann, A.
    Strzoda, R.
    Schrobenhauser, R.
    Weigel, R.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2014, 115 (02): : 263 - 268
  • [7] Gas cells for tunable diode laser absorption spectroscopy employing optical diffusers. Part 1: single and dual pass cells
    Hodgkinson, J.
    Masiyano, D.
    Tatam, R. P.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2010, 100 (02): : 291 - 302
  • [8] Theoretical description based on Fourier analysis of wavelength-modulation spectrometry in terms of analytical and background signals
    Kluczynski, P
    Axner, O
    [J]. APPLIED OPTICS, 1999, 38 (27) : 5803 - 5815
  • [9] Background signals in wavelength-modulation spectrometry with frequency-doubled diode-laser light.: I.: Theory
    Kluczynski, P
    Lindberg, ÅM
    Axner, O
    [J]. APPLIED OPTICS, 2001, 40 (06) : 783 - 793
  • [10] Compact TDLAS based optical sensor for ppb-level ethane detection by use of a 3.34 μm room-temperature CW interband cascade laser
    Li, Chunguang
    Dong, Lei
    Zheng, Chuantao
    Tittel, Frank K.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2016, 232 : 188 - 194