Photon-Counting Detector CT: Key Points Radiologists Should Know

被引:65
作者
Esquivel, Andrea [1 ]
Ferrero, Andrea [1 ]
Mileto, Achille [1 ]
Baffour, Francis [1 ]
Horst, Kelly [2 ]
Rajiah, Prabhakar Shantha [1 ]
Inoue, Akitoshi [1 ]
Leng, Shuai [1 ]
McCollough, Cynthia [1 ]
Fletcher, Joel G. [1 ,3 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN USA
[2] Mayo Clin, Dept Radiol, Div Pediat Radiol, Rochester, MN USA
[3] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
关键词
Clinical applications; Photon counting X-ray detectors; Spectral tomography; Computed tomography; Diagnostic imaging;
D O I
10.3348/kjr.2022.0377
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Photon-counting detector (PCD) CT is a new CT technology utilizing a direct conversion X-ray detector, where incident X-ray photon energies are directly recorded as electronical signals. The design of the photon-counting detector itself facilitates improvements in spatial resolution (via smaller detector pixel design) and iodine signal (via count weighting) while still permitting multi-energy imaging. PCD-CT can eliminate electronic noise and reduce artifacts due to the use of energy thresholds. Improved dose efficiency is important for low dose CT and pediatric imaging. The ultra-high spatial resolution of PCD-CT design permits lower dose scanning for all body regions and is particularly helpful in identifying important imaging findings in thoracic and musculoskeletal CT. Improved iodine signal may be helpful for low contrast tasks in abdominal imaging. Virtual monoenergetic images and material classification will assist with numerous diagnostic tasks in abdominal, musculoskeletal, and cardiovascular imaging. Dual-source PCD-CT permits multi-energy CT images of the heart and coronary arteries at high temporal resolution. In this special review article, we review the clinical benefits of this technology across a wide variety of radiological subspecialties.
引用
收藏
页码:854 / 865
页数:12
相关论文
共 50 条
[31]   Multi-energy CT imaging for large patients using dual-source photon-counting detector CT [J].
Tao, Shengzhen ;
Marsh, Jeffrey F. ;
Tao, Ashley ;
Michalak, Greg J. ;
Rajendran, Kishore ;
McCollough, Cynthia H. ;
Leng, Shuai .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (17)
[32]   Evaluation of Coronary Plaques and Stents with Conventional and Photon-counting CT: Benefits of High-Resolution Photon-counting CT [J].
Rajagopal, Jayasai R. ;
Farhadi, Faraz ;
Richards, Taylor ;
Nikpanah, Moozhan ;
Sahbaee, Pooyan ;
Shanbhag, Sujata M. ;
Bandettini, W. Patricia ;
Saboury, Babak ;
Malayeri, Ashkan A. ;
Pritchard, William F. ;
Jones, Elizabeth C. ;
Samei, Ehsan ;
Chen, Marcus Y. .
RADIOLOGY-CARDIOTHORACIC IMAGING, 2021, 3 (05)
[33]   Photon-Counting Detector CT Angiography for Endoleak Detection After Endovascular Aortic Repair [J].
Turrion Gomollon, Ana Maria ;
Mergen, Victor ;
Sartoretti, Thomas ;
Polacin, Malgorzata ;
Nakhostin, Dominik ;
Puippe, Gilbert ;
Alkadhi, Hatem ;
Euler, Andre .
INVESTIGATIVE RADIOLOGY, 2023, 58 (11) :816-821
[34]   Effect of temporal resolution on calcium scoring: insights from photon-counting detector CT [J].
Sartoretti, Thomas ;
Mergen, Victor ;
Dzaferi, Amina ;
Allmendinger, Thomas ;
Manka, Robert ;
Alkadhi, Hatem ;
Eberhard, Matthias .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2025, 41 (03) :615-625
[35]   The first mobile photon-counting detector CT: the human images and technical performance study [J].
Park, Su-Jin ;
Park, Junyoung ;
Kim, Doil ;
Lee, Duhgoon ;
Lee, Chang-Lae ;
Bechwati, Ibrahim ;
Wu, Dufan ;
Gupta, Rajiv ;
Jung, Jinwook .
PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (09)
[36]   Comparison of spectral CT imaging methods based a photon-counting detector: Experimental study [J].
Lee, Youngjin ;
Lee, Seungwan ;
Kim, Hee-Joung .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 815 :68-74
[37]   Energy-resolved CT imaging with a photon-counting silicon-strip detector [J].
Persson, Mats ;
Huber, Ben ;
Karlsson, Staffan ;
Liu, Xuejin ;
Chen, Han ;
Xu, Cheng ;
Yveborg, Moa ;
Bornefalk, Hans ;
Danielsson, Mats .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22) :6709-6727
[38]   Quantum Iterative Reconstruction for Abdominal Photon-counting Detector CT Improves Image Quality [J].
Sartoretti, Thomas ;
Landsmann, Anna ;
Nakhostin, Dominik ;
Eberhard, Matthias ;
Roeren, Christian ;
Mergen, Victor ;
Higashigaito, Kai ;
Raupach, Rainer ;
Alkadhi, Hatem ;
Euler, Andre .
RADIOLOGY, 2022, 303 (02)
[39]   Energy-resolved CT imaging with a photon-counting silicon-strip detector [J].
Persson, Mats ;
Huber, Ben ;
Karlsson, Staffan ;
Liu, Xuejin ;
Chen, Han ;
Xu, Cheng ;
Yveborg, Moa ;
Bornefalk, Hans ;
Danielsson, Mats .
MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
[40]   New Contrast Media for K-Edge Imaging With Photon-Counting Detector CT [J].
Jost, Gregor ;
McDermott, Michael ;
Gutjahr, Ralf ;
Nowak, Tristan ;
Schmidt, Bernhard ;
Pietsch, Hubertus .
INVESTIGATIVE RADIOLOGY, 2023, 58 (07) :515-522