Photon-Counting Detector CT: Key Points Radiologists Should Know

被引:112
作者
Esquivel, Andrea [1 ]
Ferrero, Andrea [1 ]
Mileto, Achille [1 ]
Baffour, Francis [1 ]
Horst, Kelly [2 ]
Rajiah, Prabhakar Shantha [1 ]
Inoue, Akitoshi [1 ]
Leng, Shuai [1 ]
McCollough, Cynthia [1 ]
Fletcher, Joel G. [1 ,3 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN USA
[2] Mayo Clin, Dept Radiol, Div Pediat Radiol, Rochester, MN USA
[3] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
关键词
Clinical applications; Photon counting X-ray detectors; Spectral tomography; Computed tomography; Diagnostic imaging;
D O I
10.3348/kjr.2022.0377
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Photon-counting detector (PCD) CT is a new CT technology utilizing a direct conversion X-ray detector, where incident X-ray photon energies are directly recorded as electronical signals. The design of the photon-counting detector itself facilitates improvements in spatial resolution (via smaller detector pixel design) and iodine signal (via count weighting) while still permitting multi-energy imaging. PCD-CT can eliminate electronic noise and reduce artifacts due to the use of energy thresholds. Improved dose efficiency is important for low dose CT and pediatric imaging. The ultra-high spatial resolution of PCD-CT design permits lower dose scanning for all body regions and is particularly helpful in identifying important imaging findings in thoracic and musculoskeletal CT. Improved iodine signal may be helpful for low contrast tasks in abdominal imaging. Virtual monoenergetic images and material classification will assist with numerous diagnostic tasks in abdominal, musculoskeletal, and cardiovascular imaging. Dual-source PCD-CT permits multi-energy CT images of the heart and coronary arteries at high temporal resolution. In this special review article, we review the clinical benefits of this technology across a wide variety of radiological subspecialties.
引用
收藏
页码:854 / 865
页数:12
相关论文
共 28 条
[1]   Photon-Counting Detector CT-Based Vascular Calcium Removal Algorithm Assessment Using a Cardiac Motion Phantom [J].
Allmendinger, Thomas ;
Nowak, Tristan ;
Flohr, Thomas ;
Klotz, Ernst ;
Hagenauer, Junia ;
Alkadhi, Hatem ;
Schmidt, Bernhard .
INVESTIGATIVE RADIOLOGY, 2022, 57 (06) :399-405
[2]   Ultra-high-resolution imaging of the shoulder and pelvis using photon-counting-detector CT: a feasibility study in patients [J].
Baffour, Francis, I ;
Rajendran, Kishore ;
Glazebrook, Katrina N. ;
Thorne, Jamison E. ;
Larson, Nicholas B. ;
Leng, Shuai ;
McCollough, Cynthia H. ;
Fletcher, Joel G. .
EUROPEAN RADIOLOGY, 2022, 32 (10) :7079-7086
[3]   High-Resolution Chest Computed Tomography Imaging of the Lungs Impact of 1024 Matrix Reconstruction and Photon-Counting Detector Computed Tomography [J].
Bartlett, David J. ;
Koo, Chi Wan ;
Bartholmai, Brian J. ;
Rajendran, Kishore ;
Weaver, Jayse M. ;
Halaweish, Ahmed E. ;
Leng, Shuai ;
McCollough, Cynthia H. ;
Fletcher, Joel G. .
INVESTIGATIVE RADIOLOGY, 2019, 54 (03) :129-137
[4]   A New Frontier in Temporal Bone Imaging: Photon-Counting Detector CT Demonstrates Superior Visualization of Critical Anatomic Structures at Reduced Radiation Dose [J].
Benson, J. C. ;
Rajendran, K. ;
Lane, J. I. ;
Diehn, F. E. ;
Weber, N. M. ;
Thorne, J. E. ;
Larson, N. B. ;
Fletcher, J. G. ;
McCollough, C. H. ;
Leng, S. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2022, :579-584
[5]   Human Imaging With Photon Counting-Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies [J].
Gutjahr, Ralf ;
Halaweish, Ahmed F. ;
Yu, Zhicong ;
Leng, Shuai ;
Yu, Lifeng ;
Li, Zhoubo ;
Jorgensen, Steven M. ;
Ritman, Erik L. ;
Kappler, Steffen ;
McCollough, Cynthia H. .
INVESTIGATIVE RADIOLOGY, 2016, 51 (07) :421-429
[6]  
Hong G, 2021, 107 SCI ASSEMBLY ANN
[7]  
Hsieh SS, 2021, IEEE T RADIAT PLASMA, V5, P441, DOI [10.1109/TRPMS.2020.3020212, 10.1109/trpms.2020.3020212]
[8]   Estimating the Clinical Impact of Photon-Counting-Detector CT in Diagnosing Usual Interstitial Pneumonia [J].
Inoue, Akitoshi ;
Johnson, Tucker F. ;
White, Darin ;
Cox, Christian W. ;
Hartman, Thomas E. ;
Thorne, Jamison E. ;
Shanblatt, Elisabeth R. ;
Johnson, Matthew P. ;
Carter, Rickey E. ;
Lee, Yong S. ;
Rajendran, Kishore ;
Leng, Shuai ;
McCollough, Cynthia H. ;
Fletcher, Joel G. .
INVESTIGATIVE RADIOLOGY, 2022, 57 (11) :734-741
[9]   Image quality in abdominal CT using an iodine contrast reduction algorithm employing patient size and weight and low kV CT technique [J].
Iyer, Veena R. ;
Ehman, Eric C. ;
Khandelwal, Ashish ;
LWells, Michael ;
Lee, Yong S. ;
Weber, Nikkole M. ;
Johnson, Matthew P. ;
Yu, Lifeng ;
McCollough, Cynthia H. ;
Fletcher, Joel G. .
ACTA RADIOLOGICA, 2020, 61 (09) :1186-1195
[10]   Update on Cardiovascular Applications of Multienergy CT [J].
Kalisz, Kevin ;
Halliburton, Sandra ;
Abbara, Suhny ;
Leipsic, Jonathon A. ;
Albrecht, Moritz H. ;
Schoepf, U. Joseph ;
Rajiah, Prabhakar .
RADIOGRAPHICS, 2017, 37 (07) :1955-1974