Effect of wavelength and beam width on penetration in light-tissue interaction using computational methods

被引:728
作者
Ash, Caerwyn [1 ]
Dubec, Michael [2 ]
Donne, Kelvin [1 ]
Bashford, Tim [1 ]
机构
[1] Univ Wales Trinity St David, Sch Appl Comp, Swansea SA1 6ED, W Glam, Wales
[2] Christie NHS Fdn Trust, 550 Wilmslow Rd, Manchester M20 4BX, Lancs, England
关键词
IPL; Laser; Monte Carlo; Penetration; HUMAN-SKIN; OPTICAL-PROPERTIES;
D O I
10.1007/s10103-017-2317-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Penetration depth of ultraviolet, visible light and infrared radiation in biological tissue has not previously been adequately measured. Risk assessment of typical intense pulsed light and laser intensities, spectral characteristics and the subsequent chemical, physiological and psychological effects of such outputs on vital organs as consequence of inappropriate output use are examined. This technical note focuses on wavelength, illumination geometry and skin tone and their effect on the energy density (fluence) distribution within tissue. Monte Carlo modelling is one of the most widely used stochastic methods for the modelling of light transport in turbid biological media such as human skin. Using custom Monte Carlo simulation software of a multi-layered skin model, fluence distributions are produced for various non-ionising radiation combinations. Fluence distributions were analysed using Matlab mathematical software. Penetration depth increases with increasing wavelength with a maximum penetration depth of 5378 mu m calculated. The calculations show that a 10-mm beam width produces a fluence level at target depths of 1-3 mm equal to 73-88% (depending on depth) of the fluence level at the same depths produced by an infinitely wide beam of equal incident fluence. Meaning little additional penetration is achieved with larger spot sizes. Fluence distribution within tissue and thus the treatment efficacy depends upon the illumination geometry and wavelength. To optimise therapeutic techniques, light-tissue interactions must be thoroughly understood and can be greatly supported by the use of mathematical modelling techniques.
引用
收藏
页码:1909 / 1918
页数:10
相关论文
共 31 条
[1]   THE OPTICS OF HUMAN-SKIN [J].
ANDERSON, RR ;
PARRISH, JA .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1981, 77 (01) :13-19
[2]  
Ash C, 2009, THESIS
[3]   Mathematical modeling of the optimum pulse structure for safe and effective photo epilation using broadband pulsed light [J].
Ash, Caerwyn ;
Donne, Kelvin ;
Daniel, Gwenaelle ;
Town, Godfrey ;
Clement, Marc ;
Valentine, Ronan .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (05) :290-299
[4]  
Baranoski GVG, 2010, LIGHT & SKIN INTERACTIONS: SIMULATIONS FOR COMPUTER GRAPHICS APPLICATIONS, P1, DOI 10.1016/B978-0-12-375093-8.00001-0
[5]  
Barnes C., 2011, THESIS
[6]   OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW [J].
Bashkatov, Alexey N. ;
Genina, Elina A. ;
Tuchin, Valery V. .
JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2011, 4 (01) :9-38
[8]   The protective role of melanin against UV damage in human skin [J].
Brenner, Michaela ;
Hearing, Vincent J. .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2008, 84 (03) :539-549
[9]   Immuno gold nanocages with tailored optical properties for targeted photothermal destruction of cancer cells [J].
Chen, Jingyi ;
Wang, Danling ;
Xi, Jiefeng ;
Au, Leslie ;
Siekkinen, Andy ;
Warsen, Addie ;
Li, Zhi-Yuan ;
Zhang, Hui ;
Xia, Younan ;
Li, Xingde .
NANO LETTERS, 2007, 7 (05) :1318-1322
[10]  
Clement Marc, 2005, J Cosmet Laser Ther, V7, P177, DOI 10.1080/14764170500344575