Application of polymer dose gels for millimeter scale target/tumor pre-treatment immitation using gamma knife facility

被引:3
作者
Jaselske, Evelina [1 ,2 ]
Adliene, Diana [1 ]
Rudzianskas, Viktoras [1 ,2 ]
Korobeinikova, Erika [1 ,2 ]
Radziunas, Andrius [3 ]
机构
[1] Kaunas Univ Technol, Phys Dept, Kaunas, Lithuania
[2] Lithuanian Univ Hlth Sci, Oncol Inst, Kaunas, Lithuania
[3] Lithuanian Univ Hlth Sci, Neurosurg Dept, Med Acad, Kaunas, Lithuania
关键词
Gel dosimeters; 3D dosimetry phantoms; Millimetre scale target; Gamma knife treatment; DOSIMETRY; OPTIMIZATION;
D O I
10.1016/j.nimb.2020.03.009
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Polymer gels are widely used for absorbed dose verification in radiotherapy, providing information about 3D dose distribution in the irradiated volume as well as serving as a simulation phantom, for the observation of radiation induced structural changes, related to gel's polymerization upon irradiation. Due to high spatial resolution and unable sensitivity through gel's composition, dosimeter gels is a powerful and precise tool for verification of individual treatment plans especially when high treatment doses are prescribed. The aim of this work was to modify and characterize gel dosimeters that are capable of millimetre scale target/tumour imitation and high dose assessment in small irradiated volume, for their further applications in clinical dosimetry and verification of millimetre scale target treatment procedures using Gamma knife unit.
引用
收藏
页码:56 / 60
页数:5
相关论文
共 20 条
  • [1] Abtahi SM, 2014, INT J RADIAT RES, V12, P139
  • [2] Abtahi SM, 2008, IRAN J RADIAT RES, V6, P151
  • [3] Application of optical methods for dose evaluation in normoxic polyacrylamide gels irradiated at two different geometries
    Adliene, D.
    Jakstas, K.
    Vaiciunaite, N.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 741 : 88 - 94
  • [4] [Anonymous], [No title captured]
  • [5] [Anonymous], 2014, IJMP
  • [6] Antoniou Panagiotis E., 2008, Recent Patents on Biomedical Engineering, V1, P203, DOI 10.2174/1874764710801030203
  • [7] Polymer gel dosimetry
    Baldock, C.
    De Deene, Y.
    Doran, S.
    Ibbott, G.
    Jirasek, A.
    Lepage, M.
    McAuley, K. B.
    Oldham, M.
    Schreiner, L. J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05) : R1 - R63
  • [8] Dose evaluation of an NIPAM polymer gel dosimeter using gamma index
    Chang, Yuan-Jen
    Lin, Jing-Quan
    Hsieh, Bor-Tsung
    Yao, Chun-Hsu
    Chen, Chin-Hsing
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 180 - 187
  • [9] How to scan polymer gels with MRI?
    De Deene, Y.
    [J]. 7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [10] Optimization of multiple spin-echo sequences for 3D polymer gel dosimetry
    De Deene, Y.
    Baldock, C.
    [J]. 2002, Institute of Physics Publishing (47)