Determination of antimony in water samples by hydride generation coupled with atmospheric pressure glow discharge atomic emission spectrometry

被引:31
|
作者
Zhu, Zhenli [1 ]
Yang, Chun [1 ]
Yu, Peiwen [1 ]
Zheng, Hongtao [2 ]
Liu, Zhifu [1 ]
Xing, Zhi [3 ]
Hu, Shenghong [1 ]
机构
[1] China Univ Geosci, Sch Earth Sci, State Key Lab Biogeol & Environm Geol, Wuhan 430074, Hubei, Peoples R China
[2] China Univ Geosci, Fac Mat Sci & Chem, Wuhan 430074, Hubei, Peoples R China
[3] Tsinghua Univ, Dept Chem, Beijing Key Lab Microanalyt Methods & Instrumenta, Beijing 10084, Peoples R China
基金
中国国家自然科学基金;
关键词
DIELECTRIC BARRIER DISCHARGE; FLOWING LIQUID CATHODE; EXCITATION SOURCE; VAPOR GENERATION; MICROPLASMA; MERCURY; PRECONCENTRATION; TRACE; SB; CHROMATOGRAPHY;
D O I
10.1039/c8ja00271a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A low power (similar to 10 W), miniaturized atmospheric pressure glow discharge (APGD) source sustained between a tungsten cathode and a titanium tube anode was coupled with a hydride generation (HG) system for sensitive determination of antimony in water samples with atomic emission spectrometry (AES). Sb ions were converted into volatile hydrides through the reaction with KBH4 firstly and then were introduced into the APGD source for excitation and detected using a compact CCD (charge-coupled device) microspectrometer. A univariate approach was used to achieve optimized conditions and derive analytical figures of merit. Under optimal conditions, the limits of detection and quantification for Sb were 0.14 and 0.5 mg L-1, respectively. Moreover, the HG-APGD-AES system offered good repeatability (relative standard deviation <1.5%). The calibration curve was linear in the range between 0.5 and 100 mg L-1, with a correlation coefficient of R-2 = 0.9996. The proposed method was successfully applied to the determination of certified reference materials (GSB 07-1376-2001, GBW07305a, GBW07307a and GBW073066) and some groundwater samples. Recoveries of Sb added to these water samples were within 90.9-100.7%, proving the good accuracy of the HG-APGD-AES method.
引用
收藏
页码:331 / 337
页数:7
相关论文
共 50 条
  • [21] Speciation of Antimony(III) and Antimony(V) in Bottled Water by Hydride Generation-Inductively Coupled Plasma Optical Emission Spectrometry
    Goncalves dos Santos, Vanessa Cristina
    Grassi, Marco Tadeu
    Abate, Gilberto
    ANALYTICAL LETTERS, 2015, 48 (18) : 2921 - 2935
  • [22] The determination of antimony and arsenic concentrations in fly ash by hydride generation inductively coupled plasma optical emission spectrometry
    Ilander, Aki
    Vaisanen, Ari
    ANALYTICA CHIMICA ACTA, 2011, 689 (02) : 178 - 183
  • [23] Reduction of spectral interferences in atmospheric pressure glow discharge optical emission spectrometry
    Greda, Krzysztof
    Swiderski, Krzysztof
    Jamroz, Piotr
    Pohl, Pawel
    MICROCHEMICAL JOURNAL, 2017, 130 : 7 - 13
  • [24] Simultaneously determination of multi metal elements in water samples by liquid cathode glow discharge-atomic emission spectrometry
    Yu, Jie
    Yang, Shuxiu
    Sun, Duixiong
    Lu, Quanfang
    Zheng, Jidong
    Zhang, Xiaomei
    Wang, Xing
    MICROCHEMICAL JOURNAL, 2016, 128 : 325 - 330
  • [25] Performance Evaluation of Atmospheric Pressure Glow Discharge-Optical Emission Spectrometry for the Determination of Sodium, Lithium, Calcium and Magnesium Using Membrane Desolvation
    Dong, Junhang
    Yang, Chun
    He, Dong
    Zheng, Hongtao
    Hu, Shenghong
    Zhu, Zhenli
    ATOMIC SPECTROSCOPY, 2020, 41 (02) : 57 - 63
  • [26] Trace determination of antimony by hydride generation atomic absorption spectrometry with analyte preconcentration/atomization in a dielectric barrier discharge atomizer
    Zurynkova, Pavla
    Dedina, Jiri
    Kratzer, Jan
    ANALYTICA CHIMICA ACTA, 2018, 1010 : 11 - 19
  • [27] Ultrasensitive determination of mercury by atmospheric pressure glow discharge optical emission spectroscopy coupled with solution cathode glow discharge microplasma
    Chen, Huixiu
    Wang, Zheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (10) : 2185 - 2191
  • [28] Highly Sensitive Determination of Selenium, Arsenic and Mercury in Seawater by Hydride Generation Coupled with Solution Cathode Glow Discharge Optical Emission Spectrometry
    Zhao Ming-yue
    Cheng Jun-qi
    Yang Bing-cheng
    Wang Zheng
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39 (05) : 1359 - 1365
  • [29] Direct determination of cadmium in rice by solid sampling electrothermal vaporization atmospheric pressure glow discharge atomic emission spectrometry using a tungsten coil trap
    Deng, Qisi
    Yang, Chun
    Zheng, Hongtao
    Liu, Jixin
    Mao, Xuefei
    Hu, Shenghong
    Zhu, Zhenli
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (09) : 1786 - 1793
  • [30] Highly sensitive determination of cadmium and lead in whole blood by electrothermal vaporization-atmospheric pressure glow discharge atomic emission spectrometry
    Qian, Ling
    Lei, Zhendong
    Peng, Xiaoxu
    Yang, Guangzhi
    Wang, Zheng
    ANALYTICA CHIMICA ACTA, 2021, 1162