A comparison of conventional spin-echo and fast spin-echo in the detection of multiple sclerosis

被引:12
|
作者
Patola, WB [1 ]
Coulter, BA [1 ]
Chipperfield, PM [1 ]
Lingawi, SS [1 ]
机构
[1] Univ British Columbia, St Pauls Hosp, Dept Radiol, Vancouver, BC V5Z 1M9, Canada
关键词
multiple sclerosis; spin-echo imaging; fast spin-echo imaging; magnetic resonance imaging; brain;
D O I
10.1002/jmri.1093
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fast spin-echo (PSE) pulse sequences enable T2-weighted imaging in a fraction of the time required for T2-weighted conventional spin-echo (CSE) imaging. Due to concerns that the altered contrast characteristics of FSE may interfere with the visualization of multiple sclerosis (MS) lesions, the sensitivity of T2-weighted FSE sequences was compared to comparably weighted CSE sequences in the imaging of the brain in 100 patients with clinically suspected MS. The proton-density FSE sequence revealed more MS lesions than Its CSE counterpart, while the T2-weighted CSE sequences were found to be more sensitive than the T2-weighted FSE sequence. Contrast-to-noise ratios and signal-to-noise ratios compared favorably between sequences. Overall, there was little difference in the specificity between FSE and CSE in the diagnosis of MS. The higher sensitivity and the reduction in time attainable through the use of FSE warrants its replacement of CSE when imaging the brain In patients with clinically suspected MS. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:657 / 667
页数:11
相关论文
共 50 条
  • [31] Enhancement efficacy of magnetic starch microspheres (MSM) in conventional spin-echo and turbo spin-echo sequences at 0.5 T and 1.5 T
    Kreft, B
    Block, W
    Muhlhauser, J
    Traber, F
    Oksendal, A
    Schild, H
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (02): : 378 - 383
  • [32] Multiple Sclerosis: Comparison of the Conventional Spin-Echo T2-Weighted and Flair Techniques Through Image Processing
    Simao, Ricardo Silva
    de Azevedo Alves, Rafaela Ferreira
    Matos da Silva Boschi, Silvia Regina
    Scardovelli, Terigi Augusto
    Martini Rodrigues, Silvia Cristina
    Bianchi, Cesario
    da Silva, Alessandro Pereira
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (03) : 425 - 430
  • [33] Spin-echo MRI of chronic intracerebral haematomas
    A. Brander
    M. Kotila
    O. Salonen
    Neuroradiology, 1997, 39 : 25 - 29
  • [34] Spin-echo MRI of chronic intracerebral haematomas
    Brander, A
    Salonen, O
    Kotila, M
    NEURORADIOLOGY, 1997, 39 (01) : 25 - 29
  • [35] The effect of cross-talk on MRI lesion numbers and volumes in multiple sclerosis using conventional and turbo spin-echo
    Filippi, M
    Yousry, TA
    Rocca, MA
    Pereira, C
    Alkadhi, H
    Comi, G
    MULTIPLE SCLEROSIS, 1998, 4 (06): : 471 - 474
  • [36] Quantitative comparison of conventional spin echo and fast spin echo during brain myelination
    Shaw, DWW
    Weinberger, E
    Astley, SJ
    Tsuruda, JS
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (06) : 867 - 871
  • [37] The influence of stimulated echoes on contrast in fast spin-echo imaging
    Williams, CFM
    Redpath, TW
    Smith, FW
    MAGNETIC RESONANCE IMAGING, 1996, 14 (04) : 419 - 428
  • [38] FAST SPIN-ECHO INVERSION-RECOVERY IMAGING VERSUS FAST T2-WEIGHTED SPIN-ECHO IMAGING IN BONE-MARROW ABNORMALITIES
    HILFIKER, P
    ZANETTI, M
    DEBATIN, JF
    MCKINNON, G
    HODLER, J
    INVESTIGATIVE RADIOLOGY, 1995, 30 (02) : 110 - 114
  • [39] Comparison of MERGE and Axial T2-Weighted Fast Spin-Echo Sequences for Detection of Multiple Sclerosis Lesions in the Cervical Spinal Cord
    Martin, Nancy
    Malfair, David
    Zhao, Yinshan
    Li, David
    Traboulsee, Anthony
    Lang, Donna
    Vertinsky, Alexandra Talia
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (01) : 157 - 162
  • [40] BOLD background gradient contributions in diffusion-weighted fMRI-comparison of spin-echo and twice-refocused spin-echo sequences
    Pampel, Andre
    Jochimsen, Thies H.
    Moeller, Harald E.
    NMR IN BIOMEDICINE, 2010, 23 (06) : 610 - 618