A comparison of conventional spin-echo and fast spin-echo in the detection of multiple sclerosis

被引:12
|
作者
Patola, WB [1 ]
Coulter, BA [1 ]
Chipperfield, PM [1 ]
Lingawi, SS [1 ]
机构
[1] Univ British Columbia, St Pauls Hosp, Dept Radiol, Vancouver, BC V5Z 1M9, Canada
关键词
multiple sclerosis; spin-echo imaging; fast spin-echo imaging; magnetic resonance imaging; brain;
D O I
10.1002/jmri.1093
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fast spin-echo (PSE) pulse sequences enable T2-weighted imaging in a fraction of the time required for T2-weighted conventional spin-echo (CSE) imaging. Due to concerns that the altered contrast characteristics of FSE may interfere with the visualization of multiple sclerosis (MS) lesions, the sensitivity of T2-weighted FSE sequences was compared to comparably weighted CSE sequences in the imaging of the brain in 100 patients with clinically suspected MS. The proton-density FSE sequence revealed more MS lesions than Its CSE counterpart, while the T2-weighted CSE sequences were found to be more sensitive than the T2-weighted FSE sequence. Contrast-to-noise ratios and signal-to-noise ratios compared favorably between sequences. Overall, there was little difference in the specificity between FSE and CSE in the diagnosis of MS. The higher sensitivity and the reduction in time attainable through the use of FSE warrants its replacement of CSE when imaging the brain In patients with clinically suspected MS. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:657 / 667
页数:11
相关论文
共 50 条
  • [21] Comparison of a conventional cardiac-triggered dual spin-echo and a fast STIR sequence in detection of spinal cord lesions in multiple sclerosis
    Bot, JCJ
    Barkhof, F
    Nijeholt, GJLA
    Bergers, E
    Polman, CH
    Adèr, HJ
    Castelijns, JA
    EUROPEAN RADIOLOGY, 2000, 10 (05) : 753 - 758
  • [22] Multi-shot echo-planar Flair imaging of brain tumors: comparison of spin-echo T1-weighted, fast spin-echo T2-weighted, and fast spin-echo Flair imaging
    Tomura, N
    Kato, K
    Takahashi, S
    Sashi, R
    Izumi, J
    Narita, K
    Watarai, J
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (02) : 65 - 72
  • [23] A comparison of conventional and fast spin-echo sequences for the measurement of lesion load in multiple sclerosis using a semi-automated contour technique
    Rovaris, M
    GawneCain, ML
    Wang, L
    Miller, DH
    NEURORADIOLOGY, 1997, 39 (03) : 161 - 165
  • [24] T2-weighted MRI of rectosigmoid carcinoma: Comparison of respiratory-triggered fast spin-echo, breathhold fast-recovery fast spin-echo, and breathhold single-shot fast spin-echo sequences
    Yamashita, Shuhei
    Masui, Takayuki
    Katayama, Motoyuki
    Sato, Kimihiko
    Yoshizawa, Nobuko
    Seo, Hidekazu
    Sakahara, Harumi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (03) : 511 - 516
  • [25] FAST SPIN-ECHO MR IN HIPPOCAMPAL SCLEROSIS - CORRELATION WITH PATHOLOGY AND SURGERY
    KIM, JH
    TIEN, RD
    FELSBERG, GJ
    OSUMI, AK
    LEE, N
    FRIEDMAN, AH
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1995, 16 (04) : 627 - 636
  • [26] DIAGNOSIS OF MESIAL TEMPORAL SCLEROSIS WITH CONVENTIONAL VERSUS FAST SPIN-ECHO MR-IMAGING
    JACK, CR
    KRECKE, KN
    LUETMER, PH
    CASCINO, GD
    SHARBROUGH, FW
    OBRIEN, PC
    PARISI, JE
    RADIOLOGY, 1994, 192 (01) : 123 - 127
  • [27] A comparison of conventional and fast spin-echo sequences for the measurement of lesion load in multiple sclerosis using a semi-automated contour technique
    M. Rovaris
    M. L. Gawne-Cain
    L. Wang
    D. H. Miller
    Neuroradiology, 1997, 39 : 161 - 165
  • [28] Quantitative assessment of MRI lesion load in multiple sclerosis - A comparison of conventional spin-echo with fast fluid-attenuated inversion recovery
    Filippi, M
    Yousry, T
    Baratti, C
    Horsfield, MA
    Mammi, S
    Becker, C
    Voltz, R
    Spuler, S
    Campi, A
    Reiser, MF
    Comi, G
    BRAIN, 1996, 119 : 1349 - 1355
  • [29] Isotropic three-dimensional fast spin-echo Cube magnetic resonance dacryocystography: comparison with the three-dimensional fast-recovery fast spin-echo technique
    Zhang, Jing
    Chen, Lang
    Wang, Qiu-Xia
    Liu, Rong
    Zhu, Wen-Zhen
    Luo, Xin
    Peng, Li
    Xiong, Wei
    NEURORADIOLOGY, 2015, 57 (04) : 357 - 365
  • [30] Isotropic three-dimensional fast spin-echo Cube magnetic resonance dacryocystography: comparison with the three-dimensional fast-recovery fast spin-echo technique
    Jing Zhang
    Lang Chen
    Qiu-Xia Wang
    Rong Liu
    Wen-Zhen Zhu
    Xin Luo
    Li Peng
    Wei Xiong
    Neuroradiology, 2015, 57 : 357 - 365