A comparison of conventional spin-echo and fast spin-echo in the detection of multiple sclerosis

被引:12
作者
Patola, WB [1 ]
Coulter, BA [1 ]
Chipperfield, PM [1 ]
Lingawi, SS [1 ]
机构
[1] Univ British Columbia, St Pauls Hosp, Dept Radiol, Vancouver, BC V5Z 1M9, Canada
关键词
multiple sclerosis; spin-echo imaging; fast spin-echo imaging; magnetic resonance imaging; brain;
D O I
10.1002/jmri.1093
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fast spin-echo (PSE) pulse sequences enable T2-weighted imaging in a fraction of the time required for T2-weighted conventional spin-echo (CSE) imaging. Due to concerns that the altered contrast characteristics of FSE may interfere with the visualization of multiple sclerosis (MS) lesions, the sensitivity of T2-weighted FSE sequences was compared to comparably weighted CSE sequences in the imaging of the brain in 100 patients with clinically suspected MS. The proton-density FSE sequence revealed more MS lesions than Its CSE counterpart, while the T2-weighted CSE sequences were found to be more sensitive than the T2-weighted FSE sequence. Contrast-to-noise ratios and signal-to-noise ratios compared favorably between sequences. Overall, there was little difference in the specificity between FSE and CSE in the diagnosis of MS. The higher sensitivity and the reduction in time attainable through the use of FSE warrants its replacement of CSE when imaging the brain In patients with clinically suspected MS. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:657 / 667
页数:11
相关论文
共 30 条
[21]   MRI IN THE DIAGNOSIS OF MS - A PROSPECTIVE-STUDY WITH COMPARISON OF CLINICAL-EVALUATION, EVOKED-POTENTIALS, OLIGOCLONAL BANDING, AND CT [J].
PATY, DW ;
OGER, JJF ;
KASTRUKOFF, LF ;
HASHIMOTO, SA ;
HOOGE, JP ;
EISEN, AA ;
EISEN, KA ;
PURVES, SJ ;
LOW, MD ;
BRANDEJS, V ;
ROBERTSON, WD ;
LI, DKB .
NEUROLOGY, 1988, 38 (02) :180-185
[22]   Lesion load quantification on fast-flair, rapid acquisition relaxation-enhanced, and gradient spin echo brain MRI scans from multiple sclerosis patients [J].
Rovaris, M ;
Rocca, MA ;
Yousry, I ;
Yousry, TA ;
Colombo, B ;
Comi, G ;
Filippi, M .
MAGNETIC RESONANCE IMAGING, 1999, 17 (08) :1105-1110
[23]  
Rovaris M, 1999, AM J NEURORADIOL, V20, P813
[24]   A comparison of conventional and fast spin-echo sequences for the measurement of lesion load in multiple sclerosis using a semi-automated contour technique [J].
Rovaris, M ;
GawneCain, ML ;
Wang, L ;
Miller, DH .
NEURORADIOLOGY, 1997, 39 (03) :161-165
[25]   Sensitivity and reproducibility of fast-FLAIR, FSE, and TGSE sequences for the MRI assessment of brain lesion load in multiple sclerosis: A preliminary study [J].
Rovaris, M ;
Fesl, G ;
Yousry, T ;
Voltz, R ;
Calori, G ;
Filippi, M .
JOURNAL OF NEUROIMAGING, 1997, 7 (02) :98-102
[26]   PATTERNS OF DISEASE-ACTIVITY IN MULTIPLE-SCLEROSIS - CLINICAL AND MAGNETIC-RESONANCE-IMAGING STUDY [J].
THOMPSON, AJ ;
KERMODE, AG ;
MACMANUS, DG ;
KENDALL, BE ;
KINGSLEY, DPE ;
MOSELEY, IF ;
MCDONALD, WI .
BRITISH MEDICAL JOURNAL, 1990, 300 (6725) :631-634
[27]   A COMPARISON BETWEEN FAST AND CONVENTIONAL SPIN-ECHO IN THE DETECTION OF MULTIPLE-SCLEROSIS LESIONS [J].
THORPE, JW ;
HALPIN, SF ;
MACMANUS, DG ;
BARKER, GJ ;
KENDALL, BE ;
MILLER, DH .
NEURORADIOLOGY, 1994, 36 (05) :388-392
[28]   Diffusion-weighted MR imaging in multiple sclerosis: comparison with contrast-enhanced study [J].
Tsuchiya, K ;
Hachiya, J ;
Maehara, T .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 31 (03) :165-169
[29]   Three-dimensional fast fluid attenuated inversion recovery (3D fast FLAIR): a new MRI sequence which increases the detectable cerebral lesion load in multiple sclerosis [J].
Tubridy, N ;
Barker, GJ ;
Macmanus, DG ;
Moseley, IF ;
Miller, DH .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (848) :840-845
[30]   The sensitivity of thin-slice fast spin echo, fast FLAIR and gadolinium-enhanced T1-weighted MRI sequences in detecting new lesion activity in multiple sclerosis [J].
Tubridy, N ;
Molyneux, PD ;
Moseley, IF ;
Miller, DH .
JOURNAL OF NEUROLOGY, 1999, 246 (12) :1181-1185