COMPARISON OF PEDIATRIC LENS DOSE MEASUREMENTS BETWEEN AXIAL SCAN MODE WITHOUT ACTIVE COLLIMATOR AND HELICAL SCAN MODE WITH ACTIVE COLLIMATOR BY USING A 64 DETECTOR-ROW COMPUTED TOMOGRAPHY SCANNER

被引:0
作者
Masuda, Takanori [1 ]
Funama, Yoshinori [2 ]
Nakaura, Takeshi [3 ]
Sato, Tomoyasu [4 ]
Urayama, Kotaro [5 ]
Kiguchi, Masao [6 ]
Oku, Takayuki [7 ]
Arao, Shinichi [1 ]
Ono, Atsushi [1 ]
Hiratsuka, Junichi [1 ]
Awai, Kazuo [6 ]
机构
[1] Kawasaki Univ Med Welf, Dept Radiol Technol, Fac Hlth Sci & Technol, 288 Matsushima, Kurashiki, Okayama 7010193, Japan
[2] Kumamoto Univ, Fac Life Sci, Dept Med Phys, 1-1-1 Honjo, Kumamoto 8608556, Japan
[3] Kumamoto Univ, Dept Diagnost Radiol, Grad Sch Med Sci, 1-1-1 Honjo, Kumamoto 8608556, Japan
[4] Tsuchiya Gen Hosp, Dept Diagnost Radiol, Naka Ku, Nakajima Cho 3-30, Hiroshima 7308655, Japan
[5] Tsuchiya Gen Hosp, Dept Pediat Cardiol, Naka Ku, Nakajima Cho 3-30, Hiroshima 7308655, Japan
[6] Hiroshima Univ, Dept Diagnost Radiol, Grad Sch Biomed Sci, Minami Ku, Kasumi 1-2-3, Hiroshima 7348551, Japan
[7] Tsuchiya Gen Hosp, Dept Radiol Technologist, Naka Ku, Nakajima Cho 3-30, Hiroshima 7308655, Japan
关键词
RADIATION; CT;
D O I
10.1093/rpd/ncac196
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To investigate the pediatric eye lens entrance surface dose for both axial scan modes without an active collimator and helical scan modes with an active collimator on 64 detector-row computed tomography (CT) scanner. We used three pediatric anthropomorphic phantoms with axial and helical scan modes from the superior orbitomeatal line to the crown of the head. We compared the measured dose values of the real-time skin dosemeter at the surfaces of the lens and the image noise at different scan modes. The median measured dose values for the lens of newborn, 1-year-old and the 5-year-old phantom were 31.3, 0.97 and 0.65 mGy, respectively, in the axial scan mode and 0.89, 1.21 and 0.71 mGy, respectively, in the helical scan mode. Compared with helical scans with an active collimators, axial scans can reduce the lens dose by similar to 10% during head CT on 64 detector-row CT scanner without deterioration of image noise.
引用
收藏
页码:1522 / 1527
页数:6
相关论文
共 21 条
  • [1] Radiation Cataractogenesis: A Review of Recent Studies
    Ainsbury, E. A.
    Bouffler, S. D.
    Doerr, W.
    Graw, J.
    Muirhead, C. R.
    Edwards, A. A.
    Cooper, J.
    [J]. RADIATION RESEARCH, 2009, 172 (01) : 1 - 9
  • [2] The lens is more sensitive to radiation than we had believed
    Brown, NP
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1997, 81 (04) : 257 - 257
  • [3] Effective doses in standard protocols for multi-slice CT scanning
    Cohnen, M
    Poll, LW
    Puettmann, C
    Ewen, K
    Saleh, A
    Mödder, U
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (05) : 1148 - 1153
  • [4] An evaluation of organ dose modulation on a GE optima CT660-computed tomography scanner
    Dixon, Matthew T.
    Loader, Robert J.
    Stevens, Gregory C.
    Rowles, Nick P.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 380 - 391
  • [5] System performance of multislice spiral computed tomography
    Fuchs, TOJ
    Kachelriess, M
    Kalender, WA
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2000, 19 (05): : 63 - 70
  • [6] Advances in Computed Tomography Imaging Technology
    Ginat, Daniel Thomas
    Gupta, Rajiv
    [J]. ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, VOL 16, 2014, 16 : 431 - 453
  • [7] USE OF VACUUM MATTRESSES CAN REDUCE THE ABSORBED DOSE DURING PEDIATRIC CT
    Masuda, Takanori
    Funama, Yoshinori
    Nakaura, Takeshi
    Sato, Tomoyasu
    Tahara, Masahiro
    Takei, Yasutaka
    Yamashita, Yukari
    Oku, Takayuki
    Masuda, Shouko
    Kiguchi, Masao
    Awai, Kazuo
    [J]. RADIATION PROTECTION DOSIMETRY, 2021, 194 (04) : 201 - 207
  • [8] Pediatric organ dose measurements in axial and helical multislice CT
    McDermott, Alanna
    White, R. Allen
    Mc-Nitt-Gray, Mike
    Angel, Erin
    Cody, Dianna
    [J]. MEDICAL PHYSICS, 2009, 36 (05) : 1494 - 1499
  • [9] Lens Dose Reduction by Patient Posture Modification During Neck CT
    Mosher, Elizabeth G.
    Butman, John A.
    Folio, Les R.
    Biassou, Nadia M.
    Lee, Choonsik
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (05) : 1111 - 1117
  • [10] Novel Dosimeter Using a Nontoxic Phosphor for Real-Time Monitoring of Patient Radiation Dose in Interventional Radiology
    Nakamura, Masaaki
    Chida, Koichi
    Zuguchi, Masayuki
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (02) : W202 - W206