Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients

被引:81
作者
Monnet, X. [1 ,2 ]
Anguel, N. [1 ,2 ]
Jozwiak, M. [1 ,2 ]
Richard, C. [1 ,2 ]
Teboul, J. -L. [1 ,2 ]
机构
[1] Hop Univ Paris Sud, Hop Bicetre, Serv Reanimat Med, F-94270 Le Kremlin Bicetre, France
[2] Univ Paris 11, Fac Med Paris Sud, EA 4046, F-94270 Le Kremlin Bicetre, France
关键词
cardiac output; measurement; equipment; monitors; measurement techniques; norepinephrine; shock; PULSE CONTOUR ANALYSIS; PULMONARY-ARTERY THERMODILUTION; WAVE-FORM ANALYSIS; MONITORING-SYSTEM; ESOPHAGEAL DOPPLER; PERFORMANCE; PRECISION; AGREEMENT; PRELOAD;
D O I
10.1093/bja/aer491
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The ability of the third-generation FloTrac/Vigileo software to track changes in cardiac index (CI) induced by volume expansion and norepinephrine in critically ill patients is unknown. In subjects with circulatory failure, we administered volume expansion (20 subjects) and increased (20 subjects) or decreased (20 subjects) the dose of norepinephrine. We measured arterial pressure waveform-derived CI provided by the third-generation FloTrac/Vigileo device (CIpw) and transpulmonary thermodilution CI (CItd) before and after therapeutic interventions. Considering the pairs of measurements performed before and after all therapeutic interventions (n60), a bias between the absolute values of CIpw and CItd was 0.26 (0.94) litre min(1) m(2) and the percentage error was 54. Changes in CIpw tracked changes in CItd induced by volume expansion with moderate accuracy [n20, bias0.11 (0.54) litre min(1) m(2), r(2)0.26, P0.02]. When changes in CItd were induced by norepinephrine (n40), a bias between CIpw and CItd was 0.01 (0.41) litre min(1) m(2) (r(2)0.11, P0.04). The concordance rates between changes in CIpw and CItd induced by volume expansion and norepinephrine were 73 and 60, respectively. The bias between changes in CIpw and CItd significantly correlated with changes in total systemic vascular resistance (r(2)0.41, P0.0001). The third-generation FloTrac/Vigileo device was moderately reliable for tracking changes in CI induced by volume expansion and poorly reliable for tracking changes in CI induced by norepinephrine.
引用
收藏
页码:615 / 622
页数:8
相关论文
共 33 条
[21]   RETRACTED: Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery (Retracted Article) [J].
Mayer, J. ;
Boldt, J. ;
Schoellhorn, T. ;
Roehm, K. D. ;
Mengistu, A. M. ;
Suttner, S. .
BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (02) :176-182
[22]   The Impact of Phenylephrine, Ephedrine, and Increased Preload on Third-Generation Vigileo-FloTrac and Esophageal Doppler Cardiac Output Measurements [J].
Meng, Lingzhong ;
Nam Phuong Tran ;
Alexander, Brenton S. ;
Laning, Kathleen ;
Chen, Guo ;
Kain, Zeev N. ;
Cannesson, Maxime .
ANESTHESIA AND ANALGESIA, 2011, 113 (04) :751-757
[23]   Performance of cardiac output measurement derived from arterial pressure waveform analysis in patients requiring high-dose vasopressor therapy [J].
Metzelder, S. ;
Coburn, M. ;
Fries, M. ;
Reinges, M. ;
Reich, S. ;
Rossaint, R. ;
Marx, G. ;
Rex, S. .
BRITISH JOURNAL OF ANAESTHESIA, 2011, 106 (06) :776-784
[24]   Precision of the transpulmonary thermodilution measurements [J].
Monnet, Xavier ;
Persichini, Romain ;
Ktari, Mariem ;
Jozwiak, Mathieu ;
Richard, Christian ;
Teboul, Jean-Louis .
CRITICAL CARE, 2011, 15 (04)
[25]   Arterial pressure allows monitoring the changes in cardiac output induced by volume expansion but not by norepinephrine [J].
Monnet, Xavier ;
Letierce, Alexia ;
Hamzaoui, Olfa ;
Chemla, Denis ;
Anguel, Nadia ;
Osman, David ;
Richard, Christian ;
Teboul, Jean-Louis .
CRITICAL CARE MEDICINE, 2011, 39 (06) :1394-1399
[26]   Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices [J].
Monnet, Xavier ;
Anguel, Nadia ;
Naudin, Brice ;
Jabot, Julien ;
Richard, Christian ;
Teboul, Jean-Louis .
CRITICAL CARE, 2010, 14 (03)
[27]   A pilot assessment of the FloTrac™ cardiac output monitoring system [J].
Opdam, Helen Ingrid ;
Wan, Li ;
Bellomo, Rinaldo .
INTENSIVE CARE MEDICINE, 2007, 33 (02) :344-349
[28]   Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration [J].
Prasser C. ;
Bele S. ;
Keyl C. ;
Schweiger S. ;
Trabold B. ;
Amann M. ;
Welnhofer J. ;
Wiesenack C. .
BMC Anesthesiology, 7 (1)
[29]   Pulmonary artery catheter monitoring in 2011 [J].
Richard, Christian ;
Monnet, Xavier ;
Teboul, Jean-Louis .
CURRENT OPINION IN CRITICAL CARE, 2011, 17 (03) :296-302
[30]  
Rödig G, 1999, BRIT J ANAESTH, V82, P525