Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients

被引:81
作者
Monnet, X. [1 ,2 ]
Anguel, N. [1 ,2 ]
Jozwiak, M. [1 ,2 ]
Richard, C. [1 ,2 ]
Teboul, J. -L. [1 ,2 ]
机构
[1] Hop Univ Paris Sud, Hop Bicetre, Serv Reanimat Med, F-94270 Le Kremlin Bicetre, France
[2] Univ Paris 11, Fac Med Paris Sud, EA 4046, F-94270 Le Kremlin Bicetre, France
关键词
cardiac output; measurement; equipment; monitors; measurement techniques; norepinephrine; shock; PULSE CONTOUR ANALYSIS; PULMONARY-ARTERY THERMODILUTION; WAVE-FORM ANALYSIS; MONITORING-SYSTEM; ESOPHAGEAL DOPPLER; PERFORMANCE; PRECISION; AGREEMENT; PRELOAD;
D O I
10.1093/bja/aer491
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The ability of the third-generation FloTrac/Vigileo software to track changes in cardiac index (CI) induced by volume expansion and norepinephrine in critically ill patients is unknown. In subjects with circulatory failure, we administered volume expansion (20 subjects) and increased (20 subjects) or decreased (20 subjects) the dose of norepinephrine. We measured arterial pressure waveform-derived CI provided by the third-generation FloTrac/Vigileo device (CIpw) and transpulmonary thermodilution CI (CItd) before and after therapeutic interventions. Considering the pairs of measurements performed before and after all therapeutic interventions (n60), a bias between the absolute values of CIpw and CItd was 0.26 (0.94) litre min(1) m(2) and the percentage error was 54. Changes in CIpw tracked changes in CItd induced by volume expansion with moderate accuracy [n20, bias0.11 (0.54) litre min(1) m(2), r(2)0.26, P0.02]. When changes in CItd were induced by norepinephrine (n40), a bias between CIpw and CItd was 0.01 (0.41) litre min(1) m(2) (r(2)0.11, P0.04). The concordance rates between changes in CIpw and CItd induced by volume expansion and norepinephrine were 73 and 60, respectively. The bias between changes in CIpw and CItd significantly correlated with changes in total systemic vascular resistance (r(2)0.41, P0.0001). The third-generation FloTrac/Vigileo device was moderately reliable for tracking changes in CI induced by volume expansion and poorly reliable for tracking changes in CI induced by norepinephrine.
引用
收藏
页码:615 / 622
页数:8
相关论文
共 33 条
[1]  
[Anonymous], 1970, STAT METHODS RES WOR
[2]   Hemodynamic monitoring in shock and implications for management International Consensus Conference, Paris, France, 27-28 April 2006 [J].
Antonelli, Massimo ;
Levy, Mitchell ;
Andrews, Peter J. D. ;
Chastre, Jean ;
Hudson, Leonard D. ;
Manthous, Constantine ;
Meduri, G. Umberto ;
Moreno, Rui P. ;
Putensen, Christian ;
Stewart, Thomas ;
Torres, Antoni .
INTENSIVE CARE MEDICINE, 2007, 33 (04) :575-590
[3]   Comparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac output [J].
Bein, B ;
Worthmann, F ;
Tonner, PH ;
Paris, A ;
Steinfath, M ;
Hedderich, J ;
Scholz, J .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2004, 18 (02) :185-189
[4]   Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation [J].
Biais, M. ;
Nouette-Gaulain, K. ;
Cottenceau, V. ;
Revel, P. ;
Sztark, F. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (06) :761-768
[5]   Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery [J].
Biancofiore, G. ;
Critchley, L. A. H. ;
Lee, A. ;
Bindi, L. ;
Bisa, M. ;
Esposito, M. ;
Meacci, L. ;
Mozzo, R. ;
DeSimone, P. ;
Urbani, L. ;
Filipponi, F. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (01) :47-54
[6]  
Buhre G, 1999, J CARDIOTHOR VASC AN, V13, P437
[7]   Clinical evaluation of the FloTrac/Nigileo™ system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery [J].
Button, D. ;
Weibel, L. ;
Reuthebuch, O. ;
Genoni, M. ;
Zollinger, A. ;
Hofer, C. K. .
BRITISH JOURNAL OF ANAESTHESIA, 2007, 99 (03) :329-336
[8]   Comparison of FloTrac™ cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements [J].
Cannesson, M. ;
Attof, Y. ;
Rosamel, P. ;
Joseph, P. ;
Bastien, O. ;
Lehot, J.-J. .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2007, 24 (10) :832-839
[9]   Performance of a minimally invasive uncalibrated cardiac output monitoring system (Flotrac™/Vigileo™) in haemodynamically unstable patients [J].
Compton, F. D. ;
Zukunft, B. ;
Hoffmann, C. ;
Zidek, W. ;
Schaefer, J. -H. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 100 (04) :451-456
[10]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91