A comparison of stereoscopic and monoscopic evaluation of optic disc topography using a digital optic disc stereo camera

被引:34
作者
Parkin, B
Shuttleworth, G
Costen, M
Davison, C
机构
[1] Southampton Gen Hosp, Southampton Eye Unit, Southampton SO16 6YD, Hants, England
[2] Bristol Eye Hosp, Bristol BS1 2LX, Avon, England
[3] Bournemouth Hosp, Bournemouth Eye Unit, Bournemouth BH7 7DW, Dorset, England
关键词
D O I
10.1136/bjo.85.11.1347
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims-To compare stereophotographic and monophotographic optic disc assessments made using a digital optic disc stereo camera. Methods-Stereo digital optic disc photographs of 150 selected patients who had presented to a glaucoma clinic were assessed by two masked observers on separate occasions using (1) the stereophotographs and a stereoviewer, (2) a single image from the same stereopair. Results were analysed for both right and left eyes separately. 95% tolerance limits for change (TC) and intraclass correlation coefficients (ICC) were calculated and a multivariate analysis using a general linear model for repeated measures was performed. Results-A total of 201 optic disc images of 150 patients (84 females, 108 left eyes) were analysed. Mean age of patients was 64 years. The results for right eyes are as follows (similar results were obtained for left eyes). Intraobserver (stereoscopic compared to monoscopic) measurements of. horizontal cup:disc ratios (CDR), ICC = 0.5995 and 0.7269, TC = 34% and 27%; vertical CDR, ICC = 0.8298 and 0.817, TC = 25% and 27%; area CDR, ICC = 0.7757 and 0.8259, TC = 28% and 25%; circumference CDR, ICC = 0.7618 and 0.8103, TC = 28% and 25%. Interobserver measurements of. horizontal CDR, ICC stereoscopic (SS) = 0.7287; monoscopic (MS) = 0.5030; TC SS = 30%; MS = 32%; vertical CDR, ICC SS = 0.8439; MS = 0.7106; TC SS = 25%; MS = 31%; area CDR, ICC SS = 0.8392; MS = 0.6276; TC SS = 26%; MS = 32%; circumference CDR, ICC SS = 0.8433; MS = 0.6438, TC SS = 26%; MS = 31%. Systematic bias between observers and between methods was within acceptable limits. Conclusions-This study using a digital stereo camera indicates that there may be little benefit of stereoscopic imaging over monoscopic imaging despite demonstrating small but inconsistent differences between both observers and methods.
引用
收藏
页码:1347 / 1351
页数:5
相关论文
共 13 条
[1]  
ABRAMS LS, 1994, OPHTHALMOLOGY, V101, P1662
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Boes DA, 1996, J GLAUCOMA, V5, P9
[4]   STANDARDIZING DIAGNOSTIC PROCEDURES [J].
KAHN, HA ;
LEIBOWITZ, H ;
GANLEY, JP ;
KINI, M ;
COLTON, T ;
NICKERSON, R ;
DAWBER, TR .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1975, 79 (05) :768-775
[5]  
KLEIN BEK, 1987, OPHTHALMOLOGY, V94, P1481
[6]   COMPARISON OF PHOTOGRAPHIC TECHNIQUES AND FILMS USED IN STEREOPHOTOGRAMMETRY OF THE OPTIC DISK [J].
KROHN, MA ;
KELTNER, JL ;
JOHNSON, CA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1979, 88 (05) :859-863
[7]  
Lichter PR., 1977, Trans Am Ophthalmol Soc No, V74, P532
[8]  
ROSENTHAL AR, 1977, INVEST OPHTH VIS SCI, V16, P54
[9]   METHODOLOGIC DIFFERENCES AND MEASUREMENT OF CUP-DISC RATIO - EPIDEMIOLOGIC ASSESSMENT [J].
SCHWARTZ, JT .
ARCHIVES OF OPHTHALMOLOGY, 1976, 94 (07) :1101-1105
[10]   A new digital optic disc stereo camera: intraobserver and interobserver repeatability of optic disc measurements [J].
Shuttleworth, GN ;
Khong, CH ;
Diamond, JP .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2000, 84 (04) :403-407