Biosensor for the evaluation of biochemical oxygen demand using photocatalytic pretreatment

被引:16
作者
Chee, GJ [1 ]
Nomura, Y [1 ]
Ikebukuro, K [1 ]
Karube, I [1 ]
机构
[1] Univ Tokyo, Adv Sci & Technol Res Ctr, Meguro Ku, Tokyo 1538904, Japan
关键词
BOD sensor; biosensor; Pseudomonas putida; artificial wastewater; photocatalysis; TiO2; UV; pretreatment;
D O I
10.1016/S0925-4005(01)00883-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive biochemical oxygen demand (BOD) sensor using photocatalytic pretreatment was developed to evaluate low BOD levels in river waters. The photocatalytic oxidation was carried out in a commercial TiO2 as a semiconductor and a 6 W black-light tube as light sources. The photocatalytic oxidation was investigated about the effects of irradiation times, TiO2 concentrations, and pH on the sensor response. The optimal irradiation time was 4 min. TiO2 concentrations gave the optimum response to the BOD sensor at 1% (w/v). The sensor response was increased with increasing pH. The sensor responses obtained by photocatalysis to river samples were higher than those obtained without photocatalysis, A fairly good correlation between the values obtained by the photocatalytic pretreatment method and BOD5 was acquired. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:15 / 20
页数:6
相关论文
共 40 条
[1]   MECHANISTIC STUDIES OF WATER DETOXIFICATION IN ILLUMINATED TIO2 SUSPENSIONS [J].
BAHNEMANN, D ;
BOCKELMANN, D ;
GOSLICH, R .
SOLAR ENERGY MATERIALS, 1991, 24 (1-4) :564-583
[3]   A preliminary investigation on the photocatalytic degradation of a model humic acid [J].
Bekbolet, M ;
Ozkosemen, G .
WATER SCIENCE AND TECHNOLOGY, 1996, 33 (06) :189-194
[4]   Enhancement of the biodegradability of model wastewater containing recalcitrant or inhibitory chemical compounds by photocatalytic pre-oxidation [J].
Bolduc, L ;
Anderson, WA .
BIODEGRADATION, 1997, 8 (04) :237-249
[5]   BIOCHEMICAL ASPECTS OF BIOSENSORS [J].
BYFIELD, MP ;
ABUKNESHA, RA .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (4-5) :373-400
[6]   Development of highly sensitive BOD sensor and its evaluation using preozonation [J].
Chee, GJ ;
Nomura, Y ;
Ikebukuro, K ;
Karube, I .
ANALYTICA CHIMICA ACTA, 1999, 394 (01) :65-71
[7]   Biosensor for the estimation of low biochemical oxygen demand [J].
Chee, GJ ;
Nomura, Y ;
Karube, I .
ANALYTICA CHIMICA ACTA, 1999, 379 (1-2) :185-191
[8]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[9]   Flow-injection determination of catechol with a new tyrosinase/DNA biosensor [J].
Dantoni, P ;
Serrano, SHP ;
Brett, AMO ;
Gutz, IGR .
ANALYTICA CHIMICA ACTA, 1998, 366 (1-3) :137-145
[10]  
EGERTON TA, 1979, J OIL COLOUR CHEM AS, V62, P386