Determination of wires transfer length in prestressed concrete members with different levels of corrosion

被引:8
|
作者
Anaya, P. [1 ]
Rodriguez, J. [2 ]
Andrade, C. [3 ]
Martin-Perez, B. [4 ]
Lopez Hombrados, C. [5 ]
机构
[1] Univ Politecn Madrid UPM, Madrid, Spain
[2] Univ Politecn Madrid ETSAM UPM, Madrid, Spain
[3] Ctr Intern Metodos Numer Ingn CIMNE, Madrid, Spain
[4] Univ Ottawa, Ottawa, ON, Canada
[5] CSIC, Inst Ciencias Construcc Eduardo Torroja IETcc, Madrid, Spain
关键词
Transfer length; transmission length; prestressed concrete; bond; corrosion; analytical model; COVER-CRACKING; PREDICTION; MODEL;
D O I
10.3989/ic.71428
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Bond between steel and concrete in prestressed concrete members may be degraded due to different reasons, being one of the most frequent ones the corrosion induced damage. Transfer length is the key indicator to describe the bond properties between prestressed steel and concrete. Through tests on prestressed beams, this paper is focused on the experimental verification of an analytical model developed to analyse the processes of bond degradation due to the corrosion of both indented and smooth wires, and its influence on the behaviour of prestressed concrete members. The model is based on both the thick-walled cylinder theory and the cohesive cracking for concrete.
引用
收藏
页码:1 / 10
页数:12
相关论文
共 42 条
  • [21] A practical approach for finite-element modeling of transfer length in pretensioned, prestressed concrete members using end-slip methodology
    Carroll, J. Chris
    Cousins, Thomas E.
    Roberts-Wollmann, Carin L.
    PCI Journal, 2014, 59 (03): : 110 - 129
  • [22] Experimental study on transfer length of an eco-friendly prestressed concrete sleeper
    Koh, Taehoon
    Bae, Younghoon
    Shin, Moochul
    Hwang, Seonkeun
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 109 : 25 - 33
  • [23] Evaluation of the transfer length of prestressed near surface mounted CFRP rods in concrete
    Badawi, Moataz
    Wahab, Noran
    Soudki, Khaled
    CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (03) : 1474 - 1479
  • [24] In-situ deformation modulus of rust in concrete under different levels of confinement and rates of corrosion
    Liu, Qifang
    Su, Ray Kai Leung
    Li, Chun-Qing
    Shih, Kaimin
    Liao, Changzhong
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 255
  • [25] Transfer length of 2400 MPa seven-wire 15.2 mm steel strands in high -strength pretensioned prestressed concrete beam
    Yang, Jun-Mo
    Yim, Hong-Jae
    Kim, Jin-Kook
    SMART STRUCTURES AND SYSTEMS, 2016, 17 (04) : 577 - 591
  • [26] Transfer Length in Prestressed Self-Consolidating Concrete Box and I-Girders
    Pozolo, Andrew M.
    Andrawes, Bassem
    ACI STRUCTURAL JOURNAL, 2011, 108 (03) : 341 - 349
  • [27] Transfer Length and Prestress Losses of a Prestressed Concrete Box Girder with 18 mm Straight Strands
    Jiang, Xin
    Chen, Haoxuan
    Zhou, Yongjun
    Ma, Lin
    Du, Jianqun
    Zhang, Wei
    Li, Yunli
    BUILDINGS, 2023, 13 (08)
  • [28] MECHANICAL PROPERTIES OF TWO-WAY DIFFERENT CONFIGURATIONS OF PRESTRESSED CONCRETE MEMBERS SUBJECTED TO AXIAL LOADING
    Zhang, Chaobi
    Chen, Jianyun
    Xu, Qiang
    Li, Jing
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2015, 47 (05) : 633 - 645
  • [29] Transfer and development length of high-strength duplex stainless steel strand in prestressed concrete piles
    Paul, Alvaro
    Gleich, Lorintz B.
    Kahn, Lawrence F.
    PCI JOURNAL, 2017, : 59 - 71
  • [30] Influence of strand rupture on flexural behavior of reduced-scale prestressed concrete bridge girders with different prestressing levels
    Losanno, Daniele
    Galano, Simone
    Parisi, Fulvio
    ENGINEERING STRUCTURES, 2024, 301