Diagnostic reference levels (DRLs) for routine X-ray examinations in Lorestan province, Iran

被引:0
|
作者
Gholami, M. [1 ]
Maziar, A. [2 ]
Khosravi, H. R. [3 ]
Ebrahimzadeh, F. [4 ]
Mayahi, S. [1 ]
机构
[1] Lorestan Univ Med Sci, Fac Allied Med Sci, Dept Med Phys & Radiat Sci, Khorramabad, Iran
[2] Isfahan Univ Med Sci, Fac Med, Dept Med Phys & Med Engn, Esfahan, Iran
[3] Atom Energy Org Iran, Tehran, Iran
[4] Lorestan Univ Med Sci, Fac Hlth & Nutr, Dept Biostat, Khorramabad, Iran
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2015年 / 13卷 / 01期
关键词
Diagnostic radiology; ESAK; patient dose; Lorestan province; quality control; DOSE MEASUREMENTS; ENTRANCE SURFACE; EXPOSURES; BRAZIL; CHEST; UK;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In diagnostic radiology there are two reasons for measuring or estimating radiation doses to patients. Firstly measurements provide a means for setting and checking standards of good practice as an aid to the optimization of patient protection. Secondly estimates of the absorbed dose to tissue and organs in the patients. Material and Methods: A total of 2382 patients were studied to calculate the Entrance Surface Air Kerma (ESAK) following seven radiographic examinations including: chest (PA, Lat), lumbar spines (AP, Lat), pelvis (AP), abdomen (AP), skull (PA, Lat), thoracic spine (AP, Lat) and cervical spines (AP, Lat). The ESAKs values were measured according to x- ray tube output, optimized exposure parameters and body thickness (tp) for each technique. Results: The parameters such as, 1st quartile, mean, median, 3rd quartile, minimum, maximum and standard deviation of each ESAK values are reported and compared to NRPB guide levels. The results showed that the ESAKs values in the lumbar spines and chest X-ray examinations were 30% above the guide levels. However, for the pelvis (AP), skull (PA) and abdomen (AP) examinations, these values were below than those reported by the NRPB. Conclusion: Periodic quality control and monitoring the technical performance of radiographers might effectively improve the image quality and eventually reducing the dose received by patients.
引用
收藏
页码:85 / 90
页数:6
相关论文
共 50 条
  • [21] Reconstruction of doses from occupationally related medical X-ray examinations
    Shockley, Vernon E.
    Kathren, Ronald L.
    Thomas, Elyse M.
    HEALTH PHYSICS, 2008, 95 (01): : 107 - 118
  • [22] A compliance testing program for diagnostic X-ray equipment
    Hutchinson, DE
    Cobb, BJ
    Jacob, CS
    APPLIED RADIATION AND ISOTOPES, 1999, 50 (01) : 237 - 245
  • [23] Assessment of entrance skin dose for adult patients undergoing diagnostic X-ray examinations in the Souss-Massa region of Morocco
    El Fahssi, M.
    Semghouli, S.
    Amaoui, B.
    Jroundi, L.
    Caoui, M.
    RADIOPROTECTION, 2023, 58 (02) : 107 - 112
  • [24] LOCAL STUDY OF DIAGNOSTIC REFERENCE LEVELS FOR COMPUTED TOMOGRAPHY EXAMINATIONS OF ADULT PATIENTS IN IZMIR, TURKEY
    Yurt, Aysegul
    Ozsoykal, Ismail
    Kandemir, Recep
    Ada, Emel
    RADIATION PROTECTION DOSIMETRY, 2020, 190 (04) : 446 - 451
  • [25] A survey on the determination of diagnostic reference levels in analog and digital radiography in Iran: a systematic literature review
    Ghazizadeh, Mehdi
    Deevband, Mohammad Reza
    Kardan, Mohammad Reza
    Tavakoli, Meysam
    RADIATION PROTECTION DOSIMETRY, 2025, : 432 - 440
  • [26] Proposed Guidelines for Image Quality Optimization in Chest PA X-Ray Examinations In Bangladesh
    Khan, Shahed
    Santos, Eleonora
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 795 - 797
  • [27] Routine control of accuracy in silicate rock analysis by X-ray fluorescence spectrometry
    Vendemiatto, MA
    Enzweiler, J
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2001, 25 (2-3): : 283 - 291
  • [28] Establishing local diagnostic reference levels for computed tomography examinations using size-specific dose estimates
    Alrehily, Faisal A.
    Alqahtani, Khalid S.
    Aljohani, Marwan H.
    Alharbi, Nawaf S.
    Alharbi, Reyan M.
    Abdulaal, Osamah M.
    Alshamrani, Abdullah F.
    Alsaedi, Abdulrahman S.
    Al-Murshedi, Sadeq H.
    Alhazmi, Fahad H.
    SAUDI MEDICAL JOURNAL, 2023, 44 (08) : 761 - 766
  • [29] Assessment of the radiation dose associated with X-ray examinations using the DoseCal and CALDose_X software packages
    Saeed, M. K.
    Almalki, Y.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (01): : 191 - 197
  • [30] Definitions and outlook targeting x-ray exposure of patients in diagnostic imaging
    Regulla, Dieter F.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961