Diagnostic reference levels (DRLs) for routine X-ray examinations in Lorestan province, Iran

被引:0
|
作者
Gholami, M. [1 ]
Maziar, A. [2 ]
Khosravi, H. R. [3 ]
Ebrahimzadeh, F. [4 ]
Mayahi, S. [1 ]
机构
[1] Lorestan Univ Med Sci, Fac Allied Med Sci, Dept Med Phys & Radiat Sci, Khorramabad, Iran
[2] Isfahan Univ Med Sci, Fac Med, Dept Med Phys & Med Engn, Esfahan, Iran
[3] Atom Energy Org Iran, Tehran, Iran
[4] Lorestan Univ Med Sci, Fac Hlth & Nutr, Dept Biostat, Khorramabad, Iran
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2015年 / 13卷 / 01期
关键词
Diagnostic radiology; ESAK; patient dose; Lorestan province; quality control; DOSE MEASUREMENTS; ENTRANCE SURFACE; EXPOSURES; BRAZIL; CHEST; UK;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In diagnostic radiology there are two reasons for measuring or estimating radiation doses to patients. Firstly measurements provide a means for setting and checking standards of good practice as an aid to the optimization of patient protection. Secondly estimates of the absorbed dose to tissue and organs in the patients. Material and Methods: A total of 2382 patients were studied to calculate the Entrance Surface Air Kerma (ESAK) following seven radiographic examinations including: chest (PA, Lat), lumbar spines (AP, Lat), pelvis (AP), abdomen (AP), skull (PA, Lat), thoracic spine (AP, Lat) and cervical spines (AP, Lat). The ESAKs values were measured according to x- ray tube output, optimized exposure parameters and body thickness (tp) for each technique. Results: The parameters such as, 1st quartile, mean, median, 3rd quartile, minimum, maximum and standard deviation of each ESAK values are reported and compared to NRPB guide levels. The results showed that the ESAKs values in the lumbar spines and chest X-ray examinations were 30% above the guide levels. However, for the pelvis (AP), skull (PA) and abdomen (AP) examinations, these values were below than those reported by the NRPB. Conclusion: Periodic quality control and monitoring the technical performance of radiographers might effectively improve the image quality and eventually reducing the dose received by patients.
引用
收藏
页码:85 / 90
页数:6
相关论文
共 50 条
  • [1] Diagnostic reference levels for X-ray examinations
    Veit, R.
    Guggenberger, R.
    Nosske, D.
    Brix, G.
    RADIOLOGE, 2010, 50 (10): : 907 - +
  • [2] Preliminary Values of Diagnostic Reference Level for Selected X-Ray Examinations in Indonesia
    Hiswara, E.
    Prasetio, H.
    Kartikasari, D.
    Nuraeni, N.
    Sandy, K. Y. P.
    ATOM INDONESIA, 2016, 42 (03) : 99 - 104
  • [3] Diagnostic Reference Levels for Common X-ray Procedures in Peru
    Portocarrero Bonifaz, Andres
    Camarena Rodriguez, Caterina S.
    Palma Esparza, Ricardo
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (10)
  • [4] Patient dose measurement in common medical X-ray examinations in Iran
    Rasuli, Behrouz
    Mahmoud-Pashazadeh, Ali
    Ghorbani, Mohammad
    Juybari, Raheleh Tabari
    Naserpour, Mozafar
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 374 - 386
  • [5] Radiation dose measurement for patients undergoing common spine medical x-ray examinations and proposed local diagnostic reference levels
    Rasuli, Behrouz
    Ghorbani, Mohammad
    Juybari, Raheleh Tabari
    RADIATION MEASUREMENTS, 2016, 87 : 29 - 34
  • [6] The Establishment of Institutional Diagnostic Reference Levels (DRLs) in the Cipto Mangunkusumo Hospital
    Amalia, T.
    Zulkarnaien, B.
    Anam, C.
    Nurcahyo, K.
    Tussyadiah, H.
    Pradana, D. E.
    ATOM INDONESIA, 2022, 48 (02) : 159 - 167
  • [7] Evaluation of the Entrance Surface Doses (ESD) for common diagnostic X-ray examinations
    Alomairy, Nada
    Hadi, Dareen
    Al-Zaid, Amna
    Fasikh, Rawan
    Arif, Raneem
    Al-Hazmi, Rawan
    Kharizy, Ali
    Alyami, Ali
    Hummdy, Ahmed
    Shubayr, Nasser
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2023, 16 (04)
  • [8] Normalized organ doses and effective doses to a reference Indian adult male in conventional medical diagnostic x-ray examinations
    Biju, K
    Nagarajan, PS
    HEALTH PHYSICS, 2006, 90 (03): : 217 - 222
  • [9] Radiation levels and image quality in patients undergoing chest X-ray examinations
    Campos de Oliveira, Paulo Marcio
    Santana, Priscila do Carmo
    de Sousa Lacerda, Marco Aurelio
    da Silva, Teogenes Augusto
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 305 - 308
  • [10] Effective Dose Calculations in Conventional Diagnostic X-Ray Examinations for Patients in Major Sudanese Hospitals
    Suliman, I. I.
    Habbani, F. I.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2087 - +