Novel water permeability device for reinforced concrete under load

被引:27
作者
Desmettre, C. [1 ]
Charron, J. -P. [1 ]
机构
[1] Ecole Polytech Montreal, Res Ctr Concrete Infrastruct CRIB, Grp Res Struct Engn, Montreal, PQ, Canada
关键词
Reinforced concrete; Water permeability; Crack width; Stress in reinforcing bar; Tensile loading; Pressure gradient; Pressure regulation; Loading rate; Loading control mode; Design criteria; CRACKED CONCRETE; FIBER REINFORCEMENT; TENSION;
D O I
10.1617/s11527-011-9729-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The presence of cracks in reinforced concrete structures is recognized to increase the penetration of water and aggressive agents into concrete and thus accelerate its deterioration. In order to gain knowledge on the influence of cracking on concrete durability and assess admissible loads to ensure long-term performance of structures, an innovative water permeability device was developed to estimate water flow in plain and cracked reinforced concrete. Permeability measurements were taken simultaneously with the application of a uniaxial tensile load on the testing specimen. The device permitted the estimation of the average stress in the reinforcing bar and the maximum crack opening in the concrete specimen. The experimental program comprised studies on result repeatability and the influence of testing parameters, such as pressure gradient, pressure regulation, loading rate and loading control mode. Test results showed that the modification of the testing parameters had a negligible impact on water permeability. Moreover, correlations were established between the water permeability, the average stress in the steel reinforcement, and the crack opening width in the reinforced concrete. Analysis of the results demonstrated the potential of the research results to improve the design criteria of reinforced concrete at serviceability limit states.
引用
收藏
页码:1713 / 1723
页数:11
相关论文
共 27 条
[1]  
*ACI, 2003, BUILD COD REQ STRUCT
[2]  
Al-Fayadh S., 1997, Dans Research report: tension of reinforced concrete prisms vol, V13, P1
[3]  
Aldea CM, 2000, ACI MATER J, V97, P567
[4]   Permeability of cracked concrete [J].
Aldea, CM ;
Shah, SP ;
Karr, A .
MATERIALS AND STRUCTURES, 1999, 32 (219) :370-376
[5]  
*BAEL, 1999, REGL BAEL 91 MOD 99
[6]  
Banthia N, 2007, ACI MATER J, V104, P70
[7]   Permeability of concrete with fiber reinforcement and service life predictions [J].
Bhargava, Ankit ;
Banthia, Nemkumar .
MATERIALS AND STRUCTURES, 2008, 41 (02) :363-372
[8]  
BREYSSE D, 1997, PENETRATION PERMEABI, V16, P123
[9]  
*BRIT STAND I, 1997, 811021985 BRIT STAND
[10]  
Canadian Standards Association, 2004, CANCSAA23304