ISCEV standard for clinical multifocal electroretinography (mfERG) (2011 edition)

被引:471
作者
Hood, Donald C. [1 ,2 ]
Bach, Michael [3 ]
Brigell, Mitchell [4 ]
Keating, David [5 ]
Kondo, Mineo [6 ]
Lyons, Jonathan S. [7 ]
Marmor, Michael F. [8 ]
McCulloch, Daphne L. [9 ]
Palmowski-Wolfe, Anja M. [10 ]
机构
[1] Columbia Univ, Dept Psychol, New York, NY 10027 USA
[2] Columbia Univ, Dept Ophthalmol, New York, NY 10027 USA
[3] Univ Augenklin, Freiburg, Germany
[4] Novartis Inst Biomed Res, Cambridge, MA USA
[5] Gartnavel Royal Hosp, Dept Ophthalmol, Glasgow, Lanark, Scotland
[6] Mie Univ, Dept Ophthalmol, Grad Sch Med, Tsu, Mie 514, Japan
[7] Georgetown Univ, Washington Hosp, Ctr Program Ophthalmol, Silver Spring, MD USA
[8] Stanford Univ, Sch Med, Byers Eye Inst Stanford, Palo Alto, CA 94304 USA
[9] Glasgow Caledonian Univ, Vis Sci, Glasgow G4 0BA, Lanark, Scotland
[10] Univ Basel, Dept Ophthalmol, Basel, Switzerland
关键词
Clinical guidelines; Electroretinogram; Multifocal electroretinogram; GUIDELINES; UPDATE;
D O I
10.1007/s10633-011-9296-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The clinical multifocal electroretinogram (mfERG) is an electrophysiological test of local retinal function. With this technique, many local ERG responses are recorded quasi-simultaneously from the cone-driven retina under light-adapted conditions. This document, from the International Society for Clinical Electrophysiology of Vision (ISCEV: www.iscev.org), replaces the ISCEV guidelines for the mfERG published in 2007. Standards for performance of the basic clinical mfERG test with a stimulus array of 61 or 103 hexagons, as well as for reporting the results, are specified.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 7 条
[1]   Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision [J].
Brigell, M ;
Bach, M ;
Barber, C ;
Moskowitz, A ;
Robson, J .
DOCUMENTA OPHTHALMOLOGICA, 2003, 107 (02) :185-193
[2]   ISCEV standard for clinical pattern electroretinography - 2007 update [J].
Holder, Graham E. ;
Brigell, Mitchell G. ;
Hawlina, Marko ;
Meigen, Thomas ;
Vaegan ;
Bach, Michael .
DOCUMENTA OPHTHALMOLOGICA, 2007, 114 (03) :111-116
[3]   ISCEV guidelines for clinical multifocal electroretinography (2007 edition) [J].
Hood, Donald C. ;
Bach, Michael ;
Brigell, Mitchell ;
Keating, David ;
Kondo, Mineo ;
Lyons, Jonathan S. ;
Palmowski-Wolfe, Anja M. .
DOCUMENTA OPHTHALMOLOGICA, 2008, 116 (01) :1-11
[4]   ISCEV Standard for full-field clinical electroretinography (2008 update) [J].
Marmor, M. F. ;
Fulton, A. B. ;
Holder, G. E. ;
Miyake, Y. ;
Brigell, M. ;
Bach, M. .
DOCUMENTA OPHTHALMOLOGICA, 2009, 118 (01) :69-77
[5]   Guidelines for basic multifocal electroretinography (mfERG) [J].
Marmor, MF ;
Hood, DC ;
Keating, D ;
Kondo, M ;
Seeliger, MW ;
Miyake, Y .
DOCUMENTA OPHTHALMOLOGICA, 2003, 106 (02) :105-115
[6]   ISCEV standard for clinical electro-oculography (2010 update) [J].
Marmor, Michael F. ;
Brigell, Mitchell G. ;
McCulloch, Daphne L. ;
Westall, Carol A. ;
Bach, Michael .
DOCUMENTA OPHTHALMOLOGICA, 2011, 122 (01) :1-7
[7]   ISCEV standard for clinical visual evoked potentials (2009 update) [J].
Odom, J. Vernon ;
Bach, Michael ;
Brigell, Mitchell ;
Holder, Graham E. ;
McCulloch, Daphne L. ;
Tormene, Alma Patrizia ;
Vaegan .
DOCUMENTA OPHTHALMOLOGICA, 2010, 120 (01) :111-119