The accuracy of instrumental neutron activation analysis of kilogram-size inhomogeneous samples

被引:13
作者
Blaauw, M
Lakmaker, O
vanAller, P
机构
[1] Interfaculty Reactor Institute, 2629 JB Delft
关键词
D O I
10.1021/ac961280x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The feasibility of quantitative instrumental neutron activation analysis (INAA) of samples in the kilogram range without internal standardization has been demonstrated by Overwater et al. (Anal. Chem. 1996, 68, 341). In their studies, however, they demonstrated only the agreement between the ''corrected'' gamma ray spectrum of homogeneous large samples and that of small samples of the same material. In this paper, the k(0) calibration of the IRI facilities for large samples is described, and, this time in terms of (trace) element concentrations, some of Overwater's results for homogeneous materials are presented again, as well as results obtained from inhomogeneous materials and subsamples thereof. It is concluded that large-sample INAA can be as accurate as ordinary INAA, even when applied to inhomogeneous materials.
引用
收藏
页码:2247 / 2250
页数:4
相关论文
共 10 条
[1]   Neutron induced gamma-ray emission tomography [J].
Balogun, FA ;
Spyrou, NM ;
Adesanmi, CA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 114 (3-4) :387-393
[2]   THE HOLISTIC ANALYSIS OF GAMMA-RAY SPECTRA IN INSTRUMENTAL NEUTRON-ACTIVATION ANALYSIS [J].
BLAAUW, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :269-271
[3]   COMPARISON OF THE CATALOGS OF THE K(O) AND THE K(ZN) SINGLE COMPARATOR METHODS FOR STANDARDIZATION IN INAA [J].
BLAAUW, M .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1995, 191 (02) :387-401
[4]   INTRODUCTION OF THE K(1)-CONCEPT FOR THE INTERPRETATION OF ARTIFICIAL PEAKS IN K(0)-BASED NAA [J].
BLAAUW, M ;
BODE, P .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1993, 169 (01) :201-208
[5]  
Blaauw M., 1996, K0 CONSISTENT IRI GA
[7]   Feasibility of elemental analysis of kilogram-size samples by instrumental neutron activation analysis [J].
Overwater, RMW ;
Bode, P ;
deGoeij, JJM ;
Hoogenboom, JE .
ANALYTICAL CHEMISTRY, 1996, 68 (02) :341-348
[8]   ACCOUNTING FOR THE THERMAL-NEUTRON FLUX DEPRESSION IN VOLUMINOUS SAMPLES FOR INSTRUMENTAL NEUTRON-ACTIVATION ANALYSIS [J].
OVERWATER, RMW ;
HOOGENBOOM, JE .
NUCLEAR SCIENCE AND ENGINEERING, 1994, 117 (03) :141-157
[9]   SINGLE-COMPARATOR METHODS IN REACTOR NEUTRON-ACTIVATION ANALYSIS [J].
SIMONITS, A ;
DECORTE, F ;
HOSTE, J .
JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1975, 24 (01) :31-46
[10]   Nondestructive determination of major elements in a large sample by prompt gamma ray neutron activation analysis [J].
Sueki, K ;
Kobayashi, K ;
Sato, W ;
Nakahara, H ;
Tomizawa, T .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2203-2209