Thermal performance of an absorption-refrigeration system with [emim]Cu2Cl5/NH3 as working fluid

被引:31
|
作者
Chen, Wei [1 ]
Bai, Yang [1 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Electromech Engn, Qingdao 266061, Peoples R China
基金
中国国家自然科学基金;
关键词
emim]Cu2Cl5/NH3; Vapor liquid equilibrium; UNIFAC model; Absorption refrigeration; Thermal performance; VAPOR-LIQUID-EQUILIBRIA; IONIC LIQUIDS; UNIFAC; DIMETHYLPHOSPHATE; TEMPERATURE; ABSORBENTS; EQUATION; WATER; PAIRS; LAW;
D O I
10.1016/j.energy.2016.06.093
中图分类号
O414.1 [热力学];
学科分类号
摘要
The vapor pressures of [emim]Cu2Cl5/NH3 at ammonia mole fractions (x(1)) ranging from 0.90 to 0.96 at temperatures (T) ranging from 303.15 K to 483.15 K were determined by employing a static method. The correlation of experimental data was calculated by using a modified UNIFAC (Dortmund) model with a total uncertainty of <4.1%. The specific enthalpy of [emim]Cu2Cl5/NH3 binary solution was also calculated on the basis of the predictive excess molar enthalpy of the UNIFAC model. The thermal performance of an absorption refrigeration system with [emim]Cu2Cl5/NH3 as working fluid was simulated. The thermal performance of the [emim]Cu2Cl5/NH3 system is better than those of absorption systems with NH3/H2O, [choline][NTf2]/NH3, [emim][Ac]/NH3, and [emimj[EtOSO3]/NH3 as working fluids. The coefficients of performance and exergy efficiency of the [emim]Cu2Cl5/NH3 system are slightly lower than those of the LiBr/H2O system. The evaporating temperature scope of the former is wider than that of the latter. The [emim]Cu2Cl5/NH3 system also possesses several advantages, including non-crystallization and non corrosion. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:332 / 341
页数:10
相关论文
共 50 条
  • [1] PERFORMANCE OF A LOW-TEMPERATURE NH3-H2O ABSORPTION-REFRIGERATION SYSTEM
    ROGDAKIS, ED
    ANTONOPOULOS, KA
    ENERGY, 1992, 17 (05) : 477 - 484
  • [2] INVESTIGATION OF THERMAL PERFORMANCE OF A SOLAR-POWERED ABSORPTION-REFRIGERATION SYSTEM
    DINCER, I
    EDIN, M
    TURE, IE
    ENERGY CONVERSION AND MANAGEMENT, 1995, 37 (01) : 51 - 58
  • [3] Thermodynamic analysis of an absorption system using [bmim]Zn2Cl5/NH3 as the working pair
    Chen, Wei
    Liang, Shiqiang
    Guo, Yongxian
    Tang, Dawei
    ENERGY CONVERSION AND MANAGEMENT, 2014, 85 : 13 - 19
  • [5] PERFORMANCE OF NH3/CO2 CASCADE REFRIGERATION SYSTEM WITH EJECTOR
    Pratihar, A. K.
    Joshi, Rachit
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 194 - 201
  • [6] The influence of NH3-H2O-LiBr ternary working fluid on the performance and solution circulation in ammonia absorption refrigeration system
    Xu, Mengkai
    Li, Shuhong
    Jin, Zhenghao
    Jiang, Weixue
    Du, Kai
    APPLIED THERMAL ENGINEERING, 2023, 234
  • [7] Cuprophilicity?: The solid state structures of [Cu(NH3)Cl] and [Cu(NH3)2]Br.
    Wagner, M
    Margraf, G
    Lerner, HW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U163 - U163
  • [8] Analysis of thermodynamic performance in NH3/CO2 Cascade refrigeration system
    Duan Rui
    Cui Guomin
    Zhu Qunzhi
    ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 1484 - +
  • [9] EFFECT OF THE INTERFACE HEAT-EXCHANGER IN COMPOSITE NH3/H2O-H2O/LIBR ABSORPTION-REFRIGERATION SYSTEMS
    ROGDAKIS, ED
    ANTONOPOULOS, KA
    HEAT RECOVERY SYSTEMS & CHP, 1991, 11 (06): : 495 - 504
  • [10] NH3/H2O-LIBR AS WORKING FLUID FOR THE COMPRESSION ABSORPTION CYCLE
    AHLBY, L
    HODGETT, D
    RADERMACHER, R
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1993, 16 (04): : 265 - 273