Time-Resolved Noncontrast Magnetic Resonance Perfusion Imaging of Paraspinal Muscles

被引:1
|
作者
Miyazaki, Mitsue [1 ]
Yamamoto, Asako [2 ]
Malis, Vadim [1 ]
Statum, Sheronda [1 ,4 ]
Chung, Christine B. [1 ,4 ]
Sozanski, Jesse [3 ]
Bae, Won C. [1 ,4 ]
机构
[1] Univ Calif San Diego, Dept Radiol, La Jolla, CA 92093 USA
[2] Teikyo Univ, Dept Radiol, Sch Med, Tokyo, Japan
[3] Univ Calif San Diego, Dept Family Med, La Jolla, CA 92093 USA
[4] VA San Diego Healthcare Syst, Dept Radiol, San Diego, CA USA
基金
美国国家卫生研究院;
关键词
lumbar spine; low back; arterial spin labeling; exercise; blood flow; RECOVERY FAIR TECHNIQUE; CONTRAST-ENHANCED MRI; SKELETAL-MUSCLE; CEREBRAL-BLOOD; MYOCARDIAL-PERFUSION; RAT-KIDNEY; ARTERIAL; INVERSION; EXERCISE; ACUPUNCTURE;
D O I
10.1002/jmri.28123
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background While evaluation of blood perfusion in lumbar paraspinal muscles is of interest in low back pain, it has not been performed using noncontrast magnetic resonance (MR) techniques. Purpose To introduce a novel application of a time-resolved, noncontrast MR perfusion technique for paraspinal muscles and demonstrate effect of exercise on perfusion parameters. Study Type Longitudinal. Subjects Six healthy subjects (27-48 years old, two females) and two subjects with acute low back pain (46 and 65 years old females, one with diabetes/obesity). Field Strength/Sequence 3-T, MR perfusion sequence. Assessment Lumbar spines of healthy subjects were imaged axially at L3 level with a tag-on and tag-off alternating inversion recovery arterial spin labeling technique that suppresses background signal and acquires signal increase ratio (SIR) from the in-flow blood at varying inversion times (TI) from 0.12 seconds to 3.5 seconds. SIR vs. TI data were fit to determine the perfusion metrics of peak height (PH), time to peak (TTP), mean transit time, apparent muscle blood volume (MBV), and apparent muscle blood flow (MBF) in iliocostal, longissimus, and multifidus. Imaging was repeated immediately after healthy subjects performed a 20-minute walk, to determine the effect of exercise. Statistical Tests Repeated measures analysis of variance. Results SIR vs. TI data showed well-defined leading and trailing edges, with sharply increasing SIR to TI of approximately 500 msec subsiding quickly to near zero around TI of 1500 msec. After exercise, the mean SIR at every TI increased markedly, resulting in significantly higher PH, MBV, and MBF (each P < 0.001 and F > 28.9), and a lower TTP (P < 0.05, F = 4.5), regardless of the muscle. MBF increased 2- to 2.5-fold after exercise, similar to the expected increase in cardiac output, given the intensity of the exercise. Data Conclusions Feasibility of an MR perfusion technique for muscle perfusion imaging was demonstrated, successfully detecting significantly increased perfusion after exercise. Level of Evidence 1 Technical Efficacy Stage 1
引用
收藏
页码:1591 / 1599
页数:9
相关论文
共 50 条
  • [1] Quantitative perfusion imaging in magnetic resonance imaging
    Zoellner, F. G.
    Gaa, T.
    Zimmer, F.
    Ong, M. M.
    Riffel, P.
    Hausmann, D.
    Schoenberg, S. O.
    Weis, M.
    RADIOLOGE, 2016, 56 (02): : 113 - 123
  • [2] Magnetic resonance imaging evaluation of cervical paraspinal muscles in dropped head syndrome
    Toriumi, Kensuke
    Miyamoto, Hiroshi
    Ikeda, Terumasa
    Goto, Koji
    EUROPEAN SPINE JOURNAL, 2025, 34 (03) : 896 - 903
  • [3] "PINOT": Time-Resolved Parallel Magnetic Resonance Imaging With a Reduced Dynamic Field of View
    Hamilton, Lei Hou
    Fabregat, Javier Acebron
    Moratal, David
    Ramamurthy, Senthil
    Lerakis, Stamatios
    Parks, W. James
    Sallee, Denver, III
    Brummer, Marijn E.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) : 1062 - 1075
  • [4] Adult Tetralogy of Fallot Quantitative Assessment of Pulmonary Perfusion With Time-Resolved Three Dimensional Magnetic Resonance Angiography
    Tomasian, Anderanik
    Krishnam, Mayil S.
    Lohan, Derek G.
    Moghaddam, Abbas N.
    Finn, J. Paul
    INVESTIGATIVE RADIOLOGY, 2009, 44 (01) : 31 - 37
  • [5] Magnetic Resonance Imaging of Lung Perfusion
    Triphan, Simon M. F.
    Bauman, Grzegorz
    Konietzke, Philip O.
    Konietzke, Marilisa
    Wielpuetz, Mark
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (03) : 784 - 796
  • [6] Skeletal Muscle Microvascular Flow in Progressive Peripheral Artery Disease Assessment With Continuous Arterial Spin-Labeling Perfusion Magnetic Resonance Imaging
    Wu, Wen-Chau
    Mohler, Emile
    Ratcliffe, Sarah J.
    Wehrli, Felix W.
    Detre, John A.
    Floyd, Thomas F.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (25) : 2372 - 2377
  • [7] PILLAR: ParaspInaL muscLe segmentAtion pRoject - a comprehensive online resource to guide manual segmentation of paraspinal muscles from magnetic resonance imaging
    Anstruther, Meagan
    Rossini, Bianca
    Zhang, Tongwei
    Liang, Terrance
    Xiao, Yiming
    Fortin, Maryse
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [8] PILLAR: ParaspInaL muscLe segmentAtion pRoject - a comprehensive online resource to guide manual segmentation of paraspinal muscles from magnetic resonance imaging
    Meagan Anstruther
    Bianca Rossini
    Tongwei Zhang
    Terrance Liang
    Yiming Xiao
    Maryse Fortin
    BMC Musculoskeletal Disorders, 24
  • [9] Magnetic Resonance Imaging-Based Morphological Change of Paraspinal Muscles in Girls With Adolescent Idiopathic Scoliosis
    Yeung, Kwong Hang
    Man, Gene Chi Wai
    Shi, Lin
    Hui, Steve Cheuk Ngai
    Chiyanika, Chileka
    Tsz Ping Lam
    Ng, Bobby Kin Wah
    Cheng, Jack Chun Yiu
    Chu, Winnie Chiu Wing
    SPINE, 2019, 44 (19) : 1356 - 1363
  • [10] Myocardial perfusion imaging by magnetic resonance imaging
    Katherine C. Wu
    Current Cardiology Reports, 2003, 5 (1) : 63 - 68