Conductometric Immunosensor for Escherichia coli O157:H7 Detection Based on Polyaniline/Zinc Oxide (PANI/ZnO) Nanocomposite

被引:17
|
作者
Mutlaq, Sawsan [1 ]
Albiss, Borhan [2 ]
Al-Nabulsi, Anas A. [1 ]
Jaradat, Ziad W. [3 ]
Olaimat, Amin N. [4 ]
Khalifeh, Mohammad S. [5 ]
Osaili, Tareq [1 ,6 ]
Ayyash, Mutamed M. [7 ]
Holley, Richard A. [8 ]
机构
[1] Jordan Univ Sci & Technol, Dept Nutr & Food Technol, POB 3030, Irbid 22110, Jordan
[2] Jordan Univ Sci & Technol, Dept Appl Phys, Nanomat Lab, POB 3030, Irbid 22110, Jordan
[3] Jordan Univ Sci & Technol, Dept Biotechnol & Genet Engn, POB 3030, Irbid 22110, Jordan
[4] Hashemite Univ, Fac Appl Med Sci, Dept Clin Nutr & Dietet, POB 330127, Zarqa 13133, Jordan
[5] Jordan Univ Sci & Technol, Dept Basic Med Vet Sci, POB 3030, Irbid 22110, Jordan
[6] Univ Sharjah, Coll Hlth Sci, Dept Clin Nutr & Dietet, POB 27272, Sharjah, U Arab Emirates
[7] United Arab Emirates Univ UAEU, Coll Agr & Vet Med, Dept Food Sci, POB 15551, Al Ain, U Arab Emirates
[8] Univ Manitoba, Dept Food & Human Nutr Sci, Winnipeg, MB R3T 2N2, Canada
关键词
E. coli O157:H7; polyaniline; zinc oxide nanoparticles; immunosensor; antibody; GOLD NANOPARTICLES; SALMONELLA-TYPHIMURIUM; SENSITIVE DETECTION; POLYMER; BIOSENSOR; CAPTURE; MWCNT; AU;
D O I
10.3390/polym13193288
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
A conductometric immunosensor was developed for the detection of one of the most common foodborne pathogens, Escherichia coli O157:H7 (E. coli O157:H7), by conductometric sensing. The sensor was built based on a polyaniline/zinc oxide (PANI/ZnO) nanocomposite film spin-coated on a gold electrode. Then, it was modified with a monoclonal anti-E. coli O157:H7 antibody as a biorecognition element. The fabricated nanostructured sensor was able to quantify the pathogens under optimal detection conditions, within 30 min, and showed a good detection range from 10(1) to 10(4) CFU/mL for E. coli O157:H7 and a minimum detection limit of 4.8 CFU/mL in 0.1% peptone water. The sensor efficiency for detecting bacteria in food matrices was tested in ultra-heat-treated (UHT) skim milk. E. coli O157:H7 was detected at concentrations of 10(1) to 10(4) CFU/mL with a minimum detection limit of 13.9 CFU/mL. The novel sensor was simple, fast, highly sensitive with excellent specificity, and it had the potential for rapid sample processing. Moreover, this unique technique for bacterial detection could be applicable for food safety and quality control in the food sector as it offers highly reliable results and is able to quantify the target bacterium.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Detection of Escherichia coli O157:H7 in the beef marketed in Malaysia
    Radu, S
    Mutalib, SA
    Rusul, G
    Ahmad, Z
    Morigaki, T
    Asai, N
    Kim, YB
    Okuda, J
    Nishibuchi, M
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1998, 64 (03) : 1153 - 1156
  • [42] Multiplex PCR for detection of Escherichia coli O157:H7 in foods
    Barbora Vidová
    Eva Tóthová
    Ľuboslav Blahut
    Viera Horváthová
    Andrej Godány
    Biologia, 2011, 66 : 401 - 405
  • [43] Fabrication of a disposable biosensor for Escherichia coli O157:H7 detection
    Muhammad-Tahir, Z
    Alocilja, EC
    IEEE SENSORS JOURNAL, 2003, 3 (04) : 345 - 351
  • [44] Detection and characterization of the fimA gene of Escherichia coli O157:H7
    Li, BG
    Koch, WH
    Cebula, TA
    MOLECULAR AND CELLULAR PROBES, 1997, 11 (06) : 397 - 406
  • [45] DETECTION OF ESCHERICHIA-COLI O157/H7 BY MULTIPLEX PCR
    FRATAMICO, PM
    SACKITEY, SK
    WIEDMANN, M
    DENG, MY
    JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (08) : 2188 - 2191
  • [46] Modification of methods for detection of Escherichia coli O157:H7 on produce
    Kim, Se-Ri
    Yoon, Yohan
    Seo, Min-Kyoung
    Kim, Won-Il
    Shim, Won-Bo
    Chung, Duck Hwa
    Yun, Jong Chul
    Ryu, Kyoung Yul
    Kim, Byung-Seok
    FOOD SCIENCE AND BIOTECHNOLOGY, 2014, 23 (04) : 1349 - 1356
  • [47] A comprehensive review of detection methods for Escherichia coli O157:H7
    Bai, Zhuangzhuang
    Xu, Xianbao
    Wang, Cong
    Wang, Tan
    Sun, Chuanyu
    Liu, Shuangxi
    Li, Daoliang
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 152
  • [48] Detection of the viable but nonculturable state in Escherichia coli O157:H7
    Rigsbee, W
    Simpson, LM
    Oliver, JD
    JOURNAL OF FOOD SAFETY, 1997, 16 (04) : 255 - 262
  • [49] Recent Trends in the Detection of Pathogenic Escherichia coli O157: H7
    Wu, Si-Ying
    Hulme, John
    An, Seong Soo A.
    BIOCHIP JOURNAL, 2015, 9 (03) : 173 - 181
  • [50] Immunoliposome sandwich assay for the detection of Escherichia coli O157:H7
    Park, S
    Durst, RA
    ANALYTICAL BIOCHEMISTRY, 2000, 280 (01) : 151 - 158